Wastewater from any building sewer entering a public sewer, which is strictly domestic in nature but of high strength, will cause the user to be subject to a surcharge based on the following formula: Surcharge formula: C;sub§\sub; = (B c (B) + S c (S) + P c (P)) V u Where: | | | | |----|----|----| | C;sub§\sub; | = | A surcharge for wastewaters of excessive strength. | | B c | = | Operation and maintenance cost for treatment of unit of B.O.D., milligrams per liter. | | B | = | Concentration of B.O.D. from a user above a base level of two hundred (200) milligrams per liter. | | S c | = | Operation and maintenance cost for treatment of a unit of suspended solids, milligrams per liter. | | S | = | Concentration of suspended solids from a user above a base level of two hundred (200) milligrams per liter. | | P c | = | Operation and maintenance cost for treatment of a unit of any pollutant, milligrams per liter. | | P | = | Concentration of any pollutant from a user above a base level in milligrams per liter. The base level shall be determined by the average discharge of the pollutant (mg/l) by residential users. | | V u | = | Volume contribution from a user per unit of time, gallons per month. | The city shall take twenty-four-hour proportional composite samples of a user's sewerage discharge to determine concentration levels of B, S and P and to determine a pattern of surcharges. Thereafter, the city may periodically take additional samples for the purpose of adjusting the surcharges. The user may request additional sampling and testing and obtain same provided the user bears the expense.