Sec. 47-124. R-2 Residential District (single-family dwelling district).

About this text

  • As published by Municode, current through 2026-08-20
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Scope and intent. Regulations set forth in this section are the R-2 district regulations. The R-2 district is intended to provide areas for higher density single-family residential uses.

(b) Use regulations. Within the R-2 district, land and structures shall be used in accordance with the Table of Permitted Uses. Any use not specifically designated as permitted shall be prohibited.

(c) Development standards.

(1) Height regulations: buildings shall not exceed a height of 35 feet.

(2) Front yard setback: 20 feet.

(3) Side yard setback: Eight feet.

(4) Rear yard setback: 20 feet.

(5) Minimum lot area: 7,000 square feet.

(6) Minimum lot width at building line on non-cul-de-sac lots: 60 feet.

(7) Minimum lot frontage: 35 feet adjoining a street.

(8) Minimum heated floor area of primary structure: 1,200 square feet.

(9) Metal panel exterior: A metal panel exterior finish product shall not be allowed on metal buildings exceeding 150 square feet in gross floor area constructed or placed on lots within the R-2 district.

(10) Gable or hip roofs: Gable or hip roofs shall have a minimum roof pitch of 5:12. Both gable and hip roofs shall provide overhanging eaves on all sides that extend a minimum of one foot beyond the building wall.

(11) Front building facade: The front building facade of all principal buildings shall be oriented toward street fronts or adjacent arterial street fronts.

(12) Minimum open space requirements: Proposed developments consisting of more than five acres shall reserve a minimum of 20 percent of the gross acreage of the site as open space with common areas provided.

(13) Optional density bonus: Proposed developments may contain lots with minimum areas of 5,000 square feet if one of the following additional criteria are met:

a. Submittal of an affidavit certifying that all units will meet certification standards of the EarthCraft House certification program or will be LEED certified homes.

b. Submittal of an affidavit certifying that all units will be clad with exterior finishes of brick, stone, or board and batten on 67 percent or more of wall surfaces and 100 percent architectural roofing shingles.

History

The history line the source prints at the end of the section.

(Min. of 11-10-2016, § 7.2; Ord. No. 2018-0001, § 3, 4-12-2018; Ord. No. 2019-0009, § 2, 11-14-2019; Ord. No. 2026-005, § 1, 5-14-2026)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.