A. Design areas. For the purpose of this title, the C-D zone is divided into design areas as described in the "Alternative Compliance Guidelines for the CD Zone - Athens-Clarke County, Georgia," (hereinafter "Alternative Compliance Guidelines"), dated June 5, 2007, adopted herein by reference, and available for public inspection in the offices of the Athens-Clarke County Planning Department and the Clerk of Commission.

Downtown Historic District

West Downtown

East Downtown

Dougherty Street

River

West End

North Downtown

B. Design area boundaries. The location and boundaries of the design areas in the Commercial-Downtown (C-D) zoning district listed in paragraph (A.) above are delineated on the Official Zoning Map of Athens-Clarke County, Georgia. The Official Zoning Map of Athens-Clarke County, Georgia, constituting the component part of the Zoning Ordinance of Athens-Clarke County, Georgia, by virtue of and in compliance with section 9-3-3 and section 9-3-6 thereof, is hereby amended by adding the boundaries of said design areas within the C-D zoning district to the Zoning Map, adopted contemporaneously herewith. When uncertainty exists with respect to the location of the boundaries of any design area in the C-D zone, the rules of section 9-3-4, concerning zoning district boundary lines, shall apply in determining design area boundary lines. The boundary limits of individual design areas shall be completely contained within the C-D zone. In the event that a parcel is rezoned to the C-D designation, the Mayor and Commission contemporaneously with such rezoning shall assign a design area to such parcel. Such determination shall be based upon the parcel's proximity to an existing design area and characteristics of the existing design area that are similar to those of the rezoned parcel.

C. Site design standards.

1. Maximum building setbacks. The maximum building setback from a property line adjacent to all street rights-of-way (not including alleys) shall be as follows:

| | | | |----|----|----| | Design Areas | Maximum Setback | Minimum Wall Percentage 1 | | Downtown Historic District | 0 feet | 70% | | West Downtown | 0 feet | 50% | | East Downtown | 0 feet | 50% | | Dougherty Street | 30 feet | 50% | | River | 30 feet | 50% | | West End | 30 feet | 50% | | North Downtown | 30 feet | 50% |

1 The minimum percentage of the front wall plane between the street right-of-way and the maximum building setback line. The maximum length of a wall, set at an angle not exceeding 45 degrees to the street right-of-way and set back further than the maximum front setback line, shall not exceed 50 feet.

2. Parking structures. Any structured parking shall have leasable and occupiable commercial or residential uses between the property line and parking at street level. These other uses shall extend a minimum of 70 percent of the linear street frontage of the structure.

3. Surface parking lots.

a. Accessory surface parking areas shall not be located in the front yard or the side yard adjacent to a street (not including alleys).

b. A surface parking lot as a principal property use shall comply with the following setback requirements:

| | | |-------------------|---------------------| | Design Area | Min. Street Setback | | Historic District | Not Permitted | | West Downtown | 10 feet | | East Downtown | 10 feet | | Dougherty Street | 10 feet | | River | 10 feet | | West End | 10 feet | | North Downtown | 10 feet |

c. A landscape buffer shall have a minimum depth of 10 feet between a street right-of-way (not including alleys) and the parking area. The landscape buffer shall incorporate a sight-obscuring hedge screen, which shall grow to be at least 24 inches and no more than 42 inches higher than the finished grade of the parking area, except for required vision clearance areas. Screen plantings shall be of such size and number to provide the required screening within 12 months after installation. Adequate provisions shall be made to protect plant materials from being damaged by vehicles using the parking area.

d. Surface parking areas shall be shaded by trees in accordance with section 8-7-15(J).

e. Raised pedestrian walkways shall be installed through surface parking areas of 50 or more spaces or more than 100 feet in average width or depth.

f. Surface parking lots with 50 spaces or more shall be divided into separate areas divided by landscaped areas or walkways at least ten feet in width or by a group of buildings.

4. Public sidewalks shall be provided adjacent to a public street along the street frontage.

5. Trash storage areas, mechanical equipment, and similar areas shall be screened from view from adjacent public rights-of-way.

6. Outdoor storage areas and loading facilities shall be screened from view from adjacent public rights-of-way.

7. Transit amenities, bus shelters, and pullouts shall be required in accordance with the Athens-Clarke County Transit Service.

8. Retaining walls in a front yard, rear yard, or side yard adjacent to a public right-of-way or private street shall be set back from a public right-of-way a minimum of two feet for every foot of wall height above three feet in height, as measured parallel to the right-of-way and accounting for any linear changes in height. No portion of a retaining wall shall exceed ten feet in height. A terrace is required between a lower retaining wall and an upper wall and the terrace area shall have a minimum five-foot depth as measured from the upper grade of the lower retaining wall to the base of the upper retaining wall. Retaining walls over five feet in height shall be screened by a landscape buffer meeting the standards of section 9-10-6-D-(4)(b)(3); however, wall art, including murals, sculptural or other decorative treatment of exterior walls may extend for a maximum of 50 percent of the wall length. Acceptable exterior finish materials include, but are not limited to, stucco, split face blocks, brick, stone, glass blocks, curved interlock blocks, wood, tubular steel, wrought iron bars or other grill work, textural or scored poured concrete, engineered "green" or vegetative wall as approved by the planning director, or a combination of these materials. Exposed flat-face CMU blocks and EIFS stucco are prohibited.

9. Chain-link and opaque wood fencing are not allowed in any yard adjacent to a street.

D. Building design standards.

1. Horizontal definition of the building facade. First and second floor levels of a wall of a building that faces a public street shall be horizontally defined with clearly distinguishable horizontal details, which shall extend for a minimum of 70 percent of the wall length. A horizontal element shall define the first floor and the second floor. The required horizontal articulation may be achieved by using one of the following methods:

a. A molding, ornamental trim, window casing or sill that projects a minimum of three inches from the primary wall surface, and/or

b. A setback in the primary wall plane at the second and/or third floor level, a minimum of five feet from the floor below, and/or

c. A permanently affixed canopy, extending a minimum of four feet from the building face, and/or

d. A horizontal fascia that defines floor structure between the first and second floors, and/or

e. An eave of a porch, portico, or other similar element, which extends a minimum of 18 inches from the building face.

Examples of horizontal definition achieved through use of moldings, changes in wall plane, canopies and a spandrel beam. The moldings and canopies shown would each independently meet the requirement for horizontal articulation extending 70 percent of the wall length.

2. Vertical definition of building modules. Vertical definition shall be provided at a minimum of every 40 feet of facade length, using one or more of the following methods:

a. A molding, ornamental trim, or window casing projecting a minimum of three inches from the primary wall surface and is a minimum of three inches wide, and/or

b. A setback in the primary wall plane a minimum of three feet from the building face and for a minimum width of three feet.

3. Primary entrance. The primary public entrance of a building and/or each ground floor tenant space facing a street shall be directly linked to a public sidewalk. For ground-floor dwellings facing a street, a maximum allowance of two tenant spaces may share the same direct link. The primary entrance shall be positioned no more than five feet above the finished grade at the front of the building.

a. Buildings shall incorporate lighting and changes in mass, surface or finish to give emphasis to entrances.

b. Building shall incorporate arcades, roofs, alcoves, porticoes and/or awnings at public entrances that protect pedestrians from the rain and sun.

4. Transparency. A minimum percentage of any wall facing a public street shall have openings accounting for the percentages provided below and use transparent glass in those openings, unless directly associated with open unenclosed parking structures:

Table 1. This was a table in the source. Each line is one of its rows, with its cells in order, separated by a bar. A row may have fewer cells than the table has columns, so read the cells in order, not by column.
  1. Design Area | Ground Floor Levels min. % | Upper Levels min. %
  2. Downtown Historic District | 60% | 20%
  3. West Downtown | 50% | 20%
  4. East Downtown | 50% | 20%
  5. Dougherty Street | 30% | 20%
  6. River | 30% | 20%
  7. West End | 30% | 20%
  8. North Downtown | 30% | 20%

a. Transparency at the ground floor level shall be measured from the finished building grade at the street to ten feet above grade for the entire width of the wall.

b. The following alternative design treatments may be used, singularly or in combination, to meet half of the transparency requirement per elevation at the street level:

(1) A display case, defined as a box with transparent glass facing the street with a solid panel behind for display of products and images of goods and services offered in the area.

(2) Wall art, including murals, sculptural and other decorative treatment of exterior walls.

(3) Landscaping, which is to be at least three feet high at the time of planting and of a type that will produce an opaque, evergreen planting screen capable of growing to a height of at least six feet within three years.

c. Windows must allow views into working areas or lobbies, pedestrian entrances or display areas.

5. Building materials. No more than 25 percent of a wall surface, singularly or in combination, may be of plaster, stucco, or metal sheet siding. Metal siding shall be prohibited on the first floor, except for fabricated architectural metal siding panels with a gauge value of 24 or less and without exposed fasteners after installation is complete.

Plain concrete block (CMU), synthetic stucco (e.g., EFIS), mirror glass, and tinted glass with a tint of 20 percent gray or greater are prohibited exterior building materials.

6. All properties in the "C-D" zone shall have a minimum floor area (FAR) ratio of 0.40. Expansions of existing development for which at least 50 percent of the original structure is retained are exempt from the minimum FAR. Plazas and pedestrian areas, conforming to the standards of section 9-25-8-F.2, shall count as floor area for the purpose of meeting the minimum FAR. Reductions of the lot area calculation shall be allowed for flood plain, bodies of open water, wetlands, riparian buffers, slopes greater than 25 percent, buffers required by section 9-15-3, and public utility easements, if these areas remain vegetative or landscaped.

7. Ground-floor dwellings are permitted in the North Downtown Design Area without a special use permit, subject to the following standards:

A. Each ground-floor dwelling with an exterior elevation facing a street shall have direct pedestrian access to the street and public sidewalk.

B. Ground-floor dwellings shall be a minimum distance of 50 feet from the street listed below, as measured from the nearest wall of the residential unit to the nearest street right-of-way, and have leasable and occupiable nonresidential space between the dwellings and right-of-way of such streets at street level, which shall extend a minimum of 70 percent of the linear street frontage of the structure.

College Avenue

E. Alternative compliance. Except for properties within the Downtown Historic District, applicants may request alternatives to compliance with the design standards of this section through a design review process guided by the separate Alternative Compliance Guidelines for the C-D Zone. Applications for alternative compliance will be processed through the Type III procedure described in Chapter 9-4 (Procedures). The Planning Commission shall review alternative compliance applications in light of any comments received from the public, the intent of the standards of this section, and the applicable design guidelines. An alternative compliance application may be approved upon a finding by the Planning Commission that:

1. The request would result in public benefits greater than any negative impacts; and

2. The request is consistent with the goals, objectives, and policies set forth in the Comprehensive Plan of Athens-Clarke County; and

3. The request is consistent with the attributes of the Downtown and of the Design Area described in the Alternative Compliance Guidelines; and

4. The request conforms to the relevant Alternative Compliance Guidelines.

Projects located within the Downtown Historic District shall be reviewed by the Athens-Clarke County Historic Preservation Commission and be subject to their approval as well as meeting the criteria established in this title. In the event of a conflict between C- D Zone Design Standards and the decision of the Historic Preservation Commission, the historic preservation ordinance shall apply.

History

The history line the source prints at the end of the section.

(Ord. of 6-5-2007, § 5; Ord. of 2-3-2009, §§ 1, 2; Ord. of 2-2-2021(1), §§ 3—10)

Meetings that refer to this section

Found 4: meetings of this government whose minutes or machine transcripts name this section, or an ordinance in its history line, newest first. Found by rule from those records' own words. A reference is a pointer to another record, not a statement that the section applies or was changed.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:athens-clarke/zoning/9-10-6@2026-11-14-111230027a

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Athens-Clarke County unified government Zoning Ordinance, Sec. 9-10-6. Design standards for "C-D" zone | Georgia Commons