--- title: Jasper Code of Ordinances, Sec. 34-73. Building standards for streams without established base flood elevations and/or floodway (A-zones) collection: local-codes id: local-code:jasper/code/34-73 cite_as: Jasper, Ga., Code of Ordinances § 34-73 canonical_url: https://georgiacommons.org/cities/jasper/code/34-73 md_url: https://georgiacommons.org/cities/jasper/code/34-73.md text_url: https://georgiacommons.org/cities/jasper/code/34-73/text source_url: https://library.municode.com/ga/jasper/codes/code_of_ordinances date: 2026-11-11 status: active jurisdiction: city:jasper jurisdiction_name: Jasper place_fips: "1341932" corpus_version: local-codes-jasper-e45d25ebc1fe publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/cities/jasper/code/~part-ii/~chapter-34/~article-iv.md previous: https://georgiacommons.org/cities/jasper/code/34-72.md next: https://georgiacommons.org/cities/jasper/code/34-74.md index: https://georgiacommons.org/cities/jasper.md branch: code edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:jasper/code/34-73@2026-11-11-e1949c6125 --- # Jasper Code of Ordinances, Sec. 34-73. Building standards for streams without established base flood elevations and/or floodway (A-zones) > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 34 - FLOOD DAMAGE PREVENTION / Article IV - PROVISIONS FOR FLOOD HAZARD REDUCTION Located within the areas of special flood hazard established in section 34-22, where streams exist, but no base flood data have been provided (A-zones), or where base flood data have been provided but a floodway has not been delineated, the following provisions apply: (1) When base flood elevation data or floodway data have not been provided in accordance with section 34-22, then the building official shall obtain, review, and reasonably utilize any scientific or historic base flood elevation and floodway data available from a federal, state, or other source, in order to administer the provisions of article IV. Only if data are not available from these sources, then the following provisions (2) and (3) shall apply: (2) No encroachments, including structures or fill material, shall be located within an area equal to the width of the stream or 20 feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in more than a one foot increase in flood levels during the occurrence of the base flood discharge. (3) In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three feet above the highest adjacent grade at the building site. (Note: Require the lowest floor to be elevated one foot above the estimated base flood elevation in A-zone areas where a limited detail study has been completed). Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of subsection 34-71(4) "elevated buildings". a. All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be elevated no less than three feet above the highest adjacent grade at the building site. The building official shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file. ## History (Ord. of 7-12-2010(2), Art. 4, § C)