2. Where a sign consists of individual letters, words or symbols attached to a surface, building, canopy, awning, wall or window and all such elements are located in the same plane, the sign area shall be the area of the smallest rectangle which completely encompasses all such letters, words or symbols and any accompanying background of a color different than the natural color of the wall. Where such sign includes multiple words, each word located in the same plane shall be computed separately Commentary: Channel letter signs, mounted logos, and similar devices are treated differently than signs in cabinets – the wall area between multiple elements does not count as sign area.

3. On all signs, like stanchion, monument, or billboards, with two identical sign faces, only one side of the sign face is used for computation purposes of the sign area unless the angle at which the two sign faces are installed exceed 60 degrees. If the two faces of a double-faced sign are of unequal area, the area of the sign shall be taken as the area of the larger face.

Commentary: It is presumed that where sign faces are placed less than 60 degrees apart, both faces are not readable from any one point.

4. The entire surface area of a multi‐tenant sign that depicts the names of the individual tenants shall count toward the total aggregate area of the sign.

B. Location

1. All signs shall be located outside the public right‐of‐way.

2. Signs shall be located in a way that there is at every intersection and driveway clear sight distance for pedestrians, cyclists, and motorists traveling on or entering any street, road, or highway.

3. On any corner lot, signs shall not be located within the sight distance triangle, the area of which is described below.

a. Streets and roads. The area formed at a corner intersection of two public roads and streets whose two sides are 25 feet, measured along the right-of-way line of the two roads/streets, and whose third side is a line connecting the two sides.

b. Driveways/alleys. The area formed at a corner intersection of public right-of-way and a driveway, whose two sides are 15 feet, measured along the right-of-way line of the street and the edge of the driveway, and whose third side is a line connecting the two sides.

C. Height The height of a sign shall be computed as the distance from the base of the sign at a computed grade to the top of the highest attached component of the sign (including the sign face, sign structure, or any other appurtenance). The computed grade shall be the elevation of the nearest point to the proposed sign location of the crown of the nearest public street providing access; or the grade of the land at the principal entrance to the principal structure on the lot, whichever is higher.

D. Illumination

1. Signs may be illuminated from within or from an external source, but such illumination shall be in a manner which avoids glare or reflection which in any way interferes with traffic safety. The illumination of signs in which the light source is concealed or contained within the structure itself and which becomes visible in darkness by shining through a translucent surface shall not exceed 12-foot candles of incident light measured at a distance of ten feet from such structures.

2. Signs illuminated by flood lights, spotlights or gooseneck reflectors shall be positioned in such a manner that none of the light spills over onto adjoining property or glares or shines into the eyes of motorists or pedestrians.

3. Sign lighting shall not be detrimental to adjacent residential property. Property directly across a public right of way shall be considered adjacent property. Unless otherwise permitted within this Ordinance, signs shall not be illuminated by moving lights, flickering lights, or a string of lights placed around the sign.

4. No electronic message sign or LED sign shall be illuminated at a density of greater than 12-foot-candles measured from the nearest point of any highway or public road.

All such signs shall be equipped with a dimmer control and or a photocell which shall consistently monitor ambient light conditions and adjust sign brightness accordingly.

E. Maintenance. All signs regulated by this Article shall be kept in good condition and not show signs of deterioration, dilapidation, or neglect as described below and be clean, neatly painted, and free from all electrical and mechanical hazards, including, but not limited to, faulty wiring and loose connections, and the premises surrounding same shall be maintained by the owner thereof in a sanitary and inoffensive condition, free and clear of all weeds, rubbish, and debris. A sign which has any of the following characteristics shall be considered dilapidated or deteriorated:

1. elements of the surface or background cannot be seen as viewed from the normal viewing distance, where portions of the finished material or paint flaked, broken off, or missing, or otherwise not in harmony with the rest of the surface;

2. the structural support or frame members are visibly bent, broken, dented or torn;

3. where the panel is visibly cracked, or materials are disintegrating in such a way as to constitute an unsightly or harmful condition;

4. the sign or its elements are twisted or leaning or at angles other than those at which it was originally erected such as a result of a failure of a structural support; or

5. the message or wording can no longer be clearly read under normal viewing conditions.

Sec. 303-5 Construction Standards All signs shall conform with O.C.G.A. § 32-6-75(9) (the Georgia Outdoor Advertising Control Act) and shall also meet the requirements below.

A. Wind pressure and dead load requirements. All freestanding (monument, stanchion) signs and billboards shall be designed and constructed to withstand the minimum wind load pressures and dead loads as specified in the International Building Code (IBC).

B. Electrical. Electrical load calculations and wiring plan must be in accordance with NFPA 70 and other documents, if required; all signs must bear the "U.L." label.

C. Materials. Signs shall be constructed of permanent and durable materials and permanently affixed to the ground or building except for temporary signs.

D. Surface of signs. All signs shall have a smooth surface, and no nails, tacks, or wires shall be permitted to protrude therefrom, except electrical reflectors and devices which may extend over the top and in front of the advertising structures.

E. Moveable parts. Chains or hinges shall securely fasten any movable part of any sign or billboard.

Sec. 303-6 Standards by Sign Type Upon issuance of a sign permit in accordance with Sec. 303-3 [Sign Permits and Procedures], the following signs shall be allowed subject to the following requirements.

A. Awning sign: A sign which is part of a fabric or other non‐structural awning.

1. The sign shall be flat against the surface of the awning.

2. The awning containing the sign shall maintain a clearance of 8’ above a public right‐ of‐way, sidewalk, or required front yard.

3. The sign shall not be closer than two feet, measured in horizontal distance, from the curb line of any street

4. Any fabric awning valance may not extend more than one foot below the rigid mount of the awning.

5. The area of all permitted awning signs shall be included in the area of permitted number of wall signs and permitted as wall sign face area.

B. Canopy sign: A sign imposed or painted upon any permanent roof-like structure projecting from a building. The canopy’s purpose most often is to shield pedestrians from the weather and is placed over walkways or entrances to buildings, etc.

1. The sign area shall not exceed 10 % of the largest vertical surface of the canopy.

2. In no case shall the sign extend beyond the vertical edge of the canopy to which it is attached.

C. Electronic message sign: A sign or portion thereof which results in the illuminated display of messages or information by the use of a matrix of electric lams (e.g., digital, LED or similar or refined display technology), movable discs, movable panels, light apertures, or other methods, which allow the message change to be actuated by a control mechanism rather than manually changing the message and which changes the message more often than twice daily.)

1. Displayed copy shall not be animated, blinking, chasing, flashing, or have other moving effects.

2. This provision shall not restrict the copy from merely changing from one message to another without any special effects.

3. Electronic changeable message signs can be located on stanchion signs, monument signs and shall not exceed 50 square feet or 25 percent of existing allowable sign area, whichever is more restrictive. Such signs could also be allowed on billboards exceeding the dimensions of 50 sq. ft. and 25 percent of existing allowable sign area, whichever is more restrictive as long as other local billboard and State billboard requirements are met.

4. Each message shall remain fixed for at least 15 seconds. Within the City of Flemington, the message shall remain fixed for at least 15 minutes.

5. The transition from one message to another shall occur in two (2) seconds or less.

6. The transition shall not occur with any special effects such as: swiping, fading, or any other special effect transition method.

7. The illumination of an electronic message sign shall not exceed 12 foot-candles as measured from the nearest point of the highway or public road. All such signs shall be equipped with a dimmer control and a photocell which shall constantly monitor ambient light conditions and adjust sign brightness accordingly.

8. A certified statement of a structural engineer that the footing of the sign is adequate to securely anchor the sign into place.

9. All changeable electronic variable message signs shall be distanced at least 200 feet from any of the following, as measured from the sign to the property line:

a. Residentially used properties

b. Residentially zoned properties

c. Structures that are not residentially zoned, but are residentially used

d. Undeveloped residential properties

10. Changeable electronic variable message signs shall include a default designed to freeze a display in one still position if a malfunction occurs.

11. Within the City of Hinesville, any changeable electronic variable message sign shall not be permitted within the Downtown Redevelopment Overlay District Area as defined in this Ordinance, excluding the following corridors within said district: General Screven Way, Oglethorpe Highway, and General Stewart Way.

D. Freestanding sign: A sign having its own supporting structure independent of any building.

There are three types of this sign: stanchion, monument and billboard. No portion of any freestanding sign (monument, stanchion, billboard) shall be less than ten (10) feet off any street right-of-way unless exempted by this article.

1. Stanchion sign. No stanchion sign shall be nearer than 25 feet to any other freestanding sign. A sign which is six square feet or more in area shall not be closer than 75 feet to any other sign which is six square feet or more in size. Corner, double frontage lots shall be allowed a secondary stanchion sign on the secondary frontage.

Secondary freestanding signs shall not be more than half the height and one half the sign area of the principal freestanding sign.

2. Monument sign. The base shall be as wide as or wider than the sign body. No monument sign shall be nearer than 25 feet to any other freestanding sign. A sign which is six square feet or more in area shall not be closer than 75 feet to any other sign which is six square feet or more in size. Corner, double frontage lots shall be allowed a secondary monument sign on the secondary frontage. Secondary freestanding signs shall not be more than half the height and one half the sign area of the principal freestanding sign.

3. Billboard. Billboards shall only be permitted on the interstate highway and the state highway system of Georgia. Billboards shall meet all federal and state requirements (O.C.G.A. 32-6-70 et seq) necessary to obtain a permit under the Georgia Outdoor Advertising Control Act. Furthermore, billboards shall be in compliance with the regulations of this article.

a. No billboard shall be located within one thousand (1,000) ft. in any direction (radius) of any other billboard. Furthermore, no billboard shall be located within five hundred (500) ft. in any direction from a public park, public playground, public recreation area, public forest, marshland, scenic area, cemetery, or historic site.

b. Billboards along the interstate shall be a minimum of ten (10) feet in height above the highest point of pavement; however, cannot exceed seventy (70) feet in height above the center of the interstate. Two (2) signs in the same location, whether back-to-back or in a “V” formation shall be the same height above the surface of the Interstate.

c. Billboards located along non-interstate highways shall not be more than 32 feet in height. This distance shall be measured from the highest point of paved or unpaved highway to the highest point of the billboard. Two signs in the same location, whether back-to-back or in a "V" formation, shall be the same height above the surface of the highway.

d. No billboard shall be permitted which, because of its size, shape, or location, may obscure or obstruct vehicular or pedestrian traffic or be confused with any authorized traffic control sign, signal, or device.

e. Billboards can only be installed on undeveloped property; zoning districts that allow billboards are shown in Table 303.9. However, an existing billboard on a parcel shall not preclude businesses on the same parcel to be able to have a stanchion or monument sign.

f. All billboards adjacent to an interstate shall not exceed outside measurements of twelve (12) feet in height and fifty (50) feet in length per sign face, including trim.

g. All billboards adjacent to non-interstate highways shall not exceed three hundred seventy-eight (378) square feet for one sign face. However, a two-faced billboard cannot exceed 600 sq. ft.

h. No more than one (1) sign face shall face in any one (1) direction per location.

This means that there shall be a maximum of two (2) sign faces per location to allow back-to-back signs or signs in a "V" formation.

i. Billboard signs may have an apron directly beneath the face of the signs which shall not be used for advertising purposes and shall only be permitted to display the agency holding the permit and the permit number. The aprons shall be uniform in size, measuring three (3) feet in height and forty-five (45) feet in length.

j. No part of any billboard shall be installed closer than 10 ft. from the public rightof-way, in or over any public property, or any utility or drainage easement, or upon telephone or utility poles, or natural features such as trees and rocks.

k. No billboard shall be erected or maintained upon or above the roof of any building structure.

l. All billboards shall be constructed entirely out of steel, shall be supported by a single steel pole (monopole) and shall have a steel face on all facings.

m. All billboard construction shall meet applicable building codes and all signs shall always be kept in good structural condition and well-painted.

E. Projecting sign: A sign forming an angle with a building which extends from the building and is supported by the building.

1. The sign shall maintain a clearance of 12 feet above a sidewalk and shall not extend nearer the curb line than one (1) foot

2. No projecting sign shall be permitted which, because of its size, shape, or location, may obscure or obstruct vehicular or pedestrian traffic or be confused with any authorized traffic control sign, signal, or device.

3. Only one sign shall be permitted per establishment.

4. This type of sign shall count towards the wall signage allowance.

F. Gas station/fuel center sign: In addition to all the principal building signage, the following signage shall be allowed on a gas station/fuel center canopy.

1. One canopy sign shall be permitted on each side of a freestanding gas canopy. Such sign shall not cover more than ten (10) percent of the fascia of the freestanding canopy where the sign is located upon and be no larger in sign face area than nine (9) square feet, whichever is less. These signs shall be in addition to any wall and monument sign in relation to the adjunct store building.

2. Additionally, refer to subsection L below and Sec. 303-8 [Signs Allowed in All Districts without a Sign Permit] for gas pump signage.

G. Common development entrance sign (Apartments, office parks, residential subdivisions, condos, and townhouses etc.)

Up to two stanchion or monument signs may be placed at each entrance to identify the subdivision or multi-family development.

Signs shall be incorporated into a permanent landscape feature such as a wall or masonry columns. Said structure shall be made of

durable materials including, but not limited to: brick, stone, wrought iron, or composite materials, but in no case will a wood sign be

permitted. Columns may be incorporated into the signage with a maximum allowable height of eight (8) feet. Sign(s) must be located outside the ROW. Additional requirements for these signs are included in Table 303.9.

H. Wall sign: Any sign which is permanently attached to or painted on any wall, mansard, or parapet of a building. A sign forming on an awning or a canopy shall also be considered a wall sign for purposes of this Article.

1. A wall sign shall not extend more than twelve (12) inches from the wall of the building.

2. If a wall sign is attached to a wall at a height of less than ten feet above any sidewalk or walking path, then that wall sign shall not extend from the surface of the wall more than eight inches.

3. Wall signs shall not cover wholly or partially any wall opening, nor project beyond the ends or top of the wall to which it is attached.

4. The sign may not extend beyond the edges of the wall to which it is attached, except when the sign is contiguous on two adjacent walls of the same building. The total sign area shall be the sum of all signs affixed parallel to the wall not protruding more than eight (8) inches from the wall if located less than ten (10) feet off the ground., signs on awnings or canopies, door signs, signs on the lower slopes of roofs or canopy roofs, signs on parapets, suspended signs, projecting signs and all similar other signs shall be considered wall signs concerning sign area regulations – see window signs.

I. Mansard sign: A sign imposed, mounted, or painted on a steeply roof-like façade architecturally similar to a building wall. This type of sign shall count towards the wall signage allowance. Mansard Signs are considered wall signs concerning sign area regulations.

J. Parapet sign: A sign imposed, mounted or painted on, and not extending above the top of the extension, false front or wall above the roofline. This type of sign shall count towards the wall signage allowance.

K. Temporary sign:

1. Applicable in all jurisdictions except Flemington and Hinesville:

Any sign which is intended for temporary use and not permanently mounted. The sign shall only be permitted for a temporary period. The following temporary signs are allowed and require a permit and shall meet the requirements below and in Table 303.9:

a. Temporary Subdivision Sign: One temporary subdivision sign structure per development.

b. Windblown Sign: Pennants, flags, balloons, etc., which act to attract attention to an area shall be permitted only in commercial and industrial districts.

c. Banner Sign: A lightweight fabric or similar material which is either suspended between poles or mounted against a rigid surface like a wall, roof, or similar structure shall be permitted only in commercial and industrial districts.

d. Temporary Stanchion Sign: Only permitted in commercial districts.

2. Applicable in Flemington and Hinesville only

a. The following temporary signs are allowed and require a permit, are only allowed for a limited period, and shall meet the requirements below and in Table 303.9:

Temporary Subdivision or Construction Sign: One temporary subdivision sign structure allowed per development.

b. Windblown Sign: Pennants, flags, balloons, etc., which act to attract attention to an area shall be permitted only in commercial and industrial districts.

c. Banner Sign: A lightweight fabric or similar material which is either suspended between poles or mounted against a rigid surface like a wall, roof, or similar structure shall be permitted only in commercial and industrial districts.

d. Temporary Stanchion Sign: Only permitted in commercial districts.

L. Vending machines, automatic tellers machines and gasoline pump kiosk signs: Signs that display the name, trademark or logo of the company or brand or prices provided the display is an integral part of the vending machine, automatic teller machine or gas pump.

Such signs shall be an integral part of the vending machine, automatic teller, etc. However, in no case shall these signs exceed 32 sq. ft. See also Sec. 303-8 [Signs Allowed in All Districts with a Sign Permit].

Sec. 303-7 Prohibited Signs The following signs or characteristics of signs shall be prohibited:

A. Roof signs. A sign that is mounted on, applied to, or otherwise structurally supported by the roof of the building.

B. Vehicular signs and electronically generated signs on vehicles. A "vehicular sign” includes any name, insignia, logo, or sign attached to, mounted on, pasted on, painted, drawn on, or otherwise affixed to any vehicle (motorized or drawn) or conveyance placed, parked, or maintained at one particular location for the primary purpose of advertising or promoting a product or service, or directing people to a business or activity. For purposes of this section, the length of time a vehicle is present at one particular location shall raise a presumption that its primary purpose is to serve as a vehicular sign, except where the business has no reasonable alternative location on the site to park the vehicle. This definition shall not apply to the following:

1. When such vehicles are in motion or are "actively" used to transport persons, goods, or services in the normal course of business (i.e. delivery service, construction trailer, etc.), or to portable signs as defined herein. However, electronic signs shall be prohibited.

2. When such vehicles are parked in an inconspicuous area.

3. When such vehicles are actively being used for storage of construction materials for, and on the same lot with a bona fide construction project for which building and other applicable permits have been issued and where construction is underway and provided said vehicles or conveyance are located within designated storage areas.

C. Fluctuating/animated/or motion signs. Any attraction device or signs which flashes, blinks, is animated, giving the optical illusion of action, motion, or color changes, or has any change in appearance, meaning not being static and fixed, is scrolling and/or fluctuates in light intensity (e.g., running lights) shall be prohibited.

D. Rotating or revolving signs. Any sign that rotates around its axis or revolves around an object.

E. Signs emitting sound. Any sign or attachment thereto capable of producing sound.

F. Inflatable signs. Signs that are either expanded to its full dimensions or supported by gases contained within the sign, or sign parts, at a pressure greater than atmospheric pressure if larger than 5 ft in height and 4 ft. in width.

G. Dilapidated or damaged signs. A sign that has missing or broken panels, broken or damaged supports or frame, or otherwise displays inadequate maintenance, dilapidation, obsolescence or abandonment. See also Sec. 303-12 [Removal of Signs].

H. Signs constituting traffic hazards

1. Any sign which constitutes a hazard to traffic including, but not limited to, signs located within the sight distance triangle of an intersection.

2. Signs imitating warning signals are prohibited. No sign shall display lights resembling the flashing lights customarily used in traffic signals or in police, fire, ambulance, or rescue vehicles, regardless of the color; nor shall any signs use the words, slogans, dimensional shape and size, or colors of governmental traffic signs.

3. Signs shall not closely resemble or approximate a shape, form and color of official traffic signs, signals, or devices.

I. Obscene signs. Signs which contain words, pictures, or statements which are obscene, as defined by O.C.G.A § 16-12-80.

J. Portable signs. Any sign not permanently attached to the ground or other permanent structure designed to be moved easily, including, but not limited to, mobile signs, trailer signs, and A-frame/sandwich board signs. This notwithstanding, one (1) A-frame/sandwich board sign may be permitted per business if the height does not exceed 4 ft., does not create a hindrance on any public sidewalk and is taken inside during inclement weather and when the establishment is not open.

K. Private signs on public property. Such sign means an illegal sign posted on a utility pole, street sign, or other street furniture; or any other sign placed within a public right of way or public property or on private property such that it is visible from a public right of way or public property. It generally has less than six (6) square feet or less of advertising area.

It can be made of any material and is often tacked, nailed, posted, pasted, glued or otherwise attached to trees, poles, fences or other objects.

Sec. 303-8 Signs Allowed in All Districts without a Sign Permit Applicable in All Jurisdictions Except Flemington and Hinesville

1. A. General. The following signs are allowed in all districts without a sign permit:

Vending machines, ATMs and gasoline pump kiosk signs.

2. Temporary signs on construction sites.

3. Banners mounted on a pole, otherwise known as “quill flags”. However, only one (1) per business or tenant is allowed and such pole-mounted banners

must be located no closer than ten (10) feet from the right-of-way or other property line, shall not be larger than 24 sq. ft. in area and shall be placed on poles no more than eight (8) feet in height. They shall be maintained in good physical condition with no tattered edges or tears.

4. Any sign attached to a vehicle or trailer that is used in the normal day-to- day operation of the business advertised on the vehicle. The primary use of any vehicle or trailer which contains a sign must serve a useful function in the transportation or conveyance of persons or commodities from one place to another, including transportation to and from work. A vehicle or trailer primarily used for advertising shall not be considered a vehicle or trailer used in the conduct of business and is prohibited.

5. Signs that are attached to, painted on, or etched into a window or displayed within 12 inches (measured horizontally) of the window and are legible from outside of the window. Such signs shall not exceed 10% of the window area on each façade and, in combination with all other window, wall, projecting, canopy, or awning signs on the lot, shall not exceed the maximum permitted sign area for the building.

B. Lighting. Except for the signs in subsection A.1. above, no signs allowed without a permit listed above shall be illuminated.

Sec. 303-8 Signs Allowed in All Districts without a Sign Permit Applicable Only in Flemington and Hinesville

A. General. The following signs are allowed in all districts without a sign permit:

1. Vending machines, ATMs and gasoline pump kiosk signs.

2. Temporary signs not included in Sec. 303-6(K) [Standards by Sign Type - Temporary Signs].

3. Banners mounted on a pole, otherwise known as “quill flags”. However, only one (1) per business or tenant is allowed and such pole-mounted banners

must be located no closer than ten (10) feet from the right-of-way or other property line, shall not be larger than 24 sq. ft. in area and shall be placed on poles no more than eight (8) feet in height. They shall be maintained in good physical condition with no tattered edges or tears.

4. Any sign attached to a vehicle or trailer that is used in the normal day-to- day operation of the business advertised on the vehicle. The primary use of any vehicle or trailer which contains a sign must serve a useful function in the transportation or conveyance of persons or commodities from one place to another, including transportation to and from work. A vehicle or trailer primarily used for advertising shall not be considered a vehicle or trailer used in the conduct of business and is prohibited.

5. Signs that are attached to, painted on, or etched into a window or displayed within 12 inches (measured horizontally) of the window and are legible from outside of the window. Such signs shall not exceed 10% of the window area on each façade and, in combination with all other window, wall, projecting, canopy, or awning signs on the lot, shall not exceed the maximum permitted sign area for the building.

6. Identification plates for doors not exceeding 4 in. x 18 in. in size.

7. Alarm company signs and logos not exceeding 1 sq. ft.

8. Numbers identifying the street address of the building not exceeding 6 in. in height on residential properties or 12 in. in height on non-residential properties.

9. Directional signs meeting the requirements below.

a. Max. sign area - 4 sq. ft.

b. Max. sign height – 2 ft.

c. Max. sign lettering – 6 in.

d. No more than 2 directional signs per street entrance.

e. Signs shall not include any commercial logos, messages or insignia.

B. Lighting. Except for the signs in subsection A.1. above, no signs allowed without a permit listed above shall be illuminated.

Sec. 303-9 Additional Sign Requirements Additional requirements for signs are described in Table 303.9 below.

Table 303.9 Commercial/Industrial Zoning District Signs Wall Signs (also see Sec. 303-6.H) Zoning Districts:

C-1 OI DD Two wall, projecting, mansard or awning signs, of which the total area of signage cannot exceed ten percent of the building front of the business.

Zoning Districts:

C-2 C-3 LI I-1 Four wall, projecting, mansard or awning signs, of which the total area of signage cannot exceed fifteen percent of the building front.

PUD Zoning Districts (Only Applicable in Flemington and Hinesville) The size, height, and setback limitations for signs in a PUD shall be the same as the size, height, and setback limitations that apply to the most analogous use district.

Monument and Stanchion Signs (also see Sec. 303-6.D.1 and .2) Zoning Districts:

C-1 OI DD

● One (1) stanchion sign is allowed per parcel o Maximum height: 12 ft.

o Maximum sign area: 40 sq. ft. per business; not to exceed 100 sq. ft. of sign area for 3 or more businesses.

● One (1) monument sign is allowed per parcel o Maximum height: 5 ft.; incorporated columns 8 ft.

o Maximum sign area: same as stanchion signs Zoning Districts:

C-2 C-3

● One (1) stanchion sign or one (1) monument sign is allowed for one primary and one secondary street on which the property fronts. The parcel(s) must have a frontage of at least 100 feet on any secondary street or streets to qualify for an additional

stanchion or monument sign and it shall be half the size and height of the principal sign.

● Stanchion Sign:

o Maximum height: 20 ft., in Flemington 16 ft.

o Maximum sign area: 100 sq.ft. per business.

o Maximum sign area: two hundred 200 sq.ft. for 2 or more businesses

● Monument Sign:

o Maximum height: same as for stanchion signs o Maximum sign area: same as for stanchion signs Zoning Districts:

LI I-1

● One stanchion or monument sign is permitted per entrance for properties not part of an industrial park or not developed under a masterplan.

● Stanchion Sign:

o Maximum height: 20 ft.

o Maximum sign area: 200 sq. ft.

● Monument Sign:

o Maximum height: same as for stanchion sign o Maximum sign area: same as for stanchion sign

● In any master planned industrial development, the types and sizes of all signs shall be approved by the Planning Commission and the governing authority.

PUD Zoning Districts The size, height, and setback limitations for signs in a PUD shall be the same as the size, height, and setback limitations that apply to the most analogous use district.

IC District in Midway The size, height, and setback limitations for signs in an IC zone shall be the same as the size, height, and setback limitations that apply to the most analogous use district.

Billboards (also see Sec. 303-6.D.3) Undeveloped properties in:

C-3 LI IC I-1 I-1 in Flemington

● Along interstate and state highways only.

● Billboards are only allowed on undeveloped properties and in zoning districts as indicated to the left.

Temporary Signs (also see Sec. 303-6.K) Windblown and Banner Signs

● Permitted 30 days at a time, four (4) times during a 12-month period.

● Size of a banner shall not exceed 60 sq. ft.

Temporary Stanchion Signs

● One temporary stanchion sign per parcel

● Maximum height: 6 ft.

● Maximum signable height: 32 sq. ft.

● Duration: No more than 6 months in a year Common Development Entrance Signs (also see Sec. 303-6.G) Permanent Entrance Signs to Common Developments (subdivision, office park, apartments, townhouses, condos, etc.)

● No more than two stanchion or monument signs may be placed per entrance.

● Signs shall be incorporated into a permanent landscape feature such as a wall or masonry columns. Said structure shall be made out of durable materials, including, but not limited to: brick, stone, wrought iron, or composite materials, but in no case shall

a wood sign be permitted.

● Maximum height: 8 ft.

● Maximum sign area: 12 sq. ft.

These signs shall be located outside of the right-of-way within easements.

Temporary Entrance Signs to Common Developments and for Construction

● Construction Entrance Signs:

o Shall be limited to 3 signs per site o Maximum height: 6 ft.

o Maximum sign area: 32 sq. ft.

o To be removed when construction is complete.

● Temporary Common Development Entrance Signs:

o Shall be limited to the entrance(s) of development.

o Maximum height: 6 ft.

o Maximum sign area: 32 sq. ft.

o Shall be removed: when 80 % of the subdivision is built out or after two (2) years whichever occurs first.

Signs in Residential and Agricultural Districts All residential districts (individual parcels)

● Only temporary signs, one or more per parcel allowed

● Maximum height: 5 ft.

● Combined maximum sign area: 16 sq. ft.

● Non-illuminated

● Allowable duration: Not to exceed 6 months in one calendar year Institutional/civic and nonresidential uses (churches, day cares, cemeteries, schools, etc.)

in residential districts along arterial and collector streets

● One monument sign

● Maximum height: 8 ft.

● Maximum sign area: 50 sq. ft.

● Electronic changeable message and/or illuminated signs:

o only if at least 100 ft. from residences o shall not shine or cause glare into residences o shall not exceed 12-foot candles of incident light measured at a distance of 10 feet.

o Exception: In Hinesville, variable message signs are not permitted in the downtown area.

Institutional/civic and nonresidential uses (churches, day cares, cemeteries, schools, etc.) in residential districts along local streets

● One monument sign

● Maximum sign height: 6 ft.

● Maximum sign area: 36 sq. ft.

● Only externally illuminated

● Not to shine or cause glare into residential areas Zoning Districts:

A-1 AR-1

● One (1) sign per parcel

● Maximum height: 8 ft.

● Maximum sign area: 32 sq. ft.

● Non-illuminated Sec. 303-10 Design Standards for Signs in the OC-1 District (Applicable in Flemington only) The City of Flemington Mayor and Council shall review each sign application for height and sign area requirements and for aesthetics and compatibility with the architecture of the building especially in the OC-1 District for compliance with the following design standards, which shall apply to existing and new development:

A. Sign structures shall be architecturally designed and incorporate design details, materials, and colors of the associated buildings.

B. When a building contains several store fronts, signs for the individual businesses shall relate well to each other in terms of locations, height, proportion, color, and illumination. Individual tenant sign panels should be uniform or similar in size. Maintaining continuity will enhance the appearance of the buildings and the common areas.

C. Internally lit illuminated cabinet signs are discouraged. The use of signs with a projected light source (spotlight), individually illuminated letters, either internally illuminated or backlit solid letters (reverse channel) are preferred, as they are easier to integrate into the design of the building.

D. If institutional/civic/community uses are located in residentially zoned areas, only nonilluminated or externally illuminated signage shall be allowed.

Sec. 303-11 Nonconforming Signs

A. General. A nonconforming sign is any sign existing on the effective date of this Ordinance which does not conform to the standards of this article and which was legal at the time it was erected. Nonconforming signs shall be permitted provided that the signs are maintained as required by this article.

B. Replacement. A nonconforming sign shall not be replaced by a sign which does not comply with the requirements of this article, except that the substitution or interchange of poster panels, removable sign faces, or changeable copy on nonconforming signs shall be permitted.

C. Changes.

1. No changes in shape, size, location or design, nor any changes to its sign cabinet shall be permitted except to make a nonconforming sign comply with all requirements of this article. This notwithstanding, the following exceptions apply:

a. If proposed changes to a nonconforming sign meet the requirements of this article in regard to size of sign face and sign height, the required setback requirements may be waived if relocation of the sign would be impractical and/or hindering traffic flow.

b. Replacement of a poster panel or a sign cabinet to a digital panel on nonconforming signs shall be permitted only if the size of the sign face and sign height are in conformance with this article.

2. If changes are allowed to a non-conforming sign, such changes shall not impede sight distances at driveways and street intersections and, as applicable, evidence shall be presented that any potential increase in dead and live loads to the foundation and structural members of the sign is in conformance with applicable building codes to prevent structural failure.

D. Minor repairs and maintenance. Minor repairs and maintenance of nonconforming signs, such as repainting, electrical repairs, and neon tubing, shall be authorized. Signs may be restored to their original non-conforming condition if they are damaged by fire, act of God or other cause demonstrated by the owner of the sign by clear and convincing evidence to be outside the owner's control.

Sec. 303-12 Removal of Signs

A. The following circumstances shall warrant removal of a sign:

1. Traffic hazards. Any sign constituting a traffic hazard or a menace to the motoring public or pedestrians shall be removed.

2. General maintenance. Every sign, including those signs for which permits are required and those for which no permit or permit fees are required, shall be maintained in a safe, presentable and good structural condition at all times. The sign owner shall be responsible for repair or replacement of defective parts, painting, repainting, cleaning and other acts required for the maintenance of the sign. If the sign is not made to comply with adequate safety and maintenance standards, the building official shall require its removal in accordance with this section.

3. Dangerous or defective signs. No person shall maintain or permit to be maintained on any premises owned or controlled by that person any sign that is in a dangerous or defective condition. Any such sign shall be removed or repaired by the owner of the premises or owner of the sign. Upon failure of the owner to remove or repair a dangerous or defective sign, the building official shall require its removal in accordance with this section.

4. Unlawful signs. The Building official shall require the removal of any sign which does not comply with the provisions of this article.

B. The following are the procedures for removal of signs.

1. The Building official shall cause to be removed any sign that endangers the public safety, such as an abandoned, dangerous, or electrically or structurally defective sign, or a sign for which no permit has been issued or has been revoked, or which is otherwise in violation of this article.

2. Whenever the Building official intends to remove a sign, the reasons for removal shall be stated in writing in a notice of removal. The notice of removal shall describe the sign and specify the violations which require removal. The notice shall state that if the sign is not removed or the violation is not corrected within ten business days, the sign shall be removed in accordance with the provisions of this section.

3. The notice of removal shall be served upon the holder of the sign permit, the owner of the property on which the sign is located, the owner of the sign, and the occupant of the property.

4. The notice of removal may be personally served by in-hand delivery, or sent by certified or by first class mail to the address on the permit application, or to the last known address of the permittee, the owner of the sign, the owner of the property on which the sign is located, or the occupant of the property. If any person to whom notice of removal must be delivered cannot be located and mailings are returned undeliverable, the Building official may notify that person by posting and affixing the notice of removal on the sign itself.

5. Any time periods provided in this section shall be deemed to commence on the date received if hand-delivered, the postmark date of any mailing, or the date of posting and affixing the notice on the sign itself.

6. Any person having an interest in the sign or the property may appeal the notice of removal, provided such person files a written notice of appeal with the Building official within ten business days from the notice.

7. Appeals shall be conducted in the same manner as other sign appeals or other appeals to the governing authority whichever applies.

8. If the Building official’s final determination is to remove the sign, then he/she shall proceed to have the sign removed or corrected to bring such sign into compliance with this article or to remove any unsafe condition.

9. When it is determined by the Building official that the sign would cause imminent danger to the public safety and contact cannot be made with the sign owner or building or property owner, no written notice shall have to be served prior to removal. In such emergency situation, the Building official shall document the unsafe condition and may correct the danger, with all costs being charged to the sign owner or the property owner.

10. If it shall be necessary for the Building official to remove the sign pursuant to the provisions of this Section, and it should be practicable to sell or salvage any material derived in the removal, the Building official may sell or salvage any material derived in the removal. The Building Department may sell the same at public or private sale at the best price obtainable and keep an account of the proceeds thereof. Such proceeds, if any, shall be used to offset the cost of removal to be charged to the sign owner or property owner.

11. Any sign removed by the Building Department shall become the property of the governing authority and may be disposed of in any manner deemed appropriate by such governing authority. The cost of removal shall constitute a lien against the property on which the sign was located and shall be recoverable in the same manner as property taxes. The cost of removal shall include all incidental expenses incurred in connection with the sign removal.

Sec. 303-13 Sign Variance

A. Variances from the provisions of this article shall be limited to the following hardship situations:

1. Where compliance with the regulations of this article would constitute a physical impossibility based on existing trees, plants, natural features, signs, buildings or structures on the lot in question and the variance proposed would not create a safety hazard to vehicular traffic or pedestrians; or

2. Where visibility of a conforming sign from the proposed street and within 50 feet of the proposed sign would be substantially impaired by existing trees, plants, natural features, signs, buildings or structures on a different lot; and

a. Placement of the sign elsewhere on the lot would not remedy the visual obstruction;

b. Such visibility obstruction was not created by the owner of the subject property; and

c. The variance proposed would not create a safety hazard to vehicular traffic or pedestrians.

B. Variances shall be limited to the minimum relief necessary to overcome the hardship. No variances shall be granted to allow a greater number of signs than would be allowed if the hardship did not exist.

C. Relief from the application of this article by use of variances granted by the applicable jurisdiction shall be granted only upon a finding of hardship as previously defined. Hearing on such variances shall be noticed using the same time frames and notice requirements as for variances from zoning decisions.

Sec. 303-14 Citizens Sign Appeals Board (Applicable in Hinesville only)

A. Establishment of the Board. There is hereby established a commission which shall be called the “City of Hinesville Citizens Sign Appeals Board” hereinunder referred to as the “Board.”

B. Board members. The Board shall consist of six members appointed by the Mayor and City Council, with each such elected official responsible for the selection of one Board member.

The terms of office of Board members shall be for three-year staggered terms. The Board shall elect from its membership a chairperson and such other officers as may be desired.

Officers shall be elected on a calendar year basis but may be reelected for succeeding terms. All members of the Board shall serve without compensation but may be reimbursed for actual expenses incurred in connection with their official duties.

C. Vacancies. Any vacancy in membership of the Board shall be filled for the unexpired term by the elected official responsible for the initial selection of the departing Board member.

The Mayor and City Council shall have the authority to remove any member for cause, on written charges, after a public hearing.

D. Powers of the Board. The Citizens Sign Appeals Board shall be authorized to perform the duties below. The procedures of the Board are described in subsection F below.

1. To hear and make recommendations to the Mayor and City Council in all hardship and other common sense appeals.

2. To hear any and all challenges to the enforcement of any provision or requirement of the City's sign ordinance as set forth herein or later amended.

3. To hear any and all challenges to any decision, determination, or order made by the City's Director of Inspections in enforcing the provisions of this Article and any amendments thereto.

E. Powers of the Mayor and City Council. In exercising the above powers, the Mayor and City Council may reverse, affirm, or modify the Board's recommendations, and to that end, shall have the powers of the Director of Inspections from whom the appeal is taken and may issue the necessary permit.

F. Procedures of the Board.

1. Rules and regulations. The board shall establish rules and regulations for its own procedure not inconsistent with the procedures of this Code. The board shall meet on call of the chairman. The board shall meet within 30 days after notice of appeal has been received.

2. Decisions. The Citizens Appeals Board shall, in every case, reach a decision and make a recommendation to the Mayor and Council without unreasonable or unnecessary delay. Each board recommendation shall be in writing and shall include the reasons for the decision. A certified copy of the recommendation shall be promptly forwarded to the Mayor and Council.

Article 304 Telecommunication Facilities and Towers Article 304 Table of Contents Sec. 304-1 Purpose The purpose of this Article is to impose certain permitting requirements for the siting of all wireless, cellular, television and radio telecommunications towers and antennas; to encourage the location of towers in nonresidential areas; to minimize the total number of towers within the community necessary to provide adequate personal wireless services to residents for all of Liberty County and surrounding areas; to encourage the joint use of new and existing tower sites among service providers; to locate telecommunications towers and antennas in areas where adverse impacts on the community are minimized; to encourage the design and construction of towers and antennas to minimize adverse visual impacts; and to enhance the ability of the providers of telecommunications services to deliver such services to the community effectively and efficiently.

Sec. 304-2 Administrator The Administrator for this Article is the zoning and/or building official.

Sec. 304-3 Applicability

A. General applicability. The requirements, provisions and limitations of this article shall govern the location of all wireless telecommunication, cellular telecommunication, television, microwave, radio or similar transmission towers or antennas installed.

B. Governmental exemption. The provisions in this article shall not apply to the governing authority’s properties, facilities or structures. Private facilities and structures placed upon the government authority’s property shall be governed by a lease agreement or similar instrument between the governing authority and the provider.

C. Amateur radio and receive-only antennas. This article shall not govern any tower, or the installation of any antenna, that is thirty-five (35) feet or less in height and is owned and operated by a federally-licensed amateur radio station operator from the operator’s residence or is used exclusively as a receive only antenna; provided, however, only one (1) such tower or antenna per residence shall be excluded from this article.

D. Pre-existing towers and antennas. Any tower or antenna for which a permit has been properly issued prior to the year 2000 shall not be required to meet the provisions of this article, other than Secs. 304-8 [Federal Requirements] and 304-9 [Building Codes and Safety Standards].

Sec. 304-4 General Provisions

A. A tower and/or antenna is considered a principal use if located on any lot or parcel of land as the sole or primary structure, and is considered an accessory use if located on a lot or parcel shared with a different existing primary use or existing structure. An existing use or structure on the same lot or parcel shall not preclude the installation of an antenna or tower.

B. For purposes of determining whether the installation of a tower or antenna complies with zoning district requirements, including, but not limited to, setback, buffer and other requirements, the dimensions of the entire lot or parcel shall control, even though the antenna or tower may be located on a leased area within such lot or parcel.

C. Towers that are constructed, and antennas that are installed, in accordance with the provisions of this article shall not be deemed to constitute the expansion of a nonconforming use of structure.

D. All towers over 35 ft. in height shall be designed and certified by a professional engineer licensed in the State of Georgia as structurally sufficient. The tower owner shall provide an inspection report at the time of the original constructions, and upon the addition of any new antenna to the tower. The report shall be signed and sealed by a professional structural engineer licensed by the State of Georgia, and shall certify that the tower meets all building codes, and FCC and ANSI operating specifications.

E. No tower shall be located in DM Districts.

F. Upon the transfer of an ownership interest in any tower, alternative tower structure, or lot upon which such a structure has been erected, the tower permittee shall notify the administrator of the transaction in writing within thirty (30) days.

Sec. 304-5 Co-Location

A. Co-location on existing towers. All towers, except amateur radio towers, shall be designed to accommodate the co-location of cellular telecommunication antennas according to the following:

1. For towers up to one hundred fifty (150) feet in height, the structure and fenced compound shall be designed to accommodate at least three (3) providers or the maximum number of users as determined by the most current technology, whichever is greater.

2. For towers greater than one hundred fifty (150) feet in height, the structure and fenced compound shall be designed to accommodate at least four (4) providers or the maximum number of users as determined by the most current technology, whichever is greater.

B. Co-location preferred. No new tower, except amateur radio towers, shall be permitted unless the applicant demonstrates to the satisfaction of the administrator and/or governing authority (as the case may be) that no existing tower or existing alternative tower structure can accommodate the applicant's proposed antenna. All evidence submitted shall be signed and sealed by appropriate licensed professionals or qualified industry experts. Evidence submitted to demonstrate that no existing tower or structure can accommodate the proposed antenna shall consist of the following:

1. That no existing towers or suitable alternative tower structures are located within 5,280 feet from the proposed site which will allow for the effective operation of the proposed antenna (as informed by industry standards);

2. That existing towers or structures are not of sufficient height to allow for the effective operation of the proposed antenna (as informed by industry standards);

3. That existing towers or structures do not have sufficient structural strength to support the applicant's antenna and related equipment (as informed by industry standards);

4. That the applicant's proposed antenna would cause electromagnetic interference with the antenna(s) on the existing towers or structures, or the antenna on the existing towers or structures would cause interference with the applicant's proposed antenna, and such interference cannot be effectively remedied;

5. That the cost or contractual provisions required by the tower owner to share an existing tower or structure or to adapt an existing tower or structure for sharing substantially exceed the cost and requirements of new tower development and are otherwise entirely unreasonable;

6. That the applicant adequately demonstrates that there are other limiting factors that render existing towers and structures unsuitable, other than economic reasons.

C. Inventory of existing sites

1. To facilitate the co-location of antennas, each applicant seeking to locate a new tower, alternative tower structure or antenna, or modify any such existing structure, shall provide to the administrator an inventory of its existing towers or alternative tower structures. The inventory shall include all such structures that are within the jurisdiction of the governing authorities of Liberty County; within a municipality located, in whole or in part, within Liberty County; or, within one (1) mile of the border of Liberty County, and shall include specific information about the location (latitude and longitude coordinates), height, design, tower type and general suitability for antenna co-location of each tower, and other pertinent information as may be required by the administrator.

2. The administrator may make such information available to members of the public, to include, without limitation, other organizations seeking to locate towers or antennas within Liberty County, and in such form and manner as the administrator deems appropriate; provided, however that the administrator is not, by sharing such information, in any way representing or warranting that such sites are available or otherwise suitable.

Sec. 304-6 Design and Construction Requirements The guidelines set forth in this section shall govern the design and construction of all towers, and the installation of all antennas, governed by this Article.

A. Engineer certification. All towers over thirty-five (35) ft. in height shall be designed and certified by a professional engineer licensed in the State of Georgia as structurally sufficient.

The tower owner shall provide an inspection report at the time of the original constructions, and upon the addition of any new antenna to the tower. The report shall be signed and sealed by a professional structural engineer licensed by the State of Georgia, and shall certify that the tower meets all building codes, and FCC and ANSI operating specifications.

B. Appearance.

1. Towers and/or antennas shall either maintain a galvanized steel or concrete finish or, subject to any applicable standards of the FAA, be painted a neutral color to reduce visual obtrusiveness.

2. At all tower sites, the design of all buildings and related structures shall use materials, colors, textures, screening, and landscaping that will blend the tower facilities to the natural setting and building environment. Any equipment or cabinet that supports telecommunication facilities must be concealed from public view and made compatible with the architecture of the surrounding structures or placed underground. Equipment shelters or cabinets shall be concealed from public view by using landscaping and materials and colors consistent with the surrounding backdrop. The shelter or cabinet must be regularly maintained.

D. Equipment design on alternate towers. For antennas installed on a structure other than a tower, the antenna and supporting electrical and mechanical ground equipment shall be of a neutral color to make the antenna and related equipment visually unobtrusive.

E. Lighting. Towers shall not be artificially lighted, unless required by the FAA or other applicable authority. If lighting is required, the governing authority may review the available lighting alternatives and approve the design that would cause the least disturbance to the surrounding views. The lighting shall be dimmed or changed to red lights from the sunset to sunrise.

F. Signage. No signage or other identifying markings of a commercial nature shall be permitted upon any tower or alternative tower structure except one sign not more than three square feet identifying the owner of the tower and “No Trespassing” signs.

G. Historical sites and scenic views. To the extent practical, telecommunication facilities shall not be placed in a direct line of sight with historic or scenic view corridors as designated by the governing authority or by any state or federal law or agency.

H. Access. Access to the tower site shall be restricted to minimize visibility of the access.

Where possible, existing roads shall be used. Where no roads exist, access shall follow the existing contours of the land to minimize the visual impact of the site on the surrounding area.

I. Other. Such other additional requirements as the administrator and/or governing authority (as the case may be) shall reasonably require minimizing the visual impact of the site on the surrounding area.

J. Security. All towers and supporting equipment shall be enclosed by fencing not less than six (6) feet in height and shall also be equipped with appropriate anti-climbing devices.

Fencing shall be of chain link, wood or another approved alternative.

K. Landscaping. The following requirements shall govern landscaping surrounding all towers.

1. Where adequate vegetation is not present, tower facilities shall be landscaped with a landscaped strip of plant materials which effectively screens the view of the tower compound. Landscaped strips shall be a minimum of ten (10) feet in width and eight

(8) feet in height at planting and located outside the fenced perimeter of the compound.

2. Existing mature tree growth and natural landforms on the site shall be preserved to the maximum extent possible. Where natural vegetation around the perimeter of the site would provide an adequate visual screen, an undisturbed buffer may be utilized.

The applicant shall provide a site plan showing existing significant vegetation to be removed, and vegetation to be replanted to replace that lost.

3. Landscaping shall be maintained by the provider and shall be subject to periodic review by the administrator to assure proper maintenance. Failure to maintain landscaping shall be deemed a violation of this article.

L. Maintenance impact. Equipment at a transmission facility shall be automated to the greatest extent possible to reduce traffic and congestion. Where the site abuts or has access to a collector or local street, access for maintenance vehicles shall be exclusively by means of the collector or local street, utilizing existing access to the property on which such facility is to be located, where possible.

Sec. 304-7 Setbacks and Separations The following setbacks and separation requirements shall apply to all towers:

A. Towers shall be set back a minimum distance equal to the height of the tower from its base to any public right-of-way or occupied structure, or property line of the lot or parcel containing the tower.

B. Guy wires and accessory buildings and facilities shall meet the minimum accessory use location and setback requirements.

C. Towers shall not be located closer than five thousand two hundred eighty (5,280) feet from any existing tower; however, that requirement might be waived if the tower is required due to technological reasons or if it is visually superior.

Sec. 304-8 Federal Requirements

A. All towers must meet or exceed current standards and regulations of the FAA, the FCC, and any other agency of the federal government with the authority to regulate towers and antennas.

B. If such standards and regulations are changed, the permittee, owner or the lessee of the tower and/or antenna governed by this article shall bring such tower and/or antenna into compliance with such revised standards and regulations within six (6) months of the effective date of such standards and regulations, unless a more or less stringent compliance schedule is mandated by the controlling federal agency.

C. Failure to bring such tower and/or antenna into compliance with such revised standards and regulations shall be deemed to be a declaration of abandonment of the tower and/or antenna and constitute grounds for the removal of the tower or antenna at the owner's, permittee's, or lessee's expense. Any such removal by the governing authority shall be in the manner provided by the code governing unsafe and abandoned structures.

Sec. 304-9 Building Codes and Safety Standards

A. All towers over thirty-five (35) ft. in height shall be designed and certified by a professional engineer licensed in the State of Georgia as structurally sufficient. The tower owner shall provide an inspection report at the time of the original constructions, and upon the addition of any new antenna to the tower. The report shall be signed and sealed by a professional structural engineer licensed by the State of Georgia, and shall certify that the tower meets all building codes, and FCC and ANSI operating specifications.

B. To ensure the structural integrity of towers, the owner, permittee or subsequent lessee of a tower or alternative tower structure shall ensure that it is maintained in compliance with standards contained in applicable local building codes and the applicable standards for towers that are published by the Electronic Industries Association, as amended from time to time.

C. If, upon inspection, the administrator concludes that a tower fails to comply with all applicable codes and standards, or constitutes a danger to persons or property, then upon receipt of written notice by the owner, permittee or lessee of the tower, said party shall have fifteen (15) days to bring the tower into compliance with such standards.

D. Failure to bring such tower into compliance within fifteen (15) days shall be deemed a declaration of abandonment of the tower and constitute grounds for removal of the tower as provided in code sections, governing unsafe or abandoned structures. Prior to the removal of any tower, the administrator may consider detailed plans submitted by the owner, permittee or subsequent lessee for repair of substandard towers, and may grant a reasonable extension of the above referenced compliance period.

Sec. 304-10 New Tower Application Requirements Application for a permit for any telecommunications facility shall be made to the administrator by the person, company, organization, or duly authorized agent thereof, that will own and operate the telecommunications facility. An application will not be considered until it is complete. The administrator is authorized to develop application forms to assist in providing the required information and facilitate the application process. Except for a co-location information submittal, the following information shall be submitted when applying for any permit required by this article and must be submitted for an application to be considered complete:

A. Site plan or plans to scale specifying the location of telecommunications facility, transmission building and/or other accessory use, access, parking, fence, landscaped area, and adjacent land uses. Applicants shall submit both a paper location map and, if requested by the administrator, a digitized location map in a format compatible with the GIS software utilized by Liberty County, Georgia.

B. Landscaped plan to scale indicating size, spacing and type of plantings as required per this ordinance.

C. A full description of the environment surrounding the proposed telecommunications facility, including any adjacent residential structures and districts, structures and sites of historic significance, streetscapes, or scenic view corridors.

D. A description of anticipated maintenance needs for the telecommunications facility, including frequency of service, personnel needs, equipment needs, and traffic, noise or safety impacts of such maintenance.

E. Report from a professional qualified engineer licensed in the State of Georgia, or other appropriate qualified industry expert, documenting the following:

1. Tower or antenna type, height, and design;

2. Engineering, economic, and other pertinent factors governing selection of the proposed design;

3. Total anticipated capacity of the telecommunications facility, including numbers and types of antennas which can be accommodated;

4. Evidence of structural integrity of the tower or alternative tower structure;

5. Structural failure characteristics of the telecommunications facility and demonstration that site and setbacks are of adequate size to contain debris; and

6. Certification that the antenna(s) and related equipment or appurtenances comply with all current regulations of the FCC.

F. Identification of the geographic service area for the subject installation, including a map showing the site and the nearest or associated telecommunications facility sites within the network. Describe the distance between the telecommunications facility sites. Describe how this service area fits into and is necessary for the service network (i.e., whether such antenna or tower is needed for coverage or capacity).

G. If the proposed site is zoned residentially or PUD, applicants must describe why an alternate site zoned A-1, AR-1, C-2 or C-3, LI, or I-1 was not proposed by identifying:

1. What good faith efforts and measures were taken to secure such an alternate site;

2. Why such an alternate site was not technologically, legally or economically feasible and why such efforts were unsuccessful; and

3. How and why the proposed site is essential to meet service demands for the geographic service area.

H. The administrator will review with special care justifications that appeal only to undue expense and/or to undue difficulties in entering into a lease or similar agreement. The administrator shall carefully weigh such claims, and the evidence presented in favor of them, against a project's negative impacts at the proposed site.

I. The applicant must provide a utilities inventory showing the locations of all water, sewage, drainage and power line easements impacting the proposed tower site.

J. The applicant must provide any other information which may be requested by the administrator to fully evaluate and review the application and the potential impact of a proposed telecommunications facility.

Sec. 304-11 Tower Co-location Application Requirements Any person or entity co-locating an antenna or antennas which will add no more than ten (10) feet to the height of the tower and related equipment or appurtenances on or around a tower for which a permit has already been issued shall submit the following information only:

A. The name of the person or entity co-locating the antenna.

B. The name of the owner of the tower.

C. The tower's permit number.

D. The location of the tower.

E. The remaining structural capacity of the tower.

F. Certification that the antenna(s) and related equipment or appurtenances comply with all current regulations of the FCC.

G. Such other information as may reasonably be required by the administrator.

Sec. 304-12 Administrative Approval

A. Uses allowed without conditional use. The following uses may be approved by the administrator after conducting a review:

1. If it is adequately demonstrated that antenna co-location is not possible for a given geographic antenna placement area, construction of a new monopole or stealth tower (no guyed towers) up to a height of one hundred and fifty (150) feet, including the placement of additional buildings or other supporting equipment used in connection with said tower or antenna, may be permitted in the A-1, AR-1, C-2, C-3, LI and I-1 Districts provided that it is minimum of 500 ft. from the closest residential zoning district (R-20, R-12, R-8, MFR, ATR, MHP, SFMH) as measured from the tower structure to the property line.

Such tower and all structures shall meet the setback, screening and buffer requirements contained herein, together with such additional conditions which may be reasonably imposed by the administrator to minimize the adverse effects of such placement on surrounding properties.

2. For co-location on alternate tower structures, if the addition of said antenna adds no more than ten (10) feet to the height of the existing alternative tower structure:

a. Installation of an antenna on an existing alternative tower structure in any zoning district, and further including the placement of additional structures or other supporting equipment used in connection with said antenna, provided that if such installation is proposed on an existing alternative tower structure located in in residential zoning districts, the applicant shall be required to (i) place all additional structures or other supporting equipment within the existing tower compound, and (ii) meet such additional conditions which may be reasonably imposed by the administrator to minimize the adverse effects of such placement on surrounding properties; or

b. Installation of an antenna on an existing county owned alternative tower structure in any zoning district, provided a lease or similar agreement authorizing the antenna has been approved by the governing authority.

3. For co-location on existing telecommunication towers, if the addition of said antenna adds no more than ten (10) feet to the height of the existing tower:

a. Installation of an antenna on an existing tower of any height in any zoning district, and further including the placement of additional structures or other supporting equipment used in connection with said antenna, provided that if such installation is proposed on an existing tower located in residential zoning districts (R-1 through MH) the applicant shall be required to (1) place all additional structures or other supporting equipment within the existing tower compound, and (2) meet such additional conditions which may be reasonably imposed by the administrator to minimize the adverse effects of such placement on surrounding properties, or

b. Installation of an antenna on an existing tower located on property owned, leased or otherwise controlled by the county in any zoning district, and further including the placement of additional buildings or other supporting equipment used in connection with said antenna, provided a lease or similar agreement authorizing the tower has been approved by the governing authority.

B. Review of submittals

1. The administrator shall respond to each application within forty-five (45) days of its receipt by either approving, approving with conditions, or denying the application. One

(1) forty-five-day extension of this review period may be exercised by the administrator if such additional time is deemed necessary to adequately assess the request. If the administrator fails to respond to the applicant within a maximum of ninety (90) days, the application shall be deemed to be approved.

2. Any decision by the administrator that results in the denial of a request to place, construct, or modify a telecommunications facility shall be in writing and supported by substantial evidence.

C. Appeal of administrator’s decision. If a permit application for a tower as a permitted use (without a conditional use) is determined by the administrator to not meet all applicable criteria of this article, and the administrator disapproves the application, the applicant may appeal the determination of the administrator to the governing authority in accordance with the appeal procedures of this Ordinance. The governing authority shall dispense with the appeal by either:

1. A determination that the application is valid and meets all applicable criteria of this article, which shall result in the issuance of a permit as set forth herein.

2. A determination that the application does not satisfy all applicable criteria of this article for approval without processing a conditional use. Applications which do not satisfy all applicable criteria must, as a result, be processed through the conditional use permit process.

3. Review of the decision of the governing authority shall be made within thirty (30) days by writ of certiorari to the superior court of Liberty County.

Sec. 304-13 Conditional Use Review

A. General

1. If the proposed location, height, setback or other aspect of a proposed telecommunication facility cannot comply with the requirements for administrators’ approval established in Secs. 304-7 [Setbacks and Separations] and 304-12 [Administrative Approval], then a conditional use permit shall be required for the construction of a tower or the placement of an antenna in any zoning district.

2. In granting a conditional use permit, the governing authority may impose additional conditions to the extent that it concludes such conditions are necessary to minimize adverse effects from the proposed tower on adjoining or nearby properties.

B. Application

1. All applications for conditional use permits shall be submitted to the administrator who shall present the application to the Planning Commission and then forward the same to the governing authority for its consideration.

2. Each application shall contain as a part thereof detailed plans and specifications. An application for a conditional use permit shall not be accepted for processing without the information required in this article. An application fee shall be charged by the administrator in the amount stated in this article.

C. Conditional use. Adjoining property owners’ notifications and the public hearing shall be administered in conformance with the conditional use requirements of Division VI.

Conditional use considerations are listed under Sec. 304-14 below.

Sec. 304-14 Considerations for Conditional Use Permits

A. Considerations for conditional use permits. Any denial of a request to place, construct or modify a telecommunications facility shall be in writing and supported by substantial evidence contained in a written record. The following factors may be taken into consideration in acting upon a conditional use permit application under the provisions of this article:

1. The height and setbacks of the proposed tower, antenna, and equipment and structures;

2. The proximity of the tower, antenna, and equipment and structures to residential structures and residential district boundaries;

3. The nature of uses on adjacent and nearby properties;

4. The surrounding topography;

5. The surrounding tree coverage and foliage;

6. The design of the tower, antenna, and equipment and structures, with particular reference to design characteristics that have the effect of reducing or eliminating visual obtrusiveness;

7. The proposed ingress and egress;

8. The availability of suitable existing towers or other structures for antenna co-location;

9. The impact of the proposed tower, antenna, and equipment and structures upon scenic views and visual quality of the surrounding area;

10. The needs of the applicant as balanced against the detrimental effects on surrounding properties;

11. The impact of the proposed tower or antenna(s) on adjacent and nearby properties;

and such other considerations as may be implicated by the provisions of this article.

B. Requirements for issuance of conditional use permit. The conditional use permit may be issued by the governing authority only upon satisfaction of the following requirements:

1. A proper application filed in accordance with this ordinance;

2. The applicant complies with the special conditions imposed by the governing authority for the purpose of reducing the harmful effects of the use on surrounding uses and ensuring compatibility with surrounding uses;

3. The governing authority determines that the benefits and need for the proposed conditional use are greater than any possible depreciating effects or damages to neighboring or nearby properties; and

4. All fees and other expenses required have been paid in full.

Sec. 304-15 Resubmittal of a Conditional Use Permit An application for a conditional use permit which has been denied shall not be resubmitted for a period of six (6) months and then only if the applicant can document a substantial change in need for a tower or antenna at the same location.

Sec. 304-16 Removal of Abandoned Facilities

A. Notice of abandoned antenna and structures. The owner or lessee of a tower or antenna shall promptly notify the administrator of its intent to abandon, or the abandonment of, any tower or antenna.

B. Removal [measures] of abandoned antennas and towers. Any tower, antenna, or other equipment and structure in support thereof that is not operated for a continuous period exceeding twelve (12) months shall be considered abandoned, and the owner of such antenna or tower shall remove the structure within ninety (90) days of such abandonment.

If said tower or antenna is not removed within said ninety (90) days, the governing authority may, in the manner provided in the code section, governing unsafe and abandoned structures, take such action as may be deemed necessary to remove, or cause to be removed, such tower, antenna, or other equipment and structure in support thereof at the owner's expense. If there are two (2) or more users of a single tower, then this provision shall not become effective until all users cease utilizing the tower.

Article 305 Solar Energy Systems Article 305 Table of Contents Sec. 305-1 Purpose The purpose of this Article is to facilitate the siting, construction, installation, operation, maintenance, and decommissioning of solar energy systems (SES) in all of Liberty County in a manner that encourages local economic development and protects the health, safety, and welfare of the citizens of said county, and at the same time mitigates any adverse impacts to wildlife, agricultural lands, forests, and other natural landscapes.

Sec. 305-2 Applicability This Article applies to the siting, construction, installation, operation, maintenance, and decommissioning of any new SES (as defined below) within all of Liberty County.

Unless otherwise expressly stated herein, an SES shall still comply with all applicable federal, state, and local laws and regulations, including the requirements of the Unified Zoning Ordinance.

Sec. 305-3 Definitions The definitions below apply to the Article.

A. Permit - Any permit required by federal, state, or local law or regulation, including this article.

B. Solar energy system (SES) - A device or structural design feature that provides for the collection of solar energy for electricity generation, consumption, or transmission, or for thermal applications, and all components and other improvements supporting or forming a part thereof; provided that such term shall refer to (1) photovoltaic SES that convert solar energy directly into electricity through a semiconductor device, or (2) solar thermal systems that use collectors to convert the sun's rays into useful forms of energy for water heating, space heating, or space cooling. As used in this article, SES shall exclude concentrated solar systems that use mirrors to focus the energy from the sun to create thermal energy that can be used to produce electricity.

C. Building-integrated solar energy system - An SES where solar materials are used in place of traditional building components such that the SES is structurally an integral part of a house, building, or other structure, for example as a building facade, skylight, shingles, or canopy.

D. Rooftop solar energy system (“rooftop SES”)- An SES that is structurally mounted to the roof of a house, building, or other structure.

E. Ground-mounted solar energy system - An SES that is structurally mounted to the ground and does not qualify as a building-integrated SES. For purposes of this Article, the acreage of land occupied by a ground mounted solar energy system is calculated by drawing a perimeter around the outermost SES solar panels and auxiliary structures, not to include visual buffer, perimeter fencing, or shading buffer. Substations and transmission lines outside this perimeter shall not be included in the calculation.

F. Small scale ground-mounted solar energy system (“small scale SES”) - A groundmounted SES that occupies less than three (3) acres.

G. Intermediate scale ground-mounted solar energy system (“intermediate scale SES”) - A ground mounted SES that occupies between three (3) and fifteen (15) acres.

H. Large scale ground-mounted solar energy system (“large scale SES”) - A groundmounted SES that occupies more than fifteen (15) acres.

I. Visual buffer - Natural vegetation, plantings, earth berms, and/or decorative fencing as required in the applicable article about Tree Protection, Landscaping and Buffering. The visual buffer is not part of the SES and shall not be included when (1) calculating the acreage of land occupied by the SES, or (2) determining whether the SES adheres to applicable setback requirements.

J. Residential solar energy system (“residential ground mount SES”) – A ground-mounted SES not to exceed 600 square feet that is located on a residentially zoned property and exclusively services residential structures.

Sec. 305-4 Required Approvals

A. Building integrated SES - Permitted in all zoning residential, commercial, industrial and agricultural districts, subject to any applicable building permit. Such SES’s are considered an accessory use even if visible from a public right-of-way.

B. Rooftop SES - Permitted in all zoning residential, commercial, industrial and agricultural districts, subject to any applicable building permit. Such SES’s are considered an accessory use even if visible from a public right-of-way.

C. Ground-mounted SES (small, intermediate and large) – Requires conditional use approval in all residential, commercial, industrial and agricultural districts and is subject to any applicable building permit in accordance with Article 603 [Conditional Uses]. Additionally, site plan approval is also required in accordance with Div. IV [Site Plan Review].

D. Residential ground-mounted SES – Permitted in residentially zoned districts and subject to applicable building permit. Such SES’s are considered an accessory use and are to be permitted in the same manner as a rooftop installation. These can be approved administratively by the LCPC and the applicant must sign and submit the Decommissioning Affidavit.

Sec. 305-5 Easements for Adequate Exposure to Sunlight Consistent with O.C.G.A. § 44-9-20 et seq., a property owner may obtain a solar easement from another property owner for the purpose of ensuring the building-integrated SES adequate exposure to sunlight.

Sec. 305-6 Requirements for Rooftop SES

A. Safety

1. The SES shall have a clear perimeter between it and the roofline to ensure emergency access and egress on the roof and to provide smoke ventilation opportunities.

2. The SES shall not extend beyond the exterior perimeter of the building unless the SES is explicitly engineered to do so.

B. Height

1. The SES mounted on a flat roof shall be given an equivalent exemption to the underlying zoning district's height standards as roof-mounted mechanical devices or equipment.

2. The SES mounted on a sloped roof shall not vertically exceed the highest point of the roof to which it is attached.

Sec. 305-7 General Requirements for Ground-mounted SES The requirements below apply to all small, intermediate, and large scale ground mounted SES, in addition to the specific requirements in this Article that apply to each SES size.

A. Visual buffer. A visual buffer along any perimeter where the SES is within one hundred

(100) feet of residentially used property or public right-of-way or other public space.

a. For a Residential Ground Mount SES, the buffer shall consist of a minimum 15- foot preserved or planted vegetative buffer.

b. For any other Ground Mount SES (small, intermediate, or large), the buffer shall consist of an 8-foot privacy fence and a minimum 25-foot preserved or planted vegetative buffer.

B. Impervious surface. The SES shall comply with federal, state, and local stormwater management, erosion, and sediment control provisions and impervious surface coverage requirements. For purposes of compliance with such regulations, the SES shall be considered pervious if it maintains sheet flow and allows for water to infiltrate under and around the panels through a pervious surface and into the subsoil.

C. Lighting. To reduce light pollution, lighting shall:

1. be limited to the minimum reasonably necessary for its safe operation;

2. be directed downward where reasonably feasible;

3. incorporate full cut-off fixtures; and

4. reasonably utilize motion sensors.

D. Trees. The SES shall comply with the applicable requirements of Article 404 [Tree Protection, Landscaping and Buffering].

E. Maintenance. The SES shall be maintained in good working order and condition.

Maintenance shall include, but not be limited to, painting, structural and mechanical repairs, integrity of security measures and general maintenance of the grounds (mowing, etc.).

F. Abandonment. The SES shall be considered abandoned if it ceases to produce electricity on a continuous and regular basis for twelve (12) months or a shorter period not less than four (4) months if appropriate assurances are not given by the owner of the SES that said interruption in electricity production is temporary. The SES shall also be considered abandoned in the event that the decommissioning plan applicable to said SES is not strictly and fully observed and performed.

G. Decommissioning. When the SES has reached the end of its reasonable life or is abandoned, it shall be decommissioned in accordance with the decommissioning plan approved as part of the permit application (see Sec. 305-9D).

Sec. 305-8 Specific Requirements for Intermediate and Large Scale SES The specific requirements below shall apply to intermediate and large scale SES unless it is otherwise indicated to apply to one or the other.

A. Setbacks. The SES shall be located no closer than:

1. the lesser of (a) fifteen (15) feet from any property line or easement or (b) the setback standards for the underlying zoning district, if any;

2. the lesser of (a) twenty (20) feet from any public right-of-way or (b) the setback standards for the underlying zoning district, if any; and

3. 50 feet and 100 from any residential dwelling unit for intermediate and large scale SES, respectively.

B. Signage. Signage for the SES shall comply with Article 303 [Signs]. Additionally, the following shall apply:

1. The SES shall have the following warning signs

a. displaying the dangers associated with an intermediate scale SES,

b. identifying the owner or operator of the intermediate scale SES, and

c. providing a 24-hour emergency contact phone number.

2. The SES may have signs that contain educational information about the SES.

C. Electrical connections. If the intermediate scale SES is connected to the public grid, then reasonable efforts shall be made to place underground all utility connections from the SES, depending on appropriate soil conditions, shape, and topography of the property and any requirements of the utility provider.

Sec. 305-9 Plans and Permits

A. Permit application. An application for a conditional use approval shall be submitted containing the following:

1. The address of the SES property;

2. The applicant's name, address, telephone number, and email address;

3. The property owner's name, address, and contact information (e.g. telephone number or email address);

4. If known, the SES operator's name, address, telephone number, and email address;

5. If known, the installation company's name, address, telephone number, email address, and license number; and

6. Evidence of the applicant's control of the property, such as a deed, lease, or option agreement with the landowner.

B. Site plan. The applicant shall submit a site plan that contains the following:

1. A diagram of the property and directly adjacent properties showing the locations of all existing and proposed structures (including solar arrays, inverters, transformers, electrical substations, and buildings), property lines, rights-of-way, roads, required setbacks, required signage, and required visual buffers;

2. A topographical map from the U.S. Geological Survey, or equivalent, that depicts in detail any vegetative cover, watersheds, floodplains, or wetlands on the property;

3. A topographic drawing of the property that indicates how stormwater currently drains from the property, identifies the location of discharge points or areas, and identifies any conditions present on the property that may contribute to significant soil erosion;

4. A map or list from the Georgia Department of Natural Resources that identifies any habitat for state endangered, threatened, or candidate species as well as archaeologically and historically significant resources on or adjacent to the property (for example, using the Georgia Biodiversity Portal and Historic Preservation Division);

5. A map or list from the U.S. Department of Fish and Wildlife (FWS) that identifies any habitat for federally endangered, threatened, or candidate species on or adjacent to the property (for example, using the FWS IPaC tool).

C. Certifications. The applicant shall submit an affidavit that provides, to the best of the applicant's knowledge:

1. Construction and operation of the SES will comply with all applicable federal, state, and local laws and regulations, including the requirements of this Ordinance unless otherwise expressly stated in this Article;

2. Before operation, a fire safety and evacuation plan will be filed with the appropriate fire code and emergency management officials, and will be available in workplace for reference and review by employees working on the premises; and

3. General liability insurance will be maintained throughout the life of the SES project.

D. Decommissioning plan. The applicant shall submit for review and approval a decommissioning plan that, based on the best available information at the time of the application, contains the following:

1. The name, address, telephone number, and e-mail address of the person(s) or entity(ies) responsible for implementing the decommissioning plan;

2. A statement of conditions that require the decommissioning plan to be implemented (e.g. termination of lease, condition of potential public safety hazard, etc.);

3. A removal plan that (a) identifies all structures, components, and non-utility owned equipment that shall be removed (as well as a reliable, itemized estimate of the cost for such removal and disposal activities, together with estimates of the current salvage value of such items, and (b) includes a plan for recycling or otherwise reusing all materials to the extent reasonably practicable;

4. A restoration plan to return the property to its condition prior to the installation of the SES or to some other condition reasonably appropriate to the designated land use after the SES is removed; and

5. A schedule for completion of all removal and decommissioning activities.

6. Updates to all decommissioning plans shall be submitted to LCPC for administrative review and approval no less than once every seven (7) years or immediately prior to any material improvement, alteration, or other modification to the SES, whichever first occurs, to reflect current information (e.g. current description of SES, cost estimate for removal, cost estimate for disposal activities, etc.). Such updates shall also certify that the SES currently complies with the requirements of this article and all other applicable local, state, and federal laws.

E. Owner agreements. To the extent requested by the governing authority, the owner of the SES and owner of the real property whereupon the SES is located shall execute such agreement(s) as may be furnished by the governing authority specifically acknowledging the obligations imposed under this article, including, without limitation, the consequences of failing to perform the terms of an approved decommissioning plan and the lien which will result from any removal and restoration activities undertaken by the governing authority pursuant to an order issued under Sec. 305-10 provided that the failure to request or execute any such agreement(s) shall in no way act to waive the requirements of this article or impair the rights and remedies of the governing authority hereunder.

Sec. 305-10 Enforced Decommissioning Ground-Mounted SES

A. Abandonment. The owner of any ground-mounted SES which is deemed abandoned by applicable governing authority following a hearing as provided below shall remove all facilities, equipment, and other improvements constituting or supporting the SES and restore the affected site to its condition prior to the installation of the SES or to some other condition reasonably appropriate to the designated land use. All such removal and restoration activities shall be undertaken in accordance with applicable local, state, and federal laws within such time and upon such additional conditions as set forth in an order from the applicable governing authority issued pursuant to this section, notwithstanding any previously approved decommissioning plan.

B. Hearing

1. Prior to requiring the decommissioning of an abandoned ground-mounted SES, the governing authority (or its designated public officer) shall furnish the owner of the SES, as well as the record owner of the real property whereupon the SES is located, a complaint stating the conditions which warrant removal of the SES, and containing a notice that a hearing shall be held before a public officer designated by the county administrator to hear such matters.

2. The hearing will be held at a place within the county as designated in the complaint on a day and time certain which shall not be less than ten (10) days after the date of said complaint.

3. The owner of the SES and the owner of the real property whereupon the SES is located shall be given the right to file a response to the complaint with the public officer and to appear in person or otherwise to give testimony at the hearing at the place and time specified in the notice.

4. The public officer shall preside at the hearing, and shall be authorized to administer oaths or affirmations, examine witnesses, and receive evidence at the hearing. The rules of evidence prevailing in courts of law or equity shall not be controlling in the hearing.

5. The proceedings at the hearing shall be recorded or taken down or made by such other procedure as may be undertaken either in verbatim or summary form to be reasonably accurate.

C. Removal order. If, after the hearing indicated above, the public officer determines that removal and restoration activities are required, the public officer shall cause to be delivered to the owner of the SES and owner of the property whereupon the SES is located an order which shall:

1. state in writing the findings of fact in support of such determination;

2. specify the remedial action required;

3. establish a specific period of time, reasonably established in relationship to the remedial action, during which such action must be commenced and completed, including, if necessary, separate commencement dates as to separate work; and

4. advise that failure to comply with the order shall authorize the governing authority and its employees, agents, and contractors to enter the property and undertake such removal and restoration activities, the cost and expenses of which shall constitute a lien on the SES and real property upon which it is located as provided for below.

D. Performance by the applicable governing authority. Failure to comply with any order issued pursuant to this section shall authorize the governing authority to undertake the removal and restoration activities prescribed in said order. In this connection, the governing authority shall be authorized to remove and dispose of the SES in such manner and on such terms as it determines appropriate. In no event shall the governing authority be obligated to salvage, store, sell, or preserve the SES, but may destroy or otherwise dispose of the same as it determines appropriate, without liability of any kind.

E. Lien

1. The cost of removal and restoration activities undertaken by the governing authority or its designee, and all actions and proceedings incidental thereto or authorized hereunder (including, without limitation, the fees and costs of legal counsel and experts) shall be a lien for such amount against the SES and the real property upon which it is located, and enforced and collected in the same manner as ad valorem property taxes.

2. The lien shall attach to the SES and related real property immediately upon the issuance of any order authorized under this section provided that, following the payment of all costs of associated with any remedial and related action authorized by the governing authority or its designated public officials with respect to said SES, the governing authority shall cause to be filed an itemized statement of the total sum of said costs in the office of the county clerk on a lien docket maintained by the said clerk for such purposes. The failure to file such itemized statement as provided above shall not invalidate or otherwise impair the effectiveness or priority of any related lien.

3. If any portion of the SES is sold for salvage which results in payment to the governing authority, the net proceeds of such sale shall be credited against the cost of the removal and restoration activities and all other enforcement cost incurred by the governing authority; provided that the governing authority shall be under no obligation to sell any portion of the SES and may dispose of the same as it deems appropriate.

Article 306 Manufactured Home and Recreational Vehicle Parks Sec. 306-1 Required Approvals Manufactured home (MH) and recreational vehicle (RV) parks shall require site plan review and approval pursuant to Division IV [Site Plan Review]. In addition to the site plan criteria in that division, MH and RV parks shall conform to the requirements of this Article.

Sec. 306-2 MH and RV Parks’ Design Standards

A. Co-location. MH parks and RV parks can co-exist on the same parcel of land. However, the two uses shall not be intermixed but, instead, shall be located in separate areas and meet the minimum parcel area requirements for each distinct use.

B. Permits. It shall be unlawful for any person to operate a MH or RV park unless the applicant holds a valid permit issued by the local health department pending an approval by the building official and LCPC and a business license if applicable, as well as all required local, state and federal licenses.

C. Signs. A MH or RV park identification sign shall not be located within the right-of-way.

D. Lot identification. All MH or RV lots shall be clearly marked with a number.

E. Lighting. All roads, walkways, and service areas shall be provided with lighting adequate to ensure the safety of pedestrian and vehicular traffic. All lighting shall be designed to reduce light pollution and minimize light leaving the site vertically as well as horizontally.

F. Garbage. There shall be at least one container for garbage collection per MH or RV lot.

Garbage cans shall be enclosed so that they are protected from animal intrusion.

G. Accesses to lots. No MH or RV lot within the park shall have direct access to a public street. Each lot shall have access to an approved internal roadway meeting the requirements of Sec. 306-5 [Roadways for MH and RV Parks].

H. Non-permitted uses. No part of any RV or MH park shall be used for the parking or storage of any heavy equipment or trucks being used for commercial distribution, towing, or other commercial-related activities.

Sec. 306-3 MH Park Design Standards

A. Minimum park area. The minimum area for a MH park shall be five net acres.

B. Lot area and density. All manufactured home lots shall have a minimum area of 3,600 SF where public (government owned) water and sewer is available and in areas where no public (government owned) water and sewer services are available, a minimum area of 8,000 SF shall be required even if a central system (privately owned) is available. However, the density shall not exceed eight manufactured homes per acre.

C. New park. A new park must have a minimum of 20 lots completed with all utilities and other required improvements, including roadways, before any lot may be occupied.

D. Recreation area. At least ten (10) percent of the MH park shall be set aside as a common recreation area. Recreation facilities shall be provided to meet the anticipated needs of the residents of the MH park. The recreation area shall be easily identifiable and accessible to the park residents.

E. Buffers and screening

1. A 20 ft. vegetative buffer setback consisting of evergreen shrubs at least 6 ft. in height around the perimeter of the park along the property lines or a privacy fence of the same height.

2. A MH park shall be screened along the public road frontage by a planting of evergreens at least six feet high and a privacy wall or fence of equal height.

F. Accessory uses. A park office, laundromat, maintenance buildings and recreation facilities are permitted in the MH park for the convenience of park occupants.

G. Setbacks

1. All manufactured homes and all buildings and structures within a MH park shall have a front setback of at least 35 feet from the right-of-way of any public street or highway;

a minimum setback of ten feet from the right-of-way of any street or drive within the MH park; a minimum setback of ten feet on each lot side; the manufactured home shall have a setback of ten feet to the rear lot line.

2. Manufactured homes shall be located at least 30 ft. from any common building.

3. For replacement units for existing MH parks, no manufactured home shall be located closer than ten feet to another manufactured home.

4. No accessory structure shall be erected within five (5) feet of any manufactured home or within ten (10) feet of any common building (i.e. offices or laundry facilities).

H. Off-street parking. Every manufactured home shall have two paved off-street parking spaces and a paved sidewalk to the front door.

I. Pets. No pets shall be sheltered in the crawlspace underneath a manufactured home.

J. Utility connections. Every manufactured home shall have its own water and sewer connection and other utility connections. All utilities shall be underground.

K. Stormwater. A MH park shall be so graded and drained so that stormwater will not stand in pools and puddles.

L. Access for haulers. Easy access for a manufactured home hauler shall be provided.

M. Tie-downs and skirting. All manufactured homes shall be secured to an approved foundation by tie-downs and be fitted with a foundation type or skirt around the entire base of the units. Such wall or skirt shall extend from the bottom (floor level) of the unit to the ground so that no open space remains between the unit and surface of the ground. Tiedowns, foundations, foundation walls and skirting shall comply with the applicable building codes and other related codes and ordinances.

N. Wind zone II. All manufactured homes shall be at a minimum rated as a wind zone II. This notwithstanding, pre-owned manufactured homes not rated as a wind zone II may be relocated after review by the zoning and building officials.

O. Gas tanks. There shall be no storage of liquid or gas fuels within MH parks except in storage areas authorized by the local fire department or the authorized representative.

P. Flood zone. If located in a flood hazard area, the following additional requirements apply for new parks:

1. All requirements of the Article 406 [Flood Damage Prevention] shall be met.

2. Lots must be elevated on compacted fill or on piers so that the lowest floor of the manufactured home will be at least one foot above the base flood elevation.

3. Notify each purchaser, renter or lessee that the manufactured home is located in a flood hazard area.

4. Prepare an evacuation plan to be used in case of flood and file it with disaster preparedness authorities. (See local emergency management plan.)

Sec. 306-4 RV Park Design Standards

A. Minimum park area. The minimum area for an RV park area shall be at least three acres.

B. Lot size and density. Each RV lot shall have the minimum dimensions of 30 feet by 70 feet. The maximum density of RV lot spaces shall be no more than eight lots per acre.

C. Registration office and staff. Each RV park shall have an office on the premises which shall be open during normal business hours Monday through Friday. Additionally, each RV park shall require at least one staff member to live on site in the event of weekend and evening arrivals and for emergencies.

D. Duration of stay

1. RVs do not meet HUD standards and are not designed for permanent living quarters.

As such, no RV shall remain in an RV park for a consecutive period of more than twelve months. Minimum re-entry time shall be 14 days.

2. The owner of an RV park shall keep a chronological RV lot guest register showing the arrival and departure dates of each vehicle. This register shall be open for the building official and LCPC to review and shall be made available on request.

E. Screening. An RV park shall be screened along the public road frontage and abutting other properties by a planting of evergreens at least six feet high or a six-foot high privacy fence.

F. Accessory buildings A park office, a small shop, laundromat, maintenance buildings, and storage buildings are permitted in an RV park for the convenience of park management and occupants.

Permitted accessory uses of a commercial nature and parking areas serving such accessory uses shall not exceed 2% of the land area of the RV park (exclusive of wetlands) nor more than 2,000 sq. ft., whichever is more, and shall be laid out and designed to serve the frequent trade or service needs of travelers patronizing the RV park.

No accessory building shall be permitted on an RV lot or attached to an RV.

G. Setbacks

1. There shall be a boundary setback of 20 feet around any RV park.

2. Service buildings, small retail buildings, service areas, and recreational areas shall be located at least 20 feet from any internal road, drive, or RV lot.

3. There shall be a minimum distance of ten feet between recreational vehicles.

H. Green space and recreational area. A minimum of 20 percent of the total usable area of an RV park shall be devoted to green space exclusive of wetlands and marshlands. At least one active recreation area which consists of a minimum of ten (10) percent of total usable acreage of the recreational vehicle park parcel (e.g. community centers, laundromats, swimming pools, playgrounds, and/or other recreational equipment or sites) shall be provided. The recreation area shall be easily identifiable and accessible to the park residents.

I. Parking pad. Each lot shall have a paved pad a minimum of 10 feet by 40 feet for the RV itself and a paved parking area for an automobile a minimum of 10 feet by 30 feet.

J. Additional parking. Adequate common area shall be set aside for parking of vehicles, boats, or other recreational equipment. This area shall be paved.

K. Utilities

1. RVs shall be provided with all utilities, including sewage, but not gas, unless gas is to be the method of heating. All utilities shall be underground. Electric utilities shall comply with current building codes. Water and sewer utilities shall meet all state and local requirements.

2. If public sewer services are available to all RV spaces, service stations shall not be required. If public sewer services are not available to all RV spaces, then a sanitary station shall be provided according to Board of Health Rules and Regulations, and Georgia Environmental Health regulations.

L. Lighting. All roads, walkways, and service areas shall be provided with lighting adequate to ensure the safety of pedestrian and vehicular traffic. All lighting shall be designed to reduce light pollution and minimize light leaving the site vertically as well as horizontally.

M. Weather alert system. A public weather alert system like a siren shall be installed to forewarn RV park occupants about dangerous weather conditions.

N. Flood zone. Each RV located in a flood zone shall meet the minimum requirements of the applicable flood ordinance. RVs shall remain mobile and able to be moved from its location at any given time. Therefore, no structures or buildings shall be attached to an RV.

O. Maintenance. RV parks shall be maintained in good condition and not permitted to create any public nuisances. The recreational vehicles shall also be maintained so as not to create a visual nuisance and to ensure they remain roadworthy in the event that they are required to be evacuated at a moment's notice due to dangerous weather conditions. The RV park owner shall create additional covenants or park rules to regulate the day-to-day operations (noise, pets, etc.).

Sec. 306-5 Roadways for MH and RV Parks

A. The entrance road into the park shall have a pavement width of 30 ft. with an adequate curb radius.

B. All roadways within the park shall have a minimum right-of-way of 30 feet, exclusive of parking, and shall have a minimum paved width of 22 feet.

C. No access roadway the park shall be located closer than 150 feet to any public street intersection.

D. The number of entrances and/or exits shall not exceed the ratio of one per 150 feet of park frontage. Parks with less than 150 feet frontage are only allowed one combination ingress and egress road.

E. Roadway intersections within the park shall be at least 150 feet apart and no greater than 1,000 feet apart.

F. All roadway intersections shall be provided with a full cut-off streetlight. New parks shall be provided with adequate security lights within the park and at each entrance of the park.

G. All dead-end roadways shall terminate in a cul-de-sac with a minimum turning radius of 80 feet, exclusive of parking. In lieu of a cul-de-sac, other methods to achieve vehicular turnaround may be approved by the building official or LCPC.

Division IV Site Plan Review Article 401 Site Plan Review Article 401 Table of Contents Sec. 401-1 Purpose The purpose of this Article is to promote orderly development of the County and the cities within it that complies with the provisions of this Ordinance.

Sec. 401-2 Terms Defined Some terms used in this Article apply only to this Article and are defined below.

A. New development – Development, as defined in Division VIII, of a parcel which currently has minimal to no improvements.

B. Major redevelopment - Redevelopment of land, as defined in Division VIII, from which most or all previous improvements have been or are proposed to be removed.

C. Existing development – A parcel that is currently developed and may or may not have an approved site plan.

D. Modification to existing development – Any change to an existing development which may include a change to a structure, change to the parking lot, change of use, redevelopment (not major), etc.

E. Major site plan review – Review of a site plan which requires compliance with all site plan criteria.

F. Minor site plan review – Review of a site plan which requires compliance with one or more, but not all, of the site plan criteria.

G. Plan reviewer – The applicable personnel designated herein to conduct site plan reviews (this is dependent on the location of the subject property).

H. Site layout - A drawing of existing and/or proposed improvements to a given lot, typically used to show minor changes which do not require licensed professionals to design.

Sec. 401-3 Applicability and Procedures

A. In general, site plan approval is required for all development except lots used for singlefamily dwellings and duplexes and as otherwise exempted below.

B. New development or major redevelopment shall require major site plan review.

C. Modifications to existing development shall require minor site plan review if such modifications affect any of the site plan criteria. Compliance with those criteria is required and, if there are elements of an existing site that are unsafe or are a hazard to the public, minor site plan review shall also require compliance with any criteria it is determined will correct or help mitigate the deficiency or hazard.

D. All reviews, determinations and decisions on site plans required in this Article are conducted and made by LCPC except for development in Liberty County, in which case they are conducted by staff of the County Building and Licensing Department. The applicable staff is referred to in this Division as the “plan reviewer.” This notwithstanding, Liberty County may delegate its plan review responsibilities to LCPC at any time.

E. Conditions may be imposed on any decision provided it is relevant to an applicable criterion and is needed for a project to meet that criterion.

F. Prior to issuance of a Certificate of Occupancy by the building official, the development shall be closed out as specified in this Article.

G. The above notwithstanding, modifications to existing development may only require a site layout if the plan reviewer determines a layout, rather than a site plan, will be sufficient to determine compliance with any applicable criteria where such criteria are not required to be prepared by a licensed professional such as an engineer, surveyor, architect, or landscape architect. Site layouts shall not have to comply with the application, site plan requirements and project close-out provisions herein. Site layouts shall be on one or more sheets no smaller than 8½” x 11” and, while they don’t have to be to scale or professionally drafted, they shall be proportional and neatly drawn.

Sec. 401-4 Complete Applications No minor or major site plan review will take place until an application has been deemed complete.

For an application to be complete, it shall contain the following, as a minimum:

A. Applicable fees.

B. General engineering review application and any other forms provided to the applicant.

C. One full-sized paper copy and one electronic copy in pdf format of the site plan which shows the information outlined below.

D. Other submittals required by the applicable review criteria (i.e. hydrology report, etc.).

Sec. 401-5 Site Plan Requirements Site plans shall conform to the requirements and contain the elements listed herein, as applicable.

Specific elements may be waived where it is determined by the plan reviewer that such information is not relevant to the application or the applicable criteria.

A. General requirements

1. Site plans shall be at a sufficient scale to permit the review of all elements of the plan and shall not exceed 2’ x 3’ in size unless requested and necessary for the review.

2. Each sheet of the plans shall have the following information:

a. title of development

b. address of the property

c. preparation date and any revision dates

d. north arrow

e. scale stated and shown graphically

f. name and address of owner of record and name of applicant if not the owner

g. name, seal (as applicable) and signature of all professionals engaged by the applicant in preparing the sheet or page such as planners, engineers, architects, surveyors, etc.

B. Required elements

1. Cover sheet with vicinity map.

2. Road names and the names of all owners of record of all abutting properties.

3. Location and dimensions, including square footage of footprints, of all existing and proposed structures.

4. Limits of disturbance.

5. Location and layout of provisions and facilities for vehicular, pedestrian and bicycle traffic.

6. Calculation of required parking, loading and stacking, as applicable.

7. Landscaping plan (see Article 404 [Tree Protection, Landscaping and Buffering]).

8. Calculation of size of impervious and pervious areas and greenspace, in square feet.

9. Grading plan.

10. Information regarding all proposed lighting, including fixture type, mounting location and height, illumination levels and distribution (see also Article 402 [Parking Lots] and subsection C below).

11. Location of outdoor use areas with indication of use if not evident.

12. Location of existing and proposed site features, including retaining walls, fences, etc.

13. Utility plan showing, as applicable, existing and/or proposed potable water, sewer, stormwater, reuse water and drainage systems.

14. Additional information as may be necessary to demonstrate compliance with the applicable site plan criteria.

C. Photometric lighting plan

1. If a photometric lighting plan is required pursuant to Article 402 [Parking Lots], it shall meet the requirements of this subsection.

2. The photometric lighting plan shall be drawn to a scale no larger than one inch equals 50 feet and shall contain the following information:

a. 2.0 foot-candle contours;

b. The type of lamp to be used in each fixture, including lamp wattage, lumen output and diagram showing typical illumination pattern;

c. The type of fixtures, including a picture of the fixture;

d. Operational information (i.e. off or dimmed during non-business hours, motionsensor, photo-sensor, etc.); and

e. The seal of a qualified Georgia-registered design professional.

Sec. 401-6 Review Criteria The plan reviewer shall approve a site plan, with or without conditions, if the proposed development meets all of the following criteria for major site plan review or all the applicable criteria for minor site plan review.

A. Compliance with ordinance and other Standards The proposed development shall comply with the applicable provisions in Divisions II and V, the applicable standards and specifications, if any, of the municipality and the applicable provisions in State of Georgia Rules and Regulations Chapter 120-3 “Rules of Fire Safety Commissioner” currently in effect and as may be amended in the future. For convenience, excerpts of the current requirements of Chapter 120-3 are included in Appendix I of this Ordinance.

B. Parking lots – See Article 402 [Parking Lots].

C. Pedestrian provisions – See Article 403 [Pedestrian Provisions].

D. Outdoor lighting In addition to the parking lot lighting required in Article 402 [Parking Lots], the following lighting requirements shall apply.

1. Outdoor lighting fixtures shall be recessed, shielded or fully-cut off fixtures.

2. Lighting shall be designed to minimize glare on adjacent properties and public streets.

Such design may include utilizing LED lighting with a color temperature of 3000K or lower, operating the lighting with motion-or photo-sensors, reducing lighting during non-business hours, etc.

E. Outdoor uses

1. Exposed areas used for accessory uses such as storage, service, HVAC and other equipment, solid waste bins, utility buildings, etc., shall be located so as to have a minimum adverse effect on adjacent properties, and shall be screened if reasonably necessary to ensure compatibility with surrounding properties.

2. The requirement above shall not apply to outdoor areas used as an integral part of the principal use (i.e. outdoor retail sales, event venues, etc.).

F. Landscaping In addition to the requirements of Article 404 [Tree Protection, Landscaping and Buffering], additional landscaping or screening shall be required if needed to shield residential properties from headlights and glare.

G. Wetlands – See Article 407 [Wetland Protection]

H. Flood damage prevention – See Article 406 [Flood Damage Prevention]

I. Groundwater – See Article 408 [Groundwater Protection]

J. Drainage – See Article 405 [Drainage Control]

K. Erosion, sediment and pollution control – See Article 409 [ES&PC] Sec. 401-7 Project Close-out Requirements

A. General Prior to issuance of the certificate of occupancy by the building official, the plan reviewer shall close-out the project if it meets all the requirements in this section.

B. Procedure As the project is nearing completion, the plan reviewer will provide a letter to the developer and their engineer outlining the requirements herein to close out the project, as applicable and as determined by the plan reviewer. The plan reviewer may require additional information than what is included in this section provided it is pertinent to determining compliance with this Ordinance.

C. Required submittals

1. A written certification by the engineer that they have inspected the development and finds all construction in substantial compliance with the approved plans and specifications and the standard specifications of the governing authority.

2. A signed and sealed set of record drawings as set forth in subsection F below.

3. A detention pond certification in a form provided by the plan reviewer.

4. A signed Stormwater Management Agreement and the associated Stormwater Facilities’ Maintenance Plan.

5. A signed and sealed as-built hydrology report indicating compliance with the requirements of Article 405 [Drainage Control].

6. A copy of the Notice of Termination.

7. A landscape establishment bond pursuant to Article 404 [Tree Protection, Landscaping and Buffering]. The plan reviewer shall provide documentation as to the amount required and the form of the bond.

8. Dedication plat and deed for any lands being dedicated to the municipality.

D. Site considerations

1. All control measures for the final phase of the erosion, sedimentation and pollution control plan shall be in place and stabilized.

2. All temporary control measures shall be removed.

E. Final inspection and compliance with the approved site plan

1. Upon receipt of the record drawings, the plan reviewer shall coordinate with the building official and other municipal officials to schedule a final site inspection.

2. The plan reviewer shall inspect the site for substantial compliance with the approved site plan. Such compliance is required to close out the project.

F. Record drawings

1. Drawing requirements

a. In general, record drawing shall be a marked-up or annotated copy of the site plan.

b. The record drawing shall show as-built information for the following, as a minimum:

i. Location of all buildings and other above-grade improvements (i.e.

dumpsters, parking, sidewalks, etc.)

ii. Location of underground utilities (water, stormwater, sewer, irrigation, grease traps, etc.) and coordinates for the appurtenances (i.e. hydrants, valves, catch basins, cleanouts, meters, etc.).

iii. Inverts and other elevations for which a design invert or elevation was specified on the site plan, including but not limited to manholes, culverts, flumes, overflow control structures. The design invert or elevation shall be crossed out and the as-built invert elevation shall be indicated.

iv. Final contours of drainage facilities.

v. Easements, including the purpose and to whom they are dedicated.

c. Coordinates shall be used to locate buildings and at- or above-grade features.

2. Review and acceptance procedures

a. The initial submittal of the record drawings shall include one paper copy and one pdf copy.

b. The plans may be forwarded to, and comments solicited from, appropriate municipal officials such as the manager, mayor or administrator, building official, municipal engineer, emergency services personnel and utility department personnel.

c. Record drawings shall be reviewed by the plan reviewer who shall accept them upon a determination that the drawings are complete. Once accepted, one paper copy and one pdf copy shall be submitted to the plan reviewer. Additionally, a dwg file may be required in some jurisdictions.

d. By accepting the record drawings and supporting documentation, the plan reviewer is concurring that the drawings are complete and contain the information required by this Ordinance. The plan reviewer does not assume responsibility for the accuracy of the documents, as that remains with the professional engineer who signed and/or sealed the documents.

Article 402 Parking Lots Article 402 Table of Contents

A. Use of Parking Lots

B. Location

C. Surfaces and Pavement Markings

D. Accesses

E. Internal Driveways

F. On-site Traffic Circulation

G. Lighting

H. Vehicle Overhang

I. Fire Lanes

J. Modifications

K. Maintenance Table 402.1 Required Parking Spaces Table 402.2 Required Accessible Parking Spaces Table 402.3 Required Stacking Spaces Sec. 402-1 Purpose and Applicability

A. The purpose of this Article is to reduce hazards to public safety and ensure efficient traffic flow by establishing standards for vehicle parking and stacking and for loading areas.

B. For every building hereafter erected, extended or changed in use, and for every lot hereafter developed, there shall be provided off-street parking, stacking and loading as set forth in this Article.

C. References herein to “parking” and “loading” shall mean “off-street parking” and “off-street loading,” respectively, unless specifically stated otherwise. References to “parking lots” shall mean all accommodations for vehicles including parking spaces, loading spaces, internal driveways and vehicle stacking.

Sec. 402-2 General Parking Lot Requirements

A. Use of parking lots Parking lots shall not be used for the solid waste facilities, storage or sale of merchandise, vehicles for sale, vehicle repair or vehicle storage except for company vehicles. Non‐ required spaces or areas within a parking lot that will be used for such things shall be designated on the site plan.

B. Location Parking shall be provided on the same parcel as the principal building it is serving. An offsite parking lot may be allowed provided it complies with the following:

1. it provides for no more than 30% of the required parking or is used exclusively for valet or attended parking;

2. it is no more than 300 feet from the main parking lot as measured along the nearest ADA-compliant path of travel;

3. it is under the same ownership as the principal use and a restrictive deeded covenant running with the land to be used for off-street parking purposes states that such land shall not be encroached upon, used, sold, leased, or conveyed for any other purpose until such time as the principal building ceases to be required to provide such off-street parking facilities. Such deed shall be duly recorded.

C. Surfaces and pavement markings

1. Unless otherwise allowed or required herein, all parking lots shall be asphalt, concrete, permeable pavers or some other durable hard, all-weather material.

2. Parking lots shall be striped or marked with paint for the following, as applicable:

a. parking spaces and any designations (e.g. accessible, compact, etc.)

b. accessible aisles

c. stacking lanes

d. fire lanes and other no parking areas

e. crosswalks

f. arrows or other means to direct on-site traffic circulation

D. Accesses

1. Each parking lot shall have access for ingress and egress to a public street right-ofway. The number of accesses shall comply with State of Georgia Rules and Regulations Chapter 120-3 “Rules of Fire Safety Commissioner” currently in effect and as may be amended in the future (see Appendix I).

2. Access shall be a minimum of 12 feet wide for one-way traffic and 24 feet wide for twoway traffic but not wider than 40 feet exclusive of any turning radii. Modifications to these widths may be allowed if it is demonstrated that such modifications are needed due to site constraints and not the project as designed and are not to the detriment of the public and overall safety of the project.

3. In no case shall there be unrestricted access along the length of a collector or arterial street and, where necessary, landscaping, curbing or other effective barriers shall be provided along lot boundaries to control access of vehicles in areas not designated as an access.

4. Accesses to state highways shall comply with GDOT standards and demonstration of such compliance (i.e. permit or other official correspondence) may be required.

E. Internal driveways

1. There shall be provided adequate interior driveways to connect each parking and loading space with a public right-of-way.

2. Internal driveways shall be at least 24 feet wide where used with 90° angled parking;

16 feet wide for 60° angled parking; 14 feet wide for 45° angled parking and at least 12 feet wide for parallel parking or where there isn’t any adjacent parking. This notwithstanding, a driveway for two-way traffic shall be a minimum of 24 feet wide.

3. No parking or vehicle stacking shall be allowed in the internal driveways.

F. On-site traffic circulation

1. In general, the parking lot shall incorporate an integrated, functional and safe on-site circulation system for vehicles and pedestrians that minimizes vehicular-pedestrian conflicts, allows for safe vehicle stacking at signalized accesses and drive-thru lanes, and minimizes vehicle maneuvering within high-traffic lanes (i.e. near accesses and drive-throughs).

2. Vehicle lanes, pedestrian crossings and sidewalks connecting buildings and parking lots shall be provided as needed to ensure vehicular and pedestrian safety and convenience.

3. Signs or other markers shall promote vehicular and pedestrian safety.

4. Parking lots with dead-ended aisles are not allowed unless an adequate area for vehicles to turn around is provided at the end of the aisle so vehicles do not have to back up if no space is available.

G. Lighting

1. All areas of the parking lot shall have a minimum illumination level of 2.0-foot candles in all locations. This notwithstanding, levels as low as 0.5-foot candles may be allowed in low activity areas with minimal to no pedestrian traffic.

2. All parking lots accessible by the public shall be illuminated during night business hours of the applicable business.

3. Pole-mounted lights shall not exceed 20 feet in height unless it is demonstrated that a taller pole is needed for reasons such as safety or vehicle clearance.

4. Lighting fixtures shall be shielded or fully-cut off to reduce glare onto adjacent properties and streets and to reduce light pollution into the night sky.

5. A photometric lighting plan shall be required if the proposed use will be open during hours of darkness and the parking lot contains more than 20 parking spaces. If a photometric lighting plan is required, nationally recognized lighting recommendations for illuminance levels and uniformity ratios shall be followed, such as contained in the most current Illuminating Engineering Society of North America (IESNA) Lighting Handbook.

H. Vehicle overhang Parking spaces shall be designed so that vehicle overhang from parked cars and vans does not obstruct the clear width of adjacent accessible routes and sidewalks nor negatively impact any landscape plantings. If such design (i.e. wheel stops) effectively shortens the parking space, a longer overall length may be required to maintain a minimum usable depth of 18 feet for the space.

I. Fire Lanes Fire lanes shall be provided in compliance with the State of Georgia Rules and Regulations Chapter 120-3 “Rules of Fire Safety Commissioner” currently in effect and as may be amended in the future (see Appendix I).

J. Modifications

1. Any modifications to an existing parking lot that impacts the number or configuration of parking, stacking or loading spaces or changes the on-site traffic circulation shall conform with the requirements of this Article.

2. Any area designated for required parking, loading or stacking shall not be changed to another use or otherwise altered until other parking facilities in conformance with this Article are established elsewhere to serve the site.

K. Maintenance All parking and loading areas shall be maintained free of trash and debris. Surface, striping, curbing, lighting and signage shall be maintained in good condition. Additionally, landscaped and grassed areas around and within parking and loading areas shall be free of weeds, high grass and unpruned shrubbery and any dead plantings are to be removed and replaced.

Sec. 402-3 Parking Spaces

A. Number of parking spaces required

1. The number of vehicle parking spaces required shall be as specified in Table 402.1 (at end of Article) and the number of accessible parking spaces required shall be as specified in Table 402.2.

2. In calculating the requirements in Table 402.1, the following shall apply:

a. Fractional spaces - If requirements result in the calculation of a fractional parking space, the number of required spaces shall be rounded up to the nearest whole number (i.e. 5.1 = 6).

b. Seats – If the number of required spaces is based on seats, it shall include any outdoor seating.

c. Employees - If the number of required spaces is based on people (i.e. doctors, staff, employees, etc.), it shall be the maximum number of such people on site at any one time.

d. Occupancy – If the number of required spaces is based on occupancy, it shall be the maximum occupancy allowed by local and/or state authorities.

3. If more than one use listed applies (i.e. bowling alley and indoor recreation), the requirements for the more descriptive use shall apply (i.e. bowling alley).

4. For uses that are not listed in Table 402.1, the required parking shall be based on a comparable use or, if there are no comparable uses, the applicant shall provide documentation which demonstrates the number of spaces provided are adequate for the use.

5. A business which has two distinct uses (e.g. retail sales and restaurant), parking shall be provided for the use that requires the most spaces.

6. In the case of multiple uses occupying the same building (i.e. shopping/commercial plaza) or multiple buildings on the same lot, the total requirements for parking shall be the sum of the requirements for the various uses computed separately. This notwithstanding, shared parking shall be allowed and the required parking reduced up to 20% if a parking study or other documentation indicates the peak hours for the uses do not overlap and the proposed amount of parking is sufficient to accommodate the anticipated demands for each of the uses at peak hours.

7. In cases where it is demonstrated that the need for the number of spaces required is affected by the availability of public parking, public transit, etc., or services provided for residents (e.g. assisted living or elder housing), the required parking may be reduced up to 20%.

8. Accessory uses shall not be required to have additional parking spaces other than those required by the principal use.

B. Supplemental requirements In addition to the parking space requirements above, the following shall apply, as applicable.

1. Places of worship – Of the total required parking, 40% of the spaces may be in an unpaved area.

2. Elder housing – An area shall be designated for future expanded parking should the use change and/or more spaces are required.

3. Guest parking – Any required guest parking shall be specifically reserved, restricted and clearly designated as reserved for guest parking only.

4. Gas stations – If a gas station is associated with a retail store, 1 space shall be credited toward the number of required spaces for the associated retail store for every 2 pump dispensers.

5. Garages - If residential garage space is provided, 1 space shall be credited toward the number of required spaces for every 2 bays in the garage.

6. Shopping cart corrals – Spaces used for shopping cart corrals shall not count toward the number of required spaces. Site plans shall indicate how many corrals will be used within the parking lot.

C. Parking space dimensions

1. Standard - Except as otherwise allowed herein, each parking space shall be not less than 9 feet wide, nor less than 20 feet deep, exclusive of interior driveways.

2. Compact - The above notwithstanding, compact car parking spaces are allowed, subject to the following provisions:

a. Compact car parking spaces shall be not less than 8 feet wide, nor less than 16 feet deep, exclusive of interior driveways.

b. Compact car parking spaces may only be used for a use requiring 25 or more parking spaces as determined in this Article.

c. Up to 10 percent of the parking spaces may be designed for compact cars.

d. Compact car parking spaces shall be located to be as convenient as standard parking spaces and shall be grouped or placed in clusters of three or more rather than being scattered simply to solve parking layout difficulties.

e. Compact car parking spaces shall be clearly marked with the words "Compact Car Only” and/or identified with appropriate signage in compliance with the Manual on Uniform Traffic Control Devices (MUTCD).

3. Accessible - All provisions for accessibility within parking lots are included in Sec. 402- 4 and Table 402.2.

D. Changes to a structure or use

1. Should a structure be physically altered or enlarged in such a manner that it increases a parameter upon which the require parking is based (i.e. floor space, number of units, etc.), then the number of parking spaces available must be increased according to Table 402.1. This notwithstanding, additional spaces shall not be required if a parking study indicates the existing number of spaces is adequate for the change in the structure. Such study shall include, at a minimum, the number of available spaces in the existing parking area at various time of day and week with data collected over a period of at least a month.

2. Should the use of a structure be changed, the number of parking spaces shall be increased if the new use requires more than 10% additional spaces over what is currently available.

3. Prior to any change to a structure or its use, written notification describing the changes and, as applicable, a site layout of the changes shall be provided so a determination can be made by the plan reviewer as to whether additional parking spaces are required.

Sec. 402-4 Accessible Parking Requirements

A. Applicability All parking lots shall comply with the ADA Standards for Accessible Design, as currently in effect and as may be amended in the future, and the provisions herein. If there are any discrepancies between these provisions and the ADA Standards, the ADA Standards shall govern.

B. Number of spaces The number of accessible parking spaces provided shall be as specified in Table 402.2. If only one accessible parking space is provided, it shall be van-accessible. For every six or fraction of six accessible spaces that must be provided, one shall be a van-accessible space.

C. Access aisles

1. Each accessible parking space shall have an adjacent access aisle. The aisle shall:

a. be a minimum of 5 feet in width;

b. extend the full length of the parking spaces they serve;

c. be marked so as to discourage parking in them; and

d. adjoin an accessible route.

2. Two parking spaces are permitted to share a common access aisle.

3. Access aisles may be on either side of the parking space except for van-accessible spaces which shall have the aisle located on the passenger side of the space.

D. Size

1. All accessible spaces shall be a minimum of 20 feet long.

2. Regular accessible spaces shall be a minimum of 9 feet wide.

3. Van-accessible spaces shall be a minimum of 11 feet wide. This notwithstanding, if it is adjacent to an 8-foot wide access aisle, a van-accessible space may be a minimum of 9 feet wide.

E. Location Accessible parking spaces shall be located on the shortest possible accessible route from parking to an entrance. Where parking serves more than one accessible entrance, accessible parking spaces shall be dispersed and located on the shortest accessible route to the accessible entrance.

F. Identification

1. Each accessible parking space shall be designated by markings on the pavement and signage with the international symbol for accessible parking.

2. Signs shall meet MUTCD guidelines and be at least 12 inches in width and 18 inches in length and installed a minimum of 7 feet above the finished grade as measured to the bottom of the sign.

3. Signs for van-accessible spaces shall contain the designation “van accessible” either on the sign itself or as a sign appendage.

Sec. 402-5 Vehicle Stacking All development that includes a drive-through lane or requires vehicle stacking (i.e. car washes or oil change establishments where customers typically remain in the vehicle) shall comply with the provision of this section.

A. All stacking spaces shall be provided off-street.

B. Stacking spaces shall be a minimum of 8 feet wide and 20 feet long.

C. Number of Required Stacking Spaces

1. The number of stacking spaces required shall be as specified in Table 402.3 (at end of Article).

2. For uses that are not listed in Table 402.3, the required stacking shall be based on a comparable use or, if there are no comparable uses, the applicant shall provide documentation which demonstrates the number of stacking spaces provided are adequate for the use.

3. The required stacking space number includes the space at the point of service. In the case of a drive-through that has both an ordering station and a service window, the point of service shall be the ordering station.

4. The number of required stacking spaces may be reduced one-for-one if drive-through pull-out spaces are provided.

D. Each entrance to a drive-through lane and direction of traffic flow shall be clearly designated by signs and pavement markings. Raised medians may be required if deemed necessary to ensure compliance with the provisions of this Section.

E. Each drive-through lane shall be separated from the circulation routes necessary for access to the property and parking spaces.

F. Stacking spaces shall not impede on‐ or off‐site traffic and pedestrian movements nor block parking spaces.

Sec. 402-6 Loading Areas

A. Applicability and general provisions

1. Every use which requires the receipt or distribution by vehicles of material or merchandise shall provide loading areas which are sufficient for their requirements and conform to the provisions of this Section. A loading area shall include loading space(s) and may also include internal driveways and maneuvering areas.

2. Loading spaces shall not be used to satisfy parking or stacking space requirements.

3. Loading areas shall be clear and free of obstruction at all times.

B. Access Loading spaces shall be provided with a means of unobstructed ingress and egress to an alley or public street wide enough to accommodate expected vehicles. Where such ingress and egress are made to a public street, it shall be through driveways which meet required standards.

C. Location

1. Required loading areas shall be located on the same lot or parcel of land as the structure they are intended to serve.

2. Loading spaces may be either inside or outside the building.

3. To the extent feasible, loading areas shall be located to minimize visibility from public rights-of-way.

D. Safety considerations

1. A sufficient maneuvering area shall be provided on-site that allows all vehicles utilizing a loading area to enter a public street in a forward manner and that does not require any turning movements within a public street.

2. Loading areas shall not hinder the movement of traffic or pedestrians.

3. Loading spaces shall be adequate so that no vehicle being loaded or unloaded in connection with normal operations shall stand in or project into a public street, walk, alley or way.

4. Permanent wheel stops or curbing shall be provided where needed to prevent any vehicle using the loading area from encroaching on any required buffer, adjacent property, parking space, public street, sidewalk or internal driveway.

E. Surface All loading areas shall be paved with a hard-surface, all‐weather pavement of concrete or asphalt designed to carry the heaviest vehicle loads that can commonly be expected, including fire and sanitation equipment as well as delivery vehicles.

F. Lighting Loading areas shall be adequately lit. Lighting shall be minimized during periods when the loading area is not in use during non-business hours or when it faces a residential district or a structure with first-floor residential uses.

G. Setback from residential uses A minimum setback of 50 feet shall be required where loading spaces face a residential district or a structure with first‐floor residential uses unless the loading area is completely screened from view.

H. Size Each loading space shall be sized to accommodate the expected vehicles but shall be, at a minimum, 10 feet wide, 25 feet long and 14 feet high.

I. Number of required loading spaces

1. The uses below shall require, at a minimum, 1 loading space. Additional loading spaces may be needed to meet the requirements of the use

a. Retail stores with a minimum of 3,000 SF to a maximum of 25,000 SF in total floor area

b. Schools with 15,000 SF or more of gross floor area

c. Hospitals (in addition to any ambulance space)

d. Non-residential uses (other than retail) with 10,000 SF or more of gross floor area

2. Multifamily residences with less than ten dwelling units shall not be required to provide a loading space. Multifamily residences with between 10 to 30 dwelling units shall be required to provide 1 loading space. Multifamily residences with more than 30 dwelling units shall be required to provide 1 loading space for each 30 dwelling units or fraction thereof.

Table 402.1 – Required Parking Spaces Use Required Spaces Residential Single-family (att. or det.) and two-family dwellings 2 spaces per dwelling unit Multi-family dwellings 1½ spaces per dwelling unit and 1 guest space for every 4 units (see supplemental requirements in Sec. 402-3)

Elder housing and assisted living facilities ¾ space per dwelling unit (see supplemental requirements in Sec. 402-3) Manufactured home park 2 space per lot and 1 guest space for every 2 lots (see supplemental requirements in Sec. 402-3)

Places of lodging (e.g. hotels, motels, campgrounds, inn, etc.)

1 space per guest room or camper space, 1 space per employee and 1 guest space for every 10 guest rooms or camper spaces (see supplemental requirements in Sec. 402-3) Boardinghouses and bed and breakfasts 1 space per guest room and 2 spaces for residents of house Places of Assembly Places of worship, community halls, theaters, etc.

1 space for every 3 seats in main assembly area (see supplemental requirements in Sec. 402-3) Conference facilities/function halls 1 space for every 4 seats Funeral homes 1 space for every 3 people of maximum occupancy, 1 space for every employee and 1 space for every company vehicle Table 402.1 – Required Parking Spaces (cont’d) Use Required Spaces Medical Hospitals 1 space for every 2 hospital beds, 1 space per medical professional and 1 space for every 3 employees Health care services 10 spaces per doctor/medical professional or 2 for every dentist and dental hygienist, as applicable

Veterinary offices 2 for every veterinarian doctor and technician Skilled nursing facilities and group personal care homes 1 space for every 4 patient beds and 1 space for every 2 employees Offices, Restaurants and On-site Services (Non-retail) Fitness centers (e.g. gyms, dance and martial arts studios) 1 space for every 150 SF of floor area open to the public Personal service shops (e.g.

barbers, nail salons, hair salons) 3 spaces per station, chair, etc.

Services with minimal customer time on-site (e.g.

banks, dry cleaners, shoe repair, pet grooming, daycare, etc.)

1 space per employee, 1 space per business vehicle and 1 space for every 250 SF of gross floor area Offices, primarily serving clients off-site (e.g.

engineering, law firms, publishing, real estate, etc.)

1 space for every 200 SF of gross floor space and 1 space for every company vehicle Bars and nightclubs 1 space per 3 persons of maximum occupancy Restaurant 1 space for every 75 SF of gross floor space Fast food restaurant 1 space for every 75 SF of space open to the public and 1 space for every 3 seats

Laundromat 1 space for every 200 SF of gross floor space Retail Indoor retail, high-volume (e.g. convenience store, liquor store, drug store, etc.)

1 space per employee and 1 space for every 200 SF of floor area open to the public Indoor retail, general merchandise (e.g. hardware store, clothing store, gift shop, flower shop, etc.)

1 space for every 250 SF of floor area open to the public Table 402.1 – Required Parking Spaces (cont’d) Use Required Spaces Retail (cont’d) Indoor retail, large merchandise (e.g. furniture, mattresses, carpeting, appliances, etc.)

1 space for every 400 SF of floor area open to the public Indoor retail over 50,000 SF in gross floor space (e.g. big box store, shopping center, etc.)

1 spaces for every 250 SF of gross floor space Semi-outdoor retail (e.g.

building supplies, nursery/garden center, equipment rental, etc.)

1 space per employee and 1 space for every 300 SF of floor area open to the public (excludes bulk storage area, even if open to the public) Outdoor retail (e.g. auto dealership, boat sales, trailer sales, monuments, etc.)

1 space per 2,500 SF of outdoor display area open to the public Educational and Cultural Elementary and middle schools 1 space per employee, 1 space for every 17 classroom seats or 1 space for every 4 seats of maximum seating capacity in principal assembly area, whichever is greater Schools with driving-aged students 1 space for every 3 full- or part-time equivalent students, based upon maximum enrollment, and 1 space per employee Fraternities/sororities and dorms 1½ space for every 2 beds Cultural facilities (e.g. libraries, art galleries, museums, etc.)

1 space for every 400 SF of floor area open to the public Child care facilities 1 space for every employee, including teachers and administrators, and 1 space for every 3 children of

maximum occupancy Recreational Sporting clubs (e.g. country clubs, golf clubs, gun clubs, etc.)

1 space for every 5 members Indoor recreation with fixed seating 1 space for every 3 seats Indoor recreation without fixed seating 1 space for every 200 SF of gross floor area Outdoor recreation with spectator seating (i.e.

bleachers) 1 space for every 4 seats Table 402.1 – Required Parking Spaces (cont’d) Use Required Spaces Recreational (cont’d) Outdoor recreation without spectator seating 5 spaces per acre Bowling alleys 4 spaces per alley Industrial Auto services, customers generally drop-off vehicle 1 space per employee and 1 space for each 400 SF of floor area in garage Auto services, customers generally stay on-site 1 space per bay and 1 space per employee Industrial, warehousing and manufacturing without retail 2 spaces for every 3 employees, 1 space per company vehicle and 1 guest space per 10 employees Industrial, warehousing and manufacturing with retail sales or service 2 spaces for every 3 employees, 1 space per company vehicle and 1 space for every 150 SF of floor area open to the public for retail sales or service Table 402.2 – Required Accessible Parking Spaces Total Req’d Parking Spaces Required Accessible Spaces 1 to 25 1 (shall be a van-accessible space) 26 to 50 2 51 to 75 3 76 to 100 4 101 to 150 5 151 to 200 6 201 to 300 7 301 to 400 8 401 to 500 9 501 to 1,000 2 percent of total More than 1,000 20 plus 1 for each 100 over 1,000 Table 402.3 – Required Vehicle Stacking Spaces Use Req’d stacking spaces Oil change/auto repair (customers stay on premises), per bay 3 Carwash full-service, per bay 6 Carwash self-service, per bay 3 Non-food pick-up/drop-off, per lane 3 Food and beverages, per lane 9 Gas/fuel pump, per pump 2 School or daycare pick-up/drop-off 3 Article 403 Pedestrian Provisions Sec. 403-1 Applicability

A. Public sidewalks

1. To ensure current and future connectivity, for all new development and major redevelopment, sidewalks shall be constructed within the right-of-way of streets adjacent to the development. If site constraints render constructing the sidewalk within the right-of-way not feasible, the sidewalk shall be constructed within the required setback area and an easement shall be granted to the governing authority for the sidewalk that includes a 2-foot wide green strip between the sidewalk and the back of curb.

2. For modifications to existing development, construction of sidewalks described above shall not be required.

3. It shall be the developer’s responsibility to obtain all required permits and approvals from GDOT for sidewalks or other related work within state highway rights-of-way.

B. On-site sidewalks

1. For all new development and major redevelopment, an accessible route shall be provided from the adjacent public sidewalk, either existing or proposed, to the closest entrance that serves the primary function of the building. If a development is on a corner lot, to the extent feasible, an accessible route shall be provided from each street.

2. The provision above shall apply to modifications to existing development unless it is not feasible to install a sidewalk without impacting existing drainage facilities, required landscaping or tree quality points or required buffers.

C. Waivers The applicability requirements above may be waived or modified if:

1. there is no public sidewalk within 1,000 feet of the subject property;

2. there are no plans for a public sidewalk in the vicinity of the subject property; and

3. there will be no detrimental impact to the overall development pattern of the area nor to the general public if the sidewalk were not constructed.

Sec. 403-2 Design Standards Construction of sidewalks shall comply with the standards and specifications of the applicable jurisdiction. At a minimum, the standards below shall also apply. Should there be a conflict between these standards and other standards such as applicable design review standards or the jurisdictional specifications and standards noted above, the other standards shall apply.

A. Sidewalks shall be constructed of concrete.

B. Sidewalks shall be constructed a minimum of 5 feet wide.

C. Sidewalks shall meet ADA standards for accessibility.

D. Crosswalks shall be provided across all accesses. This shall not apply to driveways serving single-family residences or duplexes.

E. For off-site sidewalks, a green strip with a minimum width of 2 feet shall be installed between the sidewalk and the traveled portion of the adjacent street. If this is not possible or feasible and the sidewalk directly abuts the street, a high-back curb shall be installed along the street.

F. On-site sidewalks shall comply with the following:

1. Crosswalks shall be provided across internal driveways.

2. To the extent feasible, sidewalks shall cross internal driveways between curbed medians or islands.

3. Adequate sight distances at crosswalks shall be maintained and shall not be hindered by things such as landscaping, trees or buildings.

G. All crosswalks shall conform to the Manual of Uniform Traffic Control Devices.

Article 404 Tree Protection, Landscaping and Buffering Sec. 404-1 Applicability

A. All development shall comply with the applicable tree protection, landscaping and buffering standards referenced below as currently in effect and as may be amended in the future.

1. Liberty County – Code of Ordinances Chapter 8, Article VI – Land Clearing and Tree Protection

2. Flemington – Code of Ordinances Chapter 38, Article V – Landscape and Tree Protection

3. Hinesville – Code of Ordinances Chapter 17 – Trees and Vegetation

4. Riceboro – Code of Ordinances Chapter 16, Article VII – Landscape and Tree Protection

5. Walthourville – Code of Ordinances Chapter 119 – Tree Protection and Land Clearing

6. Midway, Allenhurst and Gum Branch – same as for Liberty County

B. Should any definition or provision of this Ordinance conflict with any of the above referenced standards, such conflicting definition or provision of this Ordinance shall not govern in the application and administration of the standard.

Article 405 Drainage Control Sec. 405-1 Applicability

A. All development shall comply with the applicable drainage standards referenced below as currently in effect and as may be amended in the future.

1. Liberty County – Code of Ordinances Chapter 10 – Drainage Control

2. Flemington – Code of Ordinances Chapter 38, Article IV – Drainage Control

3. Hinesville – Code of Ordinances Chapter 6, Article III – Drainage Control, and Hinesville Downtown Stormwater Policy Manual #2013-03

4. Riceboro – Code of Ordinances Chapter 16, Article IV – Drainage Control

5. Walthourville – Code of Ordinances Chapter 105 - Drainage

6. Midway, Allenhurst and Gum Branch – same as for Liberty County

B. Should any definition or provision of this Ordinance conflict with any of the above referenced standards, such conflicting definition or provision of this Ordinance shall not govern in the application and administration of the standard.

Article 406 Flood Damage Prevention Sec. 406-1 Applicability

A. All development shall comply with the applicable flood damage prevention standards referenced below as currently in effect and as may be amended in the future.

1. Liberty County – Code of Ordinances Chapter 8, Article III – Flood Damage Prevention

2. Flemington – Code of Ordinances Chapter 42 - Floods

3. Hinesville – Code of Ordinances Chapter 5, Article VI – Flood Damage Prevention

4. Riceboro – Code of Ordinances Chapter 16, Article II – Flood Damage Prevention

5. Walthourville – Code of Ordinances Chapter 107 - Floods

6. Midway – Code of Ordinances Chapter 12, Article II – Flood Prevention and Damage Control

7. Allenhurst and Gum Branch – same as for Liberty County

B. Should any definition or provision of this Ordinance conflict with any of the above referenced standards, such conflicting definition or provision of this Ordinance shall not govern in the application and administration of the standard.

Article 407 Wetland Protection Sec. 407-1 Applicability

A. All development shall comply with the applicable wetland protection standards referenced below as currently in effect and as may be amended in the future.

1. Liberty County – Code of Ordinances Chapter 8, Article V – Wetlands Protection

2. Flemington – Code of Ordinances Chapter 38, Article III - Wetlands

3. Hinesville – Code of Ordinances Chapter 5, Article VII, Division 1 – Wetlands Protection

4. Riceboro – Code of Ordinances Chapter 16, Article VI – Wetland Protection

5. Walthourville – Code of Ordinances Chapter 123 - Wetlands

6. Midway, Allenhurst and Gum Branch – same as for Liberty County

B. Should any definition or provision of this Ordinance conflict with any of the above referenced standards, such conflicting definition or provision of this Ordinance shall not govern in the application and administration of the standard.

Article 408 Groundwater Protection Sec. 408-1 Applicability

A. All development shall comply with the applicable groundwater protection standards referenced below as currently in effect and as may be amended in the future.

1. Liberty County – Code of Ordinances Chapter 88 – Groundwater Recharge Area Protection

2. Hinesville – Code of Ordinances Chapter 5, Article VII, Division 2 – Groundwater Recharge Area Protection

3. Riceboro – Code of Ordinances Chapter 16, Article V – Wellhead Protection

4. Walthourville – Code of Ordinances Chapter 109 - Groundwater

5. Flemington, Midway, Allenhurst and Gum Branch – same as for Liberty County

B. Should any definition or provision of this Ordinance conflict with any of the above referenced standards, such conflicting definition or provision of this Ordinance shall not govern in the application and administration of the standard.

Article 409 Erosion, Sediment and Pollution Control Sec. 409-1 Applicability

A. All development shall comply with the applicable erosion, sedimentation and pollution control standards referenced below as currently in effect and as may be amended in the future.

1. Liberty County – Code of Ordinances Chapter 8, Article IV – Soil Erosion, Sedimentation and Pollution Control

2. Flemington – Code of Ordinances Chapter 38, Article II - Soil Erosion, Sedimentation and Pollution Control

3. Hinesville – Code of Ordinances Chapter 6, Article IV – Soil Erosion, Sedimentation and Pollution Control

4. Riceboro – Code of Ordinances Chapter 16, Article III – Soil Erosion, Sedimentation and Pollution Control

5. Walthourville – Code of Ordinances Chapter 115 – Soil Erosion, Sedimentation and Pollution Control

6. Midway, Allenhurst and Gum Branch – same as for Liberty County

B. Should any definition or provision of this Ordinance conflict with any of the above referenced standards, such conflicting definition or provision of this Ordinance shall not govern in the application and administration of the standard.

Division V Subdivisions Article 501 Subdivision General Provisions Article 501 Table of Contents Sec. 501-1 Purpose The public health, safety, economy, good order, appearance, convenience, morals, and general welfare require the harmonious, orderly and progressive development of land within Liberty County. In furtherance of the general intent of this Ordinance, the regulation of land subdivision by municipal and county governing authorities is authorized for the following purposes, among others:

A. To encourage the development of economically sound, sustainable and stable municipalities and the County.

B. To ensure the timely provision of required streets, utilities, and other facilities and services to new land developments.

C. To ensure the adequate provision of safe and convenient traffic access and circulation, both vehicular and pedestrian, in and through new land developments.

D. To ensure the provision of needed public open spaces and building sites in new land developments through the dedication or reservation of land for recreational, educational, and other public purposes.

E. To ensure, in general, the wise and timely development of new areas, in harmony with the comprehensive plan of the municipalities and the County.

Sec. 501-2 Applicability and Exemptions

A. For the purposes of this Article, the term “subdivision” as herein used and defined in Division VII shall include PUDs which involve the subdivision of land.

B. General applicability

1. Subdivision approval is required prior to the sale, transfer of ownership or lease of any portion of a parcel of land within the jurisdiction of this Ordinance unless otherwise exempted below.

2. For major subdivisions, the preliminary plat and construction plans shall be approved prior to making any street improvements or installing utilities. Lots within the subdivision shall not be sold until the final plat has been recorded and the record drawings have been approved.

C. Exemptions – The above notwithstanding the following are exempt from subdivision review and approval:

1. Merging of parcels in their entirety (i.e. recombination plats).

2. Lot line adjustments between adjacent lots where neither lot is part of an approved subdivision, the beginning and ending number of lots is the same and all lots are conforming.

3. The granting of rights-of-way or easements other than for access.

Sec. 501-3 Review and Decision Authorities

A. Subdivisions have two components: a plat showing the new lots, street rights-of-way, easements, dedications and the boundaries of other such features and, for major subdivisions, construction plans showing all the required improvements. [See Sec. 501-5 for descriptions of the various types of subdivisions.]

B. Preliminary and final plats for subdivisions shall be reviewed by LCPC.

C. Minor subdivisions are acted upon by LCPC.

D. For major subdivisions, the Planning Commission shall provide a recommendation regarding the preliminary plat to the governing authority which shall act on the plat. If there are no substantial changes between the preliminary and final plats, a recommendation from the Planning Commission is not required before action is taken by the governing authority on the final plat.

E. Construction plans and record drawings for the required improvements shall be reviewed and approved by LCPC except for subdivisions in Liberty County, in which case they shall be reviewed and approved by staff of the County Building and Licensing Department. The applicable staff is referred to in this Division as the “plan reviewer.” This notwithstanding, Liberty County may delegate its plan review responsibilities to LCPC at any time.

Sec. 501-4 Decisions and Conditions of Approval

A. Approval shall be granted as provided herein if the project meets the applicable criteria and/or requirements specified in this Division.

B. The following standard conditions of approval shall be imposed for all plats:

1. The applicant must obtain all required local, state and federal licenses and permits prior to commencement of any construction.

2. All plans, documents, materials, and statements contained or implied in this application are considered a condition of approval.

3. No change or deviation from the conditions of approval are allowed without prior notification and approval of the plan reviewer and the approving governing authority.

C. A standard condition of approval for all construction plans is that substantial modifications to the plans shall require review and approval by the plan reviewer.

D. Additional special conditions may be imposed on any decision provided it is relevant to an applicable requirement and is needed for a project to meet that requirement.

Sec. 501-5 Types of Subdivisions

A. Minor subdivisions

1. The types of conveyances described below shall be considered minor subdivisions.

Simple conveyances are applicable in all jurisdictions. The remaining conveyances (family, minor rural land and shared access) are only applicable in Liberty County and Riceboro.

a. Simple conveyances - Subdivisions which meet all the following criteria are considered minor subdivisions:

i. All lots have frontage on an existing public or private street.

ii. If on an existing public street, no improvements to the street are proposed.

iii. If on a private street, the street shall remain private (i.e. not be dedicated to the municipality).

iv. No new streets are proposed.

v. No new construction or expansion of or improvements to municipal, public or community water, sewer, stormwater, reuse water or other similar utilities are proposed.

vi. No dedications to the municipality are proposed.

b. Family conveyances (Applicable only in Liberty County and Riceboro) Subdivisions which meet the criteria below are considered minor subdivisions.

The original parcel and resulting lots in a family conveyance subdivision may be further subdivided but not as a family conveyance subdivision. As set forth in Sec. 501-9 [Exceptions], a family conveyance subdivision may be allowed an exception from the design requirements.

i. The applicant certifies to LCPC that the applicant's intended division of the land is only for conveyance to one (1) or more family members. A

"family member" is defined as the applicant's spouse, natural or adopted children, stepchildren, father, mother, sister, brother or grandchildren.

ii. The land is currently zoned agricultural (A-1) or agricultural residential (AR1).

iii. The resulting lots will be used for single-family residential or agricultural uses.

iv. The division of land must be into fifteen (15) or fewer lots.

v. No new public streets or other public infrastructure improvements are involved.

vi. All resulting lots shall be a minimum of one (1) acre in area.

vii. Either the conditions of paragraphs (1) or (2) below shall be met:

(1) All lots have frontage

(a) The resulting lots meet the required frontage for the zoning of the property, or

(b) There are only two resulting lots, each with the maximum feasible direct frontage on an existing county or public road, but in no cases shall the frontage be less than thirty (30) feet.

(2) Not all lots have frontage

(a) If not all of the resultant lots have direct access that meet the required frontage for the zoning district to an existing public

street, then the plat shall include a permanent, nonexclusive 60- foot access easement from an existing public street to all lots which do not have access with required frontage to existing public streets, and the easement is otherwise equal to the standard of the governing authority in which the division of land is being made.

(b) All resultant lots abutting such platted access easement shall include a disclosure that the easement or street shall be

maintained by the owners of the abutting lots within the subdivision and the governing authority has no responsibility whatsoever for its maintenance and repair until and unless it is improved to approved street standards at the abutting property owners’ expense and dedicated and accepted by the governing authority.

c. Minor rural land Conveyances (Applicable only in Liberty County and Riceboro) Subdivisions which meet the criteria below are considered minor subdivisions.

The original parcel and resulting lots in a minor rural land conveyance subdivision may be further subdivided but not as a minor rural land conveyance subdivision.

i. The land is currently zoned agricultural (A-1) or agricultural residential (AR1).

ii. The land may be divided into no more than ten (10) lots.

iii. Minimum parcel size shall be five (5) acres and the minimum lot width shall be one hundred fifty (150) feet.

iv. If all resulting lots do not have direct access that meet the required 150- foot frontage to an existing public street, then the plat shall include a permanent, nonexclusive 60-foot access easement from an existing public street to all lots which do not have access with required frontage to existing public streets, and the easement is otherwise equal to the standard of the governing authority in which the division of land is being made.

v. All resultant lots abutting the platted access easement in subparagraph (iv) above shall include a disclosure that the easement or street shall be maintained by the owners of the abutting lots within the subdivision and the governing authority has no responsibility whatsoever for its maintenance and repair until and unless it is improved to approved street standards at the abutting property owners’ expense and dedicated and accepted by the governing authority.

vi. In order to ensure the proper provision of emergency or other services by the county or other entities, when any dwelling units are constructed on any lot served by the easement described in above, no certificate of occupancy shall be given until a street meeting the standards contained in Sec. 504- 7(G) [Unpaved minor streets] is constructed by the property owners. All such streets shall be private streets and meet all requirements for a private street exception (see Sec. 501-9 [Exceptions], other than paving.

d. Shared access conveyances (Applicable only in Liberty County and Riceboro) It shall be considered a minor subdivision if a minimum 30-foot-wide exclusive driveway access easement is proposed to serve not more than two lots in A-1 and AR-1 zoned areas. The two resulting lots shall share the common exclusive driveway access easement and shall not be further subdivided in the future unless the driveway easement is upgraded to the applicable standards for a public or private road.

2. Minor subdivisions shall not require a sketch review or preliminary plat approval.

3. Final plats for minor subdivisions shall comply with the application and plat requirements in Article 503 [Final Review].

4. Final plats shall be approved by LCPC if all the lots meet the lot standards of the applicable zoning district and any other applicable requirements of this Ordinance.

B. Major subdivisions Major subdivisions are all subdivisions that are not minor and shall comply with the requirements of this Division.

C. Conservation subdivisions A conservation subdivision is a form of subdivision that permits flexibility of design in order to promote environmentally sensitive and efficient uses of the land. With land subdivided through a conservation subdivision regulation, the local government can preserve unique or sensitive natural resources such as groundwater, floodplains, wetlands, streams, steep slopes, woodlands and wildlife habitat. Conservation subdivisions enable clustering of houses and structures on less environmentally sensitive soils which will reduce the amount of infrastructure (including paved surfaces and utility easements) necessary for residential development. The procedure for review and approval of conservation subdivisions is included in Article 505 [Conservation Subdivisions].

Sec. 501-6 Amendments to Approved Subdivisions Plats

A. Minor amendments – Minor amendments include modifications which are not considered major amendments. Minor amendments to an approved final plat shall be reviewed by LCPC which shall approve the amended plat if it conforms to the requirements of this Division.

B. Major amendments

1. Any of the following shall be considered major amendments:

a. An increase in the number of lots.

b. Significant modification to the basic layout of the street system such as removal of a connection, realignment of a street, change of a cul-de-sac from temporary to permanent, or change in the width of the street or its ROW.

c. A reduction or elimination of a designated common area, feature or amenity that was an essential element of the project or required by the general development plan (for a PUD).

d. A modification to any special condition of approval.

e. A change of a required improvement that necessitates a change to an easement.

2. Major amendments to an approved final plat shall require the applicant to resubmit the subdivision plat for review by LCPC and action by the governing authority (Planning Commission recommendation not required).

3. If the amendment relates to a requirement or provision that has changed since the original approval, it shall conform to the new requirement or provision to the extent feasible.

Sec. 501-7 Amendments to Approved Construction Plans It is understood that field adjustments are likely during construction. However, if such adjustments result in substantial changes to the approved plans, PRIOR to implementing the adjustments, the applicant shall inform the plan reviewer of the changes who shall determine if review and approval of the changes are warranted. Examples of substantial changes include changing the size of drainage facilities, changing pipe sizes or locations, changing location or type of streetlight, etc.

Sec. 501-8 Variances

A. An applicant may request in writing a variance from the design requirements of this Division and the governing authority shall be authorized to grant a variance, upon hearing a recommendation of the Planning Commission. Such variances, and the reasons for granting them, shall be entered into the minutes of the governing authority.

B. A variance shall be granted if the applicant can demonstrate to the satisfaction of the governing authority that ALL the criteria below are met. In rendering a decision in favor of the applicant, the governing authority may attach such conditions it considers necessary and appropriate under the circumstances.

1. There are unique physical circumstances or conditions, including irregularity, narrowness or shallowness of lot size or shape, or exceptional topographical or other physical conditions peculiar to the particular property;

2. The application of the requirements to this particular property would create an unnecessary hardship;

3. The variance, if granted, represents the minimum variance that will afford relief and will represent the least modification possible; and

4. The variance, if granted, would not cause substantial detriment to the public good or impair the purposes and intent of the Division.

Sec. 501-9 Exceptions

A. Paving, sidewalks and private streets (Not applicable in Hinesville) To promote the public welfare and enhance the safety and health of the public, it may be in the best interests of the municipality to modify or provide exceptions to the development and design standards below. Requests for exceptions shall be made by the applicant in writing and action taken by the governing authority upon hearing the recommendation of the LCPC.

Such action shall be to grant the exception if it meets the applicable criteria and provided the intent and purpose of this Ordinance are not violated. All exceptions, and the reasons for granting them, shall be entered into the minutes of the governing authority.

1. Paving and sidewalks - Subdivisions containing not more than 10 residential lots may be granted an exception from the paving and sidewalk requirements of this Division provided the following conditions are met:

a. Minimum lot size shall be 43,560 SF (one acre) and the minimum lot width shall be 100 feet.

b. The subdivision shall be restricted from further subdivision or extension until the street is paved in accordance with the design standards in effect at the time of application.

c. The future paving of any street in the subdivision will be at the abutting property owners' expense.

d. The length of all roads exempted under the provisions of this Article are not longer than 2,500 feet including any cul-de-sac.

e. All streets shall be private streets and meet all requirements for a private street exception below, other than paving.

2. Private streets - Private streets may be considered as an exception if they meet all the following conditions:

a. Private streets shall meet the requirements of a public street with respect to platting, construction of infrastructure and inspections.

b. All private streets and street name markers shall be maintained by the owners of the property within such subdivisions and the governing authority has no responsibility whatsoever for their maintenance and repair until and unless the street is dedicated and accepted by the governing authority as provided for herein.

c. All lots or parcels abutting any private street subsequently sold following this exception shall include a disclosure that the street is not a public street, and the street shall be maintained by the owners of the property within such subdivisions and the governing authority has no responsibility whatsoever for their maintenance and repair until and unless the street dedicated and accepted by the governing authority as provided for herein.

d. A property owners' association for all properties that have a right of enjoyment of the private streets shall be created to maintain all private streets, shall be filed with the clerk of superior court and, as a minimum, shall provide for:

i. mandatory and automatic membership in the property owners' association before any individual properties are sold;

ii. all owners to have equal access and right to use all shared private facilities;

iii. perpetual and continued maintenance of the private streets and any open space;

iv. bond instruments to ensure maintenance of streets and common areas;

v. bond or tax liability in the case of default;

vi. the method of assessment of dues;

vii. maintenance and related costs; and viii. restoration in the event of damage or destruction.

e. Maintenance bond

i. A perpetual maintenance bond with the municipality as the beneficiary as is required for the completed paving, curb and gutter, sidewalks, drainage, water and sewer facilities, and other required improvements. The bond shall be written in the amount of 25% percent of the construction cost of the work.

The amount of the maintenance bond shall be reviewed and approved by the plan reviewer as sufficient to cover maintenance.

ii. The bond may be released or reduced only if the governing authority accepts any or all improvements for maintenance.

f. Failure to maintain

i. If the property owners' association fails to maintain the private streets and common property in a reasonable condition, the governing authority shall serve written notice upon the association and upon the individual property owners, setting forth the manner in which the organization has failed to maintain common open space and private streets in a reasonable condition.

The notice shall include a demand that these deficiencies of maintenance are corrected within thirty (30) days of the notice.

ii. If the deficiencies are not corrected within thirty (30) days, the municipality, in order to preserve the taxable values of the properties within the development and to prevent the common open space and private streets from becoming a public nuisance, may enter upon the common open space and private streets and maintain it for one year and thereafter until the association is prepared to provide maintenance. The cost of this

maintenance by the municipality shall be assessed against the aforementioned maintenance bond or, if the bond has been allowed to lapse, the cost shall be assessed against all properties within the development that have a right of enjoyment of the private streets and shall become a lien upon the properties.

g. Private streets shall always remain open for police, fire, ambulance, and other vehicles of all government agencies.

h. Dedication and acceptance of private streets

i. The property owners’ association may petition the municipality to accept the private streets, but the municipality is under no obligation to do so.

ii. In order for the municipality to consider accepting the streets, the streets and any other associated improvements (sidewalks, curb,

gutters, signage, stripping, etc.) shall be brought up to current standards.

B. Family conveyance (Applicable only in Liberty County and Riceboro)

1. The improvements as required by this Division may be delayed or waived by the governing authority when the applicant certifies to LCPC that the applicant's intended division of the land is only for conveyance to one (1) or more family members. Such certification shall be in a standard form approved by and include any attachments required by LCPC. (A "family member" is defined as the applicant's spouse, natural or adopted children, stepchildren, father, mother, sister, brother or grandchildren.)

2. In all cases the family conveyance exception must be approved by the governing authority, however, this exemption for the original parcel and the parcels resulting for the subdivision will be allowed only one (1) time. Furthermore, family conveyance subdivisions must comply with the following requirements:

a. Access roads into the subdivision must be accessible to all lots. The road shall be in a 60-foot right-of-way and shall have a minimum of two (2) standard travel lanes.

b. The lot size and required frontage must meet the requirements of the zoning of the property.

c. Subdivision must be accompanied by an affidavit that the road is nonconforming.

d. Should more than fifty (50) percent of the property resulting from the subdivision exemption be conveyed to someone other than a certified family member, the required improvements in this ordinance must be installed at the expense of the property owner. The following requirements shall apply:

i. No building permit shall be issued until such improvements are complete and accepted by the governing authority.

ii. No manufactured home or other structure shall be placed on any lot said subdivision until such required improvements are complete and accepted by the governing authority.

iii. No lot of the subdivision shall be occupied or inhabited until such improvements are complete and accepted by the governing authority.

Article 502 Preliminary Review Article 502 Table of Contents Sec. 502-1 Complete Applications Except for sketch reviews, no review will take place until an application has been deemed complete. A complete application shall include, as a minimum, the following:

A. Forms – general engineering review application and any other forms provided to the applicant.

B. Fee as provided for in Div. VII.

C. Preliminary plat and construction plans – one full-sized paper copy and one electronic copy which conforms to the requirements in Sec. 502-5.

D. Other submittals required to ascertain compliance with this Ordinance (i.e. hydrology report, etc.).

Sec. 502-2 Sketch Review

A. Prior to the filing of a preliminary plat and plans, the applicant is encouraged to submit a sketch plan of the proposed subdivision. The sketch plan may be a simple freehand drawing showing the subdivision and its relation to the surrounding area.

B. The purposes of the sketch plan are to assist the applicant prior to extensive site planning for the preparation of the preliminary plat, to enable the applicant to become familiar with the regulations affecting the land to be subdivided, to outline what submittals will likely be required and to answer basic questions of procedure and the like.

Sec. 502-3 Preliminary Plat Review Procedure

A. General

1. Preliminary plats shall be prepared by a surveyor licensed in the State of Georgia and shall conform to the design requirements and required improvements provisions in Article 504 [Design and Improvements].

2. The applicant or authorized representative shall be present at all meetings at which the plat is to be considered. If the applicant or authorized representative is not present, the matter may be tabled.

B. Review for conformance (LCPC)

1. The plat shall be forwarded to and comments solicited from municipal officials such as the manager, mayor or administrator, building inspector, emergency services personnel and utility department personnel.

2. LCPC shall review the plat for conformance to the requirements of this Division and all applicable provisions of this Ordinance. Any deficiencies or comments shall be provided to and addressed by the applicant. Upon a determination that the plat conforms to all requirements, the applicant shall submit an electronic copy and up to 4 paper copies as required by this Ordinance or as requested by LCPC.

C. Review and recommendation (Planning Commission) Upon receipt of the above-referenced electronic copy of the plat, it shall be placed on the agenda of the next available Planning Commission meeting. At the meeting, LCPC shall present the plat and its recommended action. The Planning Commission shall recommend a course of action for the governing authority.

D. Action (governing authority) The Planning Commission’s recommendation shall be presented to the governing authority at its next available regular meeting. The governing authority shall either approve, with or without conditions, or deny the plat.

Sec. 502-4 Construction Plan Review Procedure

A. Review and approval

1. Construction plans shall be prepared by a professional engineer registered in the State of Georgia and shall conform to the design requirements and required improvements provisions in Article 504 [Design and Improvements] and other applicable provisions of this Ordinance.

2. The plans shall be forwarded to, and comments solicited from, appropriate municipal officials such as the manager, mayor or administrator, building inspector, emergency services personnel and utility department personnel.

3. The plan reviewer shall review the plans for completeness and conformance to the requirements of this Division and all applicable provisions of this Ordinance. Any deficiencies or comments shall be provided to and addressed by the applicant.

4. The plans shall be approved by the plan reviewer, with or without conditions, if the plans conform to this Division and all applicable provisions of this Ordinance. Upon approval, the applicant shall submit an electronic copy and up to 3 paper copies marked “For Construction”. No construction shall commence until the plans have been approved.

5. Approval disclaimers

a. Approval of plans does not relieve the owner/developer, designer, and contractor or their representatives from their individual or collective responsibilities to comply with provisions of other local, state, and federal regulations.

b. All design liability remains with the professional engineer who signed and sealed the approved plans and supporting documents and such liability cannot be assumed or assigned to the plan reviewer.

c. Approval of the plans is not to be construed as a check of every item in the submitted documents and does not prevent the plan reviewer from hereafter requiring corrections and/or addressing of omissions in the submitted documents and/or construction plans.

B. Preconstruction meeting A preconstruction meeting is required and will not be scheduled until, at a minimum, the electronic and paper copies of the approved plans indicated above have been received and, as applicable, a Notice of Intent, an application for a Land Disturbing Activity (LDA) permit has been received, the initial best management practices (BMPs) for erosion, sediment and pollution control as shown on the plans have been installed and an engineer has certified these BMPs have been installed correctly and in accordance with the plans. No construction shall commence until the construction plans have been approved and, if required, the LDA permit has been issued.

C. Inspections Inspections by the plan reviewer may be conducted throughout the construction of the improvements. Witnessing of testing (i.e. pressure tests, proof rolling, etc.) for improvements that are to be dedicated to the municipality is required unless waived by the plan reviewer.

Sec. 502-5 Preliminary Plat and Construction Plan Requirements The preliminary plat and construction plans shall include, at a minimum, the information listed below. Additional site or project specific information may also be required if pertinent to demonstrating compliance with the standards.

A. General requirements

1. The survey and plat shall conform to State Board of Professional Engineers and Land Surveyors Rule 180-7 “Technical Standards for Property Surveys” and OCGA §15-6- 67 “Recordation of plats and condominium plans; specifications”, respectively.

2. Plat shall be at a sufficient scale to permit the study of all elements of the plat but shall not be less than 1 in. = 100 ft. Scale shall be stated and shown graphically.

3. Paper copies of the plat shall not exceed 2’ x 3’ in size.

4. Vicinity map showing the relationship of the subdivision to the surrounding area.

5. Acreage to be subdivided.

6. A drawing legend that includes, at a minimum, symbols used in the plans.

B. Existing conditions

1. Contours based on mean sea level and at vertical intervals of not more than two feet.

2. Applicable zoning district and lot development standards.

3. Natural features such as surface water bodies, wetlands (with indication if they are jurisdictional), etc.

4. Manmade features such as existing buildings, foundations, drainage facilities, utilities, etc.

5. Limits of flood zones and floodways, elevations associated with a Zone AE and indication if a LOMC will be sought that will change the flood zone limits and/or elevations of a Zone AE.

6. Adjoining property lines within 50 feet of the subject property, and parcel ID number and names of deed record owners of the land adjacent to the site.

7. Rights-of-way and easements on the subject property and on adjacent property if they extend onto them.

8. Municipal boundaries.

9. In case of a modification to an approved subdivision plat, the approved plat with the proposed subdivision superimposed thereon.

C. Proposed conditions

1. Layouts of streets, their associated rights-of-way, centerline lengths and total area, and approved street name or temporary designation.

2. Layout of all lots, including building setback lines and dimensions.

3. A table providing total size and all other information related to the lot standards for each lot such as usable size, width, etc.

4. All easements with indication of width and purpose.

5. All proposed dedications to the municipality with description for same.

6. All other areas such as common areas (i.e. not building lots or areas to be dedicated to the municipality) with indication of intended purposes and ownership.

7. Designation of proposed use of all lots to be used for something other than singlefamily residential (if any).

8. Layout of utilities and their associated easements.

9. If the lots will be served by on-site sewage management systems, (OSSMS), documentation from the Liberty County Health Dept. shall be provided which indicates the project has been reviewed and it finds the soils are conducive for the installation of OSSMS or other such similar finding.

10. Any other information related to required improvements and needed to ascertain compliance with the Article 504 [Design and Improvements].

Article 503 Final Review Article 503 Table of Contents Sec. 503-1 Complete Applications Figure 503.1 Certification Block for Ownership and Dedication

(A) for individual owners

(B) for corporate owners Figure 503.2 Certification Block for Compliance and Improvements

(A) if all improvements installed

(B) if installation is pending Figure 503.3 Certification Block for Approval by Governing Authority Figure 503.4 Certification Block for On-Site Sewage Management Systems (OSSMS) Figure 503.5 Certification Block for the Planning Commission

Sec. 503-1 Complete Applications No review will take place until an application has been deemed complete. A complete application shall include, as a minimum, the following:

A. General engineering review application and any other forms provided to the applicant.

B. Fees as required by the fee schedule.

C. One full-sized paper copy and one electronic copy of the final plat which conforms to the requirements in Sec. 503-4.

D. One full-sized paper copy and one electronic copy of the record drawings which conforms to the requirements in Sec. 503-6.

E. Close-out requirements as specified in Sec. 503-5.

Sec. 503-2 Final Plat Review Procedure

A. Review for conformance (LCPC)

1. The plat shall be forwarded to and comments solicited from municipal officials such as the manager, mayor or administrator, building inspector, emergency services personnel and utility department personnel.

2. LCPC shall review the plat for conformance to the requirements of this Division and all applicable provisions of this Ordinance. Any deficiencies or comments shall be provided to and addressed by the applicant. Upon a determination that the plat conforms to all requirements, the applicant shall submit an electronic copy and up to 4 paper copies as required by this Ordinance or as requested by LCPC.

B. Review and recommendation (Planning Commission)

1. Upon receipt of the above-referenced electronic copy of the plat, it shall be placed on the agenda of the next available Planning Commission meeting. At the meeting, LCPC shall present the plat and its recommended action. The Planning Commission shall recommend a course of action for the governing authority.

2. This notwithstanding, if there are no substantial changes between the preliminary and final plats, a recommendation from the Planning Commission is not required before action is taken by the governing authority on the final plat. In which case, LCPC shall provide a recommendation to the governing authority.

C. Action (governing authority)

1. The Planning Commission’s or LCPC’s recommendation, as applicable, shall be presented to the governing authority at its next available regular meeting. The governing authority shall either approve, with or without conditions, or deny the plat.

2. The applicant or authorized representative shall be present at all meetings at which the plat is to be considered. If the applicant or authorized representative is not present, the matter may be tabled.

D. Recording of final plat Final plats shall not be recorded until the requirements of this Article have been met including but not limited to acceptance of record drawings, receipt of sureties, site stabilized, monuments and markers installed, etc., as applicable.

Sec. 503-3 Survey Requirements

A. Surveys of the subdivision shall be prepared by a surveyor licensed in the State of Georgia and shall conform to the State Board of Registration for Professional Engineers and Land Surveyors Rule 180-7 “Technical Standards for Property Surveys” as currently in effect or as may be amended in the future.

B. Additionally, the survey shall also include at least two monuments designed and designated as control corners which comply with the requirements below. If the subdivision is final platted in phases, the final plat for each phase shall provide these two corner corners.

1. All control corners monuments shall be constructed of concrete and shall be at least four inches in diameter or square and not less than three feet in length.

2. Each monument shall have imbedded in its top or attached by a suitable means, a metal plate of noncorrosive materials and marked plainly with the point, the surveyor's registration number, the month and year it was installed and the words "control corner."

3. Each control corner shall be designated by state plan coordinates which comply with Rule 180-7-.06(2).

4. At least one control corner shall include a permanent benchmark elevation referenced to mean sea level datum for all subdivisions within 15 or more lots or any subdivision located in or adjacent to a designated flood zone other than Zone X.

Sec. 503-4 Final Plat Requirements Final plats shall conform to OCGA §15-6-67 “Recordation of plats and condominium plans;

specifications” as currently in effect and as may be amended in the future. Additionally, they shall include the items below, as applicable.

A. General

1. Layouts of streets and their associated rights-of-way, centerline lengths (per street) and total area, and approved street names.

2. Layout of all lots, including building setback lines and dimensions.

3. A table providing total size and all other information related to the lot standards for each lot such as usable size, width, etc.

4. All easements with indication of width and purpose.

5. All proposed dedications to the municipality with description for same.

6. All other areas such as common areas (i.e. not building lots or areas to be dedicated to the municipality) with indication of intended purposes and ownership.

7. Designation of proposed use of all lots to be used for something other than singlefamily residential (if any).

8. Layout of utilities and their associated rights-of-way.

9. Limits of flood zones and floodways, elevations associated with an AE Zone, current applicable flood map number and effective date, and indication if a LOMC will be sought that will change the flood zone limits and/or elevations of an AE Zone.

B. The applicable surveyor’s certification as required in OCGA §15-6-67(c)(3).