The volume of wastewater from any building sewer which exceeds two (2) percent of the average daily flow of the sewer system and which is allowed to discharge the full volume to a public sewer will cause the user to be subject to a charge based on the following formula:
Charge formula:
C u = V C V
Where:
| | | | |----|----|----| | C u | = | A charge for a volume in excess of two (2) percent of the average daily flow of the sewer system. | | V c | = | Operation and maintenance cost for transportation and treatment of a unit of wastewater volume, gallons. | | V | = | Volume of wastewater from a user above two (2) percent of the average daily flow of the sewer system. |
The city shall determine the average daily flow from all users periodically and shall determine the average daily flow of the user by actual measurement and/or flow estimates to determine the charge for flow above two (2) percent of the sewer system average daily flow. The user may request actual measurements of his sewerage discharge at any time and obtain same, provided that user bears the expense.
History
(Code 1974, § 21-108(12))