DISTRICT

MINIMUM

LOT SIZE

(SQ. FT.)

MINIMUM

LOT

WIDTH

(FEET)

MAXIMUM

HEIGHT

(FEET)

MAXIMUM

LOT

COVERAGE (%)

MAXIMUM

DENSITY

(UNITS

PER

ACRE)

MINIMUM

HEATED

FLOOR

AREA

PER UNIT

(SQ. FT.)

R-I 12,000/ .275 100 35 30 1.3 1,600

R-II 8,000 80 35 35 2 1,400

R-III 6,000 50 50 35 4 1,200

R-IV 25,000 100 35 40 1 2,200

MHP 88,000 not to exceed 10 acres total development 100 35 40 4, not to exceed 10 acres total development 800 NS** 40,000 50 50 35 12.00 800 HB** 40,000 50 50 60 12.00 800 CB** 40,000 50 50 60 12.00 800

CBD** 40,000 50 50 70 12.00 800

O-P** 7,260 50 35 35 10.00 800 M-1** 21,780 50 100 60 5.00 800 M-2** 21,780 50 150 60 5.00 800 A 130,680 200 150 60 0.33 800

DISTRICT

MINIMUM

LOT SIZE

(SQ. FT.)

MINIMUM

LOT

WIDTH

(FEET)

MAXIMUM

HEIGHT

(FEET)

MAXIMUM

LOT

COVERAGE (%)

MAXIMUM

DENSITY

(UNITS

PER

ACRE)

MINIMUM

HEATED

FLOOR

AREA

PER UNIT

(SQ. FT.)

PDD 40/30 Not to exceed 25% 1100 ** Additional density could be allowed by variance in the form of a credit for consumption of (REUSE) non-potable water usage in business application and/or land application, but will expire upon consumption decline or abandonment of service. To be considered on a case-by-case basis by the Town Council depending upon availability services.

Sustainable Growth Design and Application is intended to allow for the above-mentioned criteria and the application of design & application procedures creating performance based planning as follows: a reduction in infrastructure needs, an enhancement of transportation needs and/or alternatives, improvement of community land use reducing the immediate impact on surrounding property by an increase in overall setbacks for the exterior of the development, enhancement for reduction of environmental impact, requiring submittal of watershed protection, urban reuse, slope and grade study and storm water management with site plan development. This application is not limited to residential application and should be explored for commercial and industrial application. The design and application lend themselves to conservation and allow for new development to be measured for numerous aspects of impact allowing for a reduction in development cost, a reduction in short and long term maintenance, and a benefit to the future property owners in sustaining values to the tax digest and the community taxpayers. Such developments will be considered in the planned development districts.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:alto/zoning/2202@2025-08-25-aee912a0a4

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Alto Zoning Ordinance, Section 2202. Minimum lot width, lot size, floor area and density requirements | Georgia Commons