A. General regulations. 1. Outdoor lighting fixtures shall be full cutoff and placed so as to allow no light above the horizontal as measured at the luminaire, except as herein noted in this section (as in the case of period fixtures, cutoff fixtures may be used). 2. Outdoor lighting fixtures shall be located, aimed or shielded to minimize glare and stray light trespassing across lot lines and into the public right-of-way. 3. Flood or spot lamps must be positioned no higher than forty-five (45) degrees above straight down (half-way between the vertical and the horizontal) when the source is visible from any off-site residential property or public roadway but even lower than forty-five (45) degrees, if necessary, in order to facilitate compliance with section 21-6.7.5.D.2. 4. All light fixtures that are required to be shielded shall be installed and maintained in such a manner that the shielding is effective as described herein for fully shielded fixtures. 5. Lighting on sites consisting of multiple uses shall conform to the standards of the respective uses, and where a conflict exists, with the more restrictive provisions. 6. Illumination levels are measured from any height and orientation of the measuring device at any location along the property line except the lighting of parking lots must be measured at grade with the meter sensor held horizontally at the surface. 7. Maximum illuminance levels on a subject property shall meet the standards in table 21-6.7.5.A.7 - maximum perimeter illuminance in accordance with the use adjacent to the subject property. Tab.le 2.1-6. 7.5.A. 7. - Maxim.um Perimeter Flluminance Adjacent Use Maximum Foot-candles At property line abutting a residential or an agricultural use 0.5 At property line abutting an institutional use 1.0 At property line abutting a commercial or industrial use 1.5 8. Parking lot illuminance levels on a subject property shall meet the standards in table 21-6.7.5.A.8 - parking lot illuminance standards in accordance with the use adjacent to the subject property. Table 21-6. 7.5.A.8 - Parking Let Illuminance Standards Use of Subject Lot Minimum Average Maximum Foot-candles Foot-candles Foot-candles Residential uses 0.5 2.0-3.0 4.0 Institutional and Agricultural uses 1.0 3.0-4.0 6.0 Commercial uses 2.0 6.0- 7.0 12.0 Industrial uses 1.0 4.0-5.0 8.0 B. Specific uses and activities. This subsection establishes supplemental lighting regulations for specific types of uses and activities. All lighting not directly associated with the special use areas designated below shall comply with all other applicable regulations of this division. l. Outdoor sports, recreation fields and performance areas. Lighting of outdoor recreational facilities (public or private), such as, but not limited to, outdoor athletic fields, courts, tracks, special event or show areas shall comply with table 21-6.7.5.B - light trespass limitations for sports lighting and the following regulations: a. Facilities designed for municipal leagues, elementary to high school levels of play and training fields for recreational or social levels of play, college play, semi-professional, professional or national levels of play shall utilize luminaries with minimal up light consistent with the illumination constraints of the design. Where fully shielded fixtures are not utilized, acceptable luminaries include only those that: 1. Are provided with internal and/or external glare control louvers or lenses, and are installed so as to minimize up light and off-site light trespass and glare, and 11. All lighting installations shall be designed to achieve the illuminance levels for the activity as recommended by the Illuminating Engineering Society of North America (IESNA RP-6). 2. All events shall be scheduled so as to complete all activity no later than 10:30 p.m. Illumination of the playing field, court or track is permitted after the curfew only to conclude a scheduled event that was unable to conclude before the curfew due to unusual circumstances. Field lighting for these facilities must be turned off within thirty (30) minutes of completion of the last event of the night. 3. All light poles shall be set back a minimum sixty (60) feet from any residential property line or right-of-way. Table 21-6.7.5.B - L,il(ht Trespass Limitations for Sports Lighting Environmental Zone Pre-Curfew Limit Post-Curfew Limit Degrees Above Nadir (not to exceed 12,000 candela from a single fixture) El Not allowed 0.0 max vertical Not allowed E2 0.25 max horizontal 0.10 max vertica l 82 degrees 1.0 max vertical E3 0.5 max horizontal 0.30 max vertical 85 degrees 2.0 max vertical E4 0. 75 max horizonta l 0.60 max vertical 88 degrees 3.0 max vertical El = Areas with intrinsically da rk landscapes, such as national parks, a reas of outstanding natural beauty, etc. E2 = Areas of low ambient brightness, including sensitive residential areas. E3 = Areas of medium ambient brightness, generally being urban residential areas. E4 = Areas of high ambient brightness, which would include dense urban areas with mixed residential and commercial use with high levels of nighttime activity. C. Service station canopies and parking garages. 1. All luminaries mounted on or recessed into the lower surface or service station canopies and parking structures shall be fully shielded and utilize flat lenses. 2. The total light output of luminaries mounted on the lower surface, or recessed into the lower surface of the canopy, and any lighting within signage or illuminated panels over the pumps, shall not exceed fifty (50) foot-candles. The total light output of other illuminated areas of a service station shall not exceed fifteen (15) foot-candles. 3. Illuminance levels for the interior of parking structures, where interior lighting is visible from outside the structure, shall conform to IESNA recommendation RP-20. 4. Lights shall not be mounted on the top or sides of a canopy, and the sides of the canopy shall not be illuminated. D. Security lighting. 1. Security lighting shall be directed towards the targeted area and shall not be on poles taller than twenty (20) feet. 2. Security lighting shall be maintained in such a manner as to prevent glare and lighting into properties of others or into a public right-of-way, and the system also shall be designed and maintained so that lights are not activated by activity off of the subject property. E. Pedestrian path lighting. Lighting posts for pedestrian path lighting shall not exceed sixteen (16) feet in height from finished grade. F. Architectural accent lighting. 1. Fixtures used to accent architectural features, materials, colors, style of buildings, landscaping, or art shall be located, aimed and shielded so that light is directed only on those features. Such fixtures shall be aimed or shielded to minimize light spill into the dark night sky in conformance with the luminaire standards. 2. Lighting fixtures shall not generate glare, or direct light beyond the fa~ade onto a neighboring property, streets or into the night sky. G. Parking areas (including decks). 1. All lighting fixtures servicing parking areas shall be directed downward and not towards buildings or other areas. 2. Parking areas shall be illuminated to a minimum illumination level of0.4 foot-candles at grade level, and the ratio of the average illumination to the minimum illumination shall not exceed 4:1. 3. Light poles used in parking areas with one hundred (100) parking spaces or less shall not exceed twenty (20) feet in height, including the base. Light poles used in parking lots with more than one hundred (100) parking spaces shall not exceed thirty (30) feet in height, including the base. H. Temporary lighting permits. The city manager may grant permits for temporary lighting if the total output from the luminaries does not exceed fifty (50) foot-candles, subject to the following regulations: 1. The lighting shall not remain for more than thirty (30) days, except that permits for a major construction project may extend to completion. 2. The lighting shall be designed in such a manner as to minimize light trespass and glare. 3. Temporary recreational lighting allowed by permit shall be extinguished by 10:30 p.m.