All buffers required by this article shall conform to the following specifications:
(1) Buffer plan. Prior to development, a buffer plan shall be required to show the types and locations of all screening devices within a required buffer.
(2) Screening of service areas, etc. Landscaping within buffer areas shall be used to screen objectionable views or nuisances, such as parking and service areas, refuse containers, air conditioning units and transformers.
(3) Existing trees and plants. Existing on-site trees and shrub plants may be credited as meeting the requirements of this article if the enforcement officer determines that such plant materials achieve the purposes of this article.
(4) Buffer A design. Buffer A as required in the table in section 94-106(b) shall consist of plantings or a fence, wall (not otherwise part of a structure or accessory structure), or a berm, which meets the screening standards of subsection (7) of this section.
(h) Sterilization. All pipelines and all appurtenances including house service connections which have been exposed to contamination by reason of this construction shall be sterilized before being placed in service. Pipelines shall remain filled for a 24-hour period with a solution of water and HTH or chlorine in amounts equivalent to at least the following quantities for each 100 feet of pipe:
Pipe Diameter (in inches)
HTH
(ounces) 62 63 10 4 12 6 16 10
(1) Not less than one ounce of HTH shall be used, per 100 feet, for all mains, sizes two inches and smaller, the above quantities shall be increased if necessary to secure a chlorine residual of 50 parts per million after 24 hours. The developer shall obtain bacteriological analysis of samples of water taken from the distribution system which are satisfactory to the owner, before the lines will be accepted.
(2) Furnish all HTH or liquid chlorine required for sterilization. Furnish all equipment and labor required for the work, and provide for the bacteriological test. All chlorinated water shall be disposed in accordance with the rules of the state environmental protection division.
(3) Flushing. Upon completion of the sterilization, all mains and piping shall be thoroughly flushed before placing in service.
(i) Installation of pipelines. Pipe shall be installed with a minimum of four-foot cover, ditch line shall be on a straight even grade with no peeks or valleys. Sufficient excavation shall be made for pipe bells. Ditch bottom shall be fine graded. Ditch in rocky areas shall be undercut and the pipe bedded in at least six inches of crushed stone, gradation #67. Selected backfill consisting of finely divided earth, sand, stone dust, or crushed stone shall be placed and tamped about and over the pipe (in six inch layers) up to a height of at least 12 inches above the top of the pipe barrel. Before replacing the remaining backfill on PVC pipe, detectable marking tape, imprinted with the words "Buried Water," as manufactured by Reef Industries, Inc., Alien Systems, Inc., or equal shall be placed in the ditch for the entire length of pipe line installed. Tape for pipe smaller than six inches shall be two inches in width, tape for pipe six inches and larger shall be six inches in width. General backfill material may be used to fill the remainder of the ditch except that no rock will be permitted to be mixed with backfill material. Backfill material shall be placed in six-inch layers with each layer thoroughly compacted with heavy-duty tampers. Wheel loading will not be permitted until the pipe has a minimum cover of 36 inches. All dead-end water lines shall require a flush assembly at the dead-end valve. (See attachment 82-493(i) 1-1).
History
(Code 1979, ch. 47, § II; Ord. of 4-7-2014(1))
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.