A. Far;;ade type development standards. Table 21-3.2.9 - fa9ade types outlines site standards, heights, and fa9ade requirements based on each fa9ade type. Section 21-3.2.10 - building design standards provides additional standards applying to all fa9ade types. B. Far;;ade types. The following descriptions and illustrations define the allowable fa9ade types required for all exterior fa9ades in the CBD. l. Attached house. The attached house is a building fa9ade typically made up of several single-family, multi-story units, usually referred to as townhouses, each with its own external entrance. Units are not vertically mixed-use but can accommodate live-work units. Figure 21-3.2.9.B.1 - Attached House Fa~ade Type - Sloped Roof Figure 21-3.2.9.B.2 - Attached House Fa~ade Type - Flat Roof Table 21-3.2.9 - Fafade '.Cypes Reference Attached House laeneral I walk-Up lshopfront Site Standards Min. Street Setback Refer to Supplemental Zone Requirements Table 21-3.2.8 Street Max. Street Setback Refer to Supplemental Zone Requirements Type Dimensions Min. Side & Rear Setbacks - I - I - I - Table 21-3.2.9 - Fcu;ade Types Reference Attached House General Walk-Up Shopfi·ont Uses Ground Floor Uses All CBD uses Commercial All CBD uses Commercia l Uses permitted in uses in CBD uses in CBD CBD per Use Table Uses on other floors Residential All CBD uses All CBD uses 21-5.2.4. uses in CBD Parking Garage use Prohibited directly adjacent to Type A streets and City open Section 21-6.2.5, spaces and parks, unless liner buildings are pro- vided. 21-6.3.4 Design requirements in accordance with Ta ble 21-6.2.5 Design Standards for Parking Garages. Height Ground Story Elevation 0 to 4.5 feet 0 to 4.5 feet 0 to 4.5 feet 0 to 4.5 feet (min./ max. above sidewa lk) Min. Building Height 18 feet 18 feet 18 feet 18 feet Sub-Area Tables: Sec- tion 21-3.2.4, Min. Height per Story 21-3.2.5, 21-3.2.6 Ground Story 9 feet 14 feet 10 feet 14 feet Upper Stories 10 feet 10 feet Fa9ades Min. Fenestration on Type A and B Streets Ground Story 25% CBD-1 60% 25% CBD-1 75% CBD-2/ CBD-3 CBD-2/ CBD-3 40% 50% Table 21-3.2.8 Street Upper Stories 25% CBD-145% Type Dimensions; CBD-2/ CBD-3 21-3.2.10.G - Window 35% Systems; 21-3.2.9.B - Min. Fenestration on All Other Street Types Shopfront Design Stand ards Ground Story 20% 25% 25% 40% Upper Story 25% Required Type A and B 1 per unit 1 per 150' of 1 per 75' of 1 per 75' of Figure 21-3.2. 7 - Street Building Entrances (regardless of front fac;:ade front fac;:ade front fac;:ade Street Typology Map street type) Fac;:ade Divisions 1 per 50 feet 1 per 100 1 per 75 feet 1 per 50 feet Section 21-3.2.10.D - feet Building Design Standards Roof Division 1 per 200 feet 1 per 200 feet 1 per 200 feet 1 per 200 feet Section 21-3.2.10.D - Building Design Standards Figure 21-3.2.9.A.1 Fa~ade Type Development Standards ',- I Jt ---------- --- ----1./ < Figure 21-3.2.9.A.2 Fa~ade Type Development Standards 2. General. A general far;ade is intended to be sited close to the sidewalk but may also allow for open spaces and landscaping between the building and public realm. The building is structured to allow single or multi-story development that typically accommodates non-residential uses, such as hotel or office uses on all stories, or multi-family residential uses. The general far;ade type may accommodate limited amounts of accessory retail and service uses on the ground floor. Figure 21-3.2.9.B.3 General Fa«;ade Type 3. Walk-up. Walk-up fai;ades typically house multi-family uses with ground floor units that have entrances facing a sidewalk or public street. Additionally, the design requirements for walk-up fai;ades establish tenant spaces supportive of retail and other service uses in mixed use environments. ... <:...,. -- . ..... ,.;: ·,. __ _ Figure 21-3.2.9.B.4 Walk-Up Fa~ade Type 4. Shopfront. The shopfront fai,;ade is intended for use as a mixed-use building located close to the sidewalk. The most distinctive element of this fai,;ade type is the ground floor fai,;ade with large amounts of storefront glass, regularly spaced entrances, and intricate architectural elements present in existing historic storefronts, typically for retail and service uses. Figure 21-3.2.9.B.5 Shopfront Fa~ade Type C. Shopfront Design standards. 1. The ground story of all shopfront far;ades in CBD-2 and CBD-3 shall contain the following elements as illustrated in figure 21-3.2.9.C: a. b. C. d. e. f. g. h. Cornice I articulated ffoor line. The cornice visually separates one (1) floor from the adjacent floor(s). The cornice can be articulated with a change of color, pattern, or material. Sign board. A sign board shall be an area between the cornice and window system where a wall sign is placed. The sign board shall be a minimum of two (2) feet in height and shall extend the width of each architectural bay. Transom. Transoms are horizontally articulated windows located below the sign board. The window system shall extend the full width of the architectural bay or tenant space but may be separated by mullions and muntins consistent with the design aesthetic. Grilles are prohibited. Recessed entry. Recessed entries are important to the retail experience to protect the users from inclement weather, increase the amount of space in which to display merchandise, and to ease the transition of users to and from the public realm. Entryways shall be recessed [ ~ -~1'.. . ' [ .l ·--·.! l .. _:.;.J :· .·-,: ~-=•· = ~-~=~· ··-o SIGNAGE -o G ...... iiiiiiiiiiiiiiii__.,.:·•· .... ·.~ i~.T ' ' G --,:ri:-:--,±c·,-o Figure 21-3.2.9.C Shopfront Standards Design from the plane of the shopfront far;ade a minimum of three (3) feet. Display window. Display windows provide frames for retail users to display merchandise and contribute to the active and vibrant character along the historic street front. Display windows shall not be separated with mullions, muntins, or grilles. Bulkhead. Bulkheads shall be a minimum of eighteen (18) inches in height and shall extend the full length of the architectural bay or tenant space. Grilles, other faux features, and metal shopfront window systems shall be prohibited. Fenestration. Fenestration proportions shall comply with table 21-3.2.9 - far;ade types and section 21-3.2.lOG - window systems.