73-6.2.1. Character Overlay District (COD).

About this text

  • As published by Municode, current through 2026-02-09
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

A. General.

1. Intent. The intent of the Character Overlay District (COD) is to set a standard for the design, form and use of properties within the identified corridor that is reflective of the character of the area. The Overlay is intended to support and protect the development and redevelopment in the district all the while ensuring consistency and compatibility with the respective character of the properties. These criteria are intended to elicit high quality materials, enhanced pedestrian experience, an appropriate scale, and a development pattern that effectively implements the City's planning and visioning documents.

2. Prohibited Uses. The following uses are prohibited in the COD, regardless of whether the underlying zoning district allows the use:

a. Animal Boarding.

b. All "other financial services (check cashing, pawnshop, other)".

c. Equipment and material storage.

d. Extended stay lodging.

e. Mobile food vendors (defined herein as soliciting to the general public).

f. Tattoo parlors.

g. Vape shop or smoke store.

h. Vehicle equipment sales, service.

i. Vehicle maintenance and repair, minor.

j. Vehicle maintenance and repair, major.

k. All "other wireless facilities".

l. Liquor Stores.

m. Gas Stations & Convenience Stores.

A. Applicability.

1. Any work proposed that is visible from the street, facing streets, facing main parking lots, and adjacent to, or visible from required open spaces, unless otherwise noted.

B. Exemptions.

1. An Overlay Approval Certificate (OAC) is not required if the work to be performed falls within the following:

a. General exterior maintenance or minor, in-kind repairs;

b. Any activity that is not visible from a public right-of-way, with the exception of relocation or demolition;

c. Items listed below:

i. Paved pathways less than five (5) feet wide and all sidewalks on the public right-of-way;

ii. Interior changes that do not affect the exterior of the building;

iii. The addition, modification, or removal of any vegetation, including specimen trees;

iv. The temporary boarding of openings that will not exceed 60 days; and/or

v. Replacement or installation of new fencing or screens.

C. Residential Building Design Standards.

1. The Mayor and Board of Aldermen will review the OAC application for consistency and compatibility with the adjacent and surrounding properties to ensure that the integrity of the proposed application is appropriate for the character area.

D. Non-Residential Building Design Standards.

1. The Mayor and Board of Aldermen will review the OAC application for consistency and compatibility with the adjacent and surrounding properties to ensure that the integrity of the proposed application is appropriate for the character area.

E. Review Process.

1. Prior to the submittal of an application for an OAC that will require review by the Mayor and Board of Aldermen, the applicant is required to participate in a pre-application meeting with the COD Committee.

2. If a request for an OAC is determined to necessitate review by the Planning and Zoning Commission (i.e. rezone, variance, etc.), the applicant may apply for an OAC and a zoning request concurrently.

3. Following review of the OAC application for completeness by staff, the applicant shall follow the process as outlined below:

a. The applicant will obtain a public notice sign from the Development Department.

b. No less than 15 days prior to the scheduled public hearing the applicant must post the public notice sign on the primary road frontage of the property in public view.

c. The applicant or his/her representative shall attend the scheduled public hearing and present details of their application to the Mayor and Board of Aldermen for consideration.

F. Supplemental Review Guidelines.

1. Mayor and Board may utilize any of the following residential and non-residential guidelines listed below as well as any other guidelines within the Code of Ordinances and/or other Boards and Commissions guidelines or recommendations, where applicable. For properties that are determined to be 50 years or older, the Mayor and Board will utilize guidelines established and set forth in Acworth's Local "Design Guidelines" for historic districts as adopted by the City of Acworth's Historic Preservation Commission and/or the United States Secretary of the Interior's Standards for the Treatment of Historic Properties with Guidelines for Preserving, Rehabilitating, Restoring & Reconstructing Historic Buildings.

Residential Building Design Standards (suggestions).

Floor area minimum in the COD shall be reduced to 1,000 square feet.

Exterior Finish Materials.

a. Exterior building materials shall be primarily brick, stone, other masonry, glass, wood, or cementitious fiberboard. Other materials such as vinyl may be used only as accent and trim materials. Masonry shall be unpainted.

b. All exposed foundation walls on all sides of the building shall be faced with brick, stone, or marble.

c. Metal shall be permitted only as metal split seam roofing or as an architectural accent comprising a maximum often percent (10%) of any one facade. Acceptable metal materials are limited to architectural metal panels, architectural metal cladding, metal mesh, and perforated metal. Examples of metal materials not permitted include but are not limited to stock PEMB metal skins commonly referred to as 'R-panel' and sheet metal systems with exposed fasteners, except as required for perforated metal.

Architectural Guidelines.

d. Private outdoor space:

i. Front porch (minimum 30 square feet in area).

ii. Front-facing balcony (minimum 50 square feet in area).

iii. Rear terrace (minimum 100 square feet in area).

iv. Rooftop terrace (minimum 150 square feet in area).

v. Private yard space with at least one tree (minimum 150 square feet in area).

e. Architectural projection:

i. Projection window (bay or bow).

ii. Turret.

iii. Covered balcony or porch.

f. Roof element:

i. Dormers.

ii. Front gable or pediment.

iii. Rooftop terrace.

iv. Varied gable system.

v. Cornice detailing.

g. Unit or façade.

i. Change in brick/stone color or a change in masonry material.

ii. Change in window composition.

iii. Projection or recess of an architectural feature that is a minimum of 5 feet deep or 15 feet tall (used to distinguish and separate facades vertically because of the significance of the projection).

h. Recessed Window Systems. Window systems recessed from the façade of the building a minimum of one and three-quarters (1.75) inches. This reveal shall be accomplished through the design of the window casing reveals and frames.

Non-Residential Building Design Standards (suggestions).

Exterior Finish Materials.

a. Primary Building Materials.

i. Primary building materials shall be used on at least 70% of any building façade, calculated on the basis of each individual façade.

ii. Primary building materials include unpainted brick, including full-depth and halfdepth masonry brick; stone, including unpainted natural stone, unpainted cast stone having the appearance of natural stone; and unpainted terracotta.

b. Secondary Building Materials.

i. Secondary building materials may be used on up to 30% of any exterior building façade, calculated on the basis of each individual façade.

ii. Secondary building materials include wood, including natural wood or cement-based artificial wood siding; shingles, including wood or cement-based shakes and shingle.

c. Other Standards.

i. Building materials, other than those expressly identified in this Section, may be used on up to ten percent (10%) of any exterior building façade, provided they have not been prohibited by this Section.

ii. Material proportion calculations shall not include building foundations, window systems, and doors. Proportions are calculated on the basis of each individual façade.

iii. Materials shall continue around the corner of the building onto façades not visible from the public street a minimum depth of one (1) architectural bay.

iv. Prohibited Materials. Synthetic stucco, concrete masonry units (CMU), and vinyl are not permitted as exterior finish materials.

v. Building façades shall be constructed of no more than three (3) primary materials and/or colors. Additional materials may be used as secondary, trim, or accent materials.

vi. Awnings. Plastic and vinyl awnings are prohibited. Materials repurposed into textiles for use on an awning is prohibited.

2. Building Articulation on Street Facing Facades. The ground story of non-residential facades fronting Main Street may contain the following elements as illustrated in Image 6.2.1.C.3 below.

a. Cornice/Articulated Floor Line. The cornice visually separates one floor from the adjacent floor(s). The cornice can be articulated with a change of color, pattern, or material.

b. Sign Board. A sign board shall be an area between the cornice and window system where a wall sign is placed. The sign board shall be a minimum of two (2) feet in height and shall extend the width of each architectural bay.

c. Transom. Transoms are horizontally articulated windows located below the sign board.

The window system shall extend the full width of the architectural bay or tenant space but may be separated by mullions and muntins consistent with the design aesthetic. Grilles are prohibited.

d. Recessed Entry. Recessed entries are important to the retail experience to protect the users from inclement weather, increase the amount of space in which to display merchandise, and to ease the transition of users to and from the public realm. Entryways shall be recessed from the plane of the shopfront façade a minimum of three (3) feet.

e. Display Window. Display windows provide frames for retail users to display merchandise and contribute to the active and vibrant character along the historic street front. Display windows shall not be separated with mullions, muntins, or grilles.

f. Bulkhead. Bulkheads shall be a minimum of 18 inches in height and shall extend the full length of the architectural bay or tenant space.

g. Fenestration. Fenestration proportions shall comply with standards in this Section Grilles, other faux features, and metal shopfront window systems are prohibited.

3. Wall Projections. In order to avoid large expanses of flat (one-dimensional) exterior walls along sidewalks, building façades over 50 feet in length along a street may incorporate wall projections or recesses a minimum of 12 inches in depth. The combined length of such recesses and projections shall constitute at least 20% of the total façade length along the public street.

4. Vertical Divisions. Each structure may provide a minimum of one of the following to divide the façade into vertical divisions at increments no greater than 100 feet as measured along the base of the façade.

a. A change of façade material and window system from grade to roof; or

b. Change of building height of at least one story; or

c. A change in façade composition and/or architectural style from grade to roof; or

d. An open space or pedestrian passage with a minimum width often (10) feet and a minimum depth of 30 feet.

e. Similar means intended to convey the impression of separate buildings.

f. Change in color alone, window system alone, or setback alone, do not satisfy this requirement.

5. Rooflines. Building roof lines along street-facing façades shall change at least once every 200 feet of façade length. This change shall occur for a minimum length of 20 feet and be accomplished through at least one of the following:

a. A change of roof parapet wall height and material.

b. A change of roof cornice design.

c. A change in the number of stories.

d. A change in roof-shape.

6. Blank Walls. Blank wall area applies to ground and upper story façades visible from a street (not including an alley) or open space.

a. Blank wall area is measured in linear feet applied in both vertical and horizontal directions.

b. There shall be no more than 20 feet of blank wall area.

c. Blank wall area can be broken up or interrupted to meet these provisions with any one of the following interventions:

i. Fenestration.

ii. Substantial material change. Changing or alternating paint colors alone does not constitute a material change.

iii. Façade articulation greater than 12 inches in depth.

iv. Patterns and designs articulated with building materials.

v. Vertical green walls, made of landscaped material specified for vertical, climbing growth.

d. Where balconies are incorporated into the building design, they shall be integral to the façade.

e. Balconies on stepped-back stories may be independently secured, extending from the façade as a cantilever.

f. Juliet balconies are prohibited.

7. Window Systems.

a. A minimum of 50% of commercial façades and 25% of residential facades shall be covered with fenestration. Fenestration percentage is calculated based on façade area and by floor.

The façade area used to determine fenestration is measured from the top of the finished door to the top of the finished floor above or top of a roof parapet.

b. Fenestration requirements apply to façades that abut a public or private street (not including an alley), or a required open space.

c. Glass used to satisfy fenestration requirements shall be unpainted, shall have a transparency (visible light transmission) higher than 70 percent (70%) and shall have an external reflectance of less than 15 percent (15%). Transparency and external light reflectance shall be established using the manufacturer's specifications.

d. Glazed doors, window frames, sashes, mullions, and similar features that are integral to the window system count towards fenestration requirements. Opaque doors and windows do not.

e. No shades, blinds, or other coverings are permitted on the ground floor fenestration of any non-residential building.

f. Grilles, inoperable shutters, and other faux window treatments are prohibited.

g. Window systems shall be recessed from the façade of the building a minimum of three (3) inches. This reveal shall be accomplished through the design of the window casing reveals and frames.

Image 6.2.1.C.3.-Building Articulation Features Image 6.2.1.C.7-Blank Wall Areas Image 6.2.1.C.9.-Fenestration Calculations 73-6.3 Other Districts.