--- title: Avondale Estates Zoning Ordinance, Sec. 21-3.2.10. Building design standards collection: local-codes id: local-code:avondale-estates/zoning/21-3.2.10 cite_as: Avondale Estates, Ga., Zoning Ordinance § 21-3.2.10 canonical_url: https://georgiacommons.org/code/local/avondale-estates/zoning/21-3.2.10 md_url: https://georgiacommons.org/code/local/avondale-estates/zoning/21-3.2.10.md text_url: https://georgiacommons.org/code/local/avondale-estates/zoning/21-3.2.10/text source_url: https://library.municode.com/ga/avondale_estates/codes/code_of_ordinances date: 2024-04-17 status: active jurisdiction: city:avondale-estates jurisdiction_name: Avondale Estates place_fips: "1304644" corpus_version: local-codes-avondale-estates-7a4d79de2159 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/avondale-estates/zoning/~appendix-a/~chapter-21/~article-3/~division-3.2.md previous: https://georgiacommons.org/code/local/avondale-estates/zoning/21-3.2.9.md next: https://georgiacommons.org/code/local/avondale-estates/zoning/21-3.2.11.md index: https://georgiacommons.org/code/local/avondale-estates.md branch: zoning edition: As published by Municode, current through 2024-04-17 edition_date_kind: current_through source_publisher: Municode version_id: local-code:avondale-estates/zoning/21-3.2.10@2024-04-17-529ee49c7f --- # Avondale Estates Zoning Ordinance, Sec. 21-3.2.10. Building design standards > As published by Municode, current through 2024-04-17 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A / Chapter 21 - ZONING ORDINANCE / Article 3 - SPECIAL PURPOSE DISTRICTS / Division 3.2 - CENTRAL BUSINESS DISTRICT (CBD) A. Intent. These criteria are intended to address a building's appearance and integration into the central business district. The criteria are intended to elicit high quality materials, enhanced pedestrian experience, an appropriate scale, and a development pattern that effectively implements the city's planning and visioning documents. B. Applicability. The building design regulations of this section apply to all buildings in the CBD, unless otherwise expressly stated. 1. Applicable far;ades. The building design standards apply to all far;:ades visible from the street, facing streets, facing main parking lots, and adjacent to or visible from required open spaces, unless otherwise noted. C. Exterior finish materials. 1. Applicable to all sub-areas: a. Primary building materials shall be used on at least seventy (70) percent of any building far;:ade, b. Secondary building materials may be used on up to thirty (30) percent of any exterior building far;:ade, calculated on the basis of each individual far;:ade. c. Building materials, other than those expressly identified in this Section, may be used on up to ten (10) percent of any exterior building far;:ade, provided they have not been prohibited by this section. d. Material proportion calculations shall not include building foundations, window systems, and doors. Proportions are calculated on the basis of each individual far;:ade. e. Materials shall continue around the corner of the building onto far;:ad es not visible from the public street a minimum depth of one (1) architectural bay. f. Prohibited materials. Synthetic stucco, concrete masonry units (CMU), and vinyl are not permitted as exterior finish materials. g. Building far;:ades shall be constructed of no more than three (3) primary materials and/or colors. Additional materials may be used as secondary, trim, or accent materials. h. Awnings. Plastic and vinyl awnings are prohibited. Materials repurposed into textiles for use on an awning is permitted. 2. Exterior wall finish materials differ by sub-area district as follows: a. CBD-1 materials. 1. Primary: Metal panels and siding; exposed, stained, or painted concrete; exposed wood; and ceramic panels; brick, including full-depth and half-depth masonry brick; and stone. 11. Secondary: EIFS; glass block; phenolic resin panels, metal mesh; brick, including full-depth and half-depth masonry brick. b. CBD-2 materials. 1. Primary: Brick, including full-depth and half-depth masonry brick; stone, including unpainted natural stone, unpainted cast stone having the appearance of natural stone; and unpainted terracotta. 11. Secondary: Metal panels and siding; wood, including natural wood or cement-based artificial wood siding. c. CBD-3 materials. 1. Primary: Brick, including full-depth and half-depth masonry brick; stone, including unpainted natural stone, unpainted cast stone having the appearance of natural stone; and unpainted terracotta. 11. Secondary: Wood, including natural wood or cement-based artificial wood siding; shingles, including wood or cement-based shakes and shingles; or stucco. D. Building articulation. 1. In order to avoid large expanses of flat (one-dimensional) exterior walls along sidewalks, building fa9ades over fifty (50) feet in length along a street, including abutting attached houses, shall incorporate wall projections or recesses a minimum of twelve (12) inches in depth. The combined length of such recesses and projections shall constitute at least twenty (20) percent of the total fa9ade length along the public street. 2. One (1) of the following to divide the fa9ade into vertical divisions at increments no greater than the maximum width dimensions shown for a fa9ade type, as measured along the base of the fa9ade. Required division frequency is identified on table 21-3.2.9 - fa9ade types. a. A change of fa9ade material and window system from grade to roof; or b. Change of building height of at least one (1) story; or c. A change in fa9ade composition and/or architectural style from grade to roof; or d. An open space or pedestrian passage with a minimum width of ten (10) feet and a minimum depth of thirty (30) feet. For blocks greater than four hundred (400) feet long, as permitted in section 21-3.2.8.B - block requirements, this provision is required to satisfy the building massing requirements of this section. e. Similar means intended to convey the impression of separate buildings. f. Change in color alone, window system alone, or setback alone, may not be used to satisfy this requirement. 3. Building roof lines along street-facing fa9ades shall change at least once every two hundred (200) feet of fa9ade length. This change shall occur for a minimum length of twenty (20) feet and be accomplished through at least one (1) of the following: a . A change of roof parapet wall height and material; b. A change of roof cornice design; c. A change in the number of stories; d. A change in roof-shape. E. Blank walls. Blank wall area applies to ground and upper story fa9ades visible from a street (not including an alley) or open space. 1. There shall be no more than twenty (20) feet of blank wall area. 2. Blank wall area can be broken up or interrupted to meet these provisions with any one (1) of the following interventions: a. Fenestration; or b. Substantial material change. Paint color alone does not constitute a material change; or c. Fa9ade articulation greater than twelve (12) inches in depth; or d. Patterns and designs articulated with building materials. § 21-3.2.10 e. f Vertical green walls, made of landscaped material specified for vertical, climbing growth. Signage and murals as permitted in chapter 5 - sign regulations. 3. Blank wall area is measured in linear feet applied in both vertical and horizontal directions. See figure 21-3.2.9.E - blank wall area. ,_ ·-- ~.- .-, .... t·1c-r·_· ---,------~-i~--~-· - . -~· .. ( Figure 21-3.2.9.E - Blank Wall Area F. Residential balconies. 1. Where balconies are incorporated into building design, they shall be integral to the fac;ade . 2. Balconies on stepped-back stories may be independently secured, extending from the fac;ade as a cantilever. 3. Juliet balconies are prohibited. G. Window Systems. 1. 2. 3. Fenestration is the minimum percentage of window and door glass that must cover a fa<;ade, pursuant to table 21-3.2.9 - fa<;ade types. It is calculated based fa<;ade area and by floor. The fa<;ade area used to determine fenestration is measured from the top of the finished door to the top of the finished floor above or top of a roof parapet. Fenestration requirements apply to fa<;ades that abut a public or private street (not including an alley), or a required open space. Glass used to satisfy fenestration requirements shall be unpainted, shall have a transparency (visible light transmission) higher than seventy (70) percent and shall have an external reflectance of less than fifteen (15) percent. Transparency and external light reflectance shall be established using the manufacturer's specifications. A_. Level 1 FFE § 21-3.2.12 Upper Story Fenestration Upper Story Fenestration Ground Floor Fenestration 4. Window frames, sashes, mullions, and similar features that are integral to the window system count towards fenestration requirements. Opaque doors and windows do not. Figure 21-3.2.9.G - Fenestration Calculations 5. No shades, blinds, or other coverings are permitted on the ground floor fenestration of any non-residential building. 6. Grilles, inoperable shutters, and other faux window treatments are prohibited. 7. Window systems shall be recessed from the fa<;ade of the building a minimum of three (3) inches. This reveal shall be accomplished through the design of the window casing reveals and frames. H. Pedestrian access. The pedestrian access regulations of section 21-6.2.13 - pedestrian access and circulation apply.