A. Purpose and intent.

1) This district provides development standards for a uniform landscape and urban design theme to enhance the gateway to downtown Ball Ground. The specific urban design, transportation and land use requirements set forth are an extension of the orderly growth guidelines developed in the City's Comprehensive Plan.

2) The incorporation of extensive buffering techniques seeks to assist in the preservation of such adjoining residential areas by providing a unique transition zone rather than traditional descending density theory.

3) The district is intended to generate quality new development along Ball Ground/ Canton Highway while promoting economic, cultural, open space and safety features to aid the public's general welfare. This orderly planning system is intended to attract commercial and mixed-use development and discourage strip commercial development, which is consistent with the comprehensive plan.

4) Basic precepts for the district include:

a) Respect, preservation and use of existing landforms, trees and other landscape themes.

b) Shielding of parking areas through the dispersion of parking, berms, diffused sight lines and landscaping.

c) Building with finished front, side and rear elevations.

d) Respect, preservation and use of vernacular architecture and its elements.

e) Creation of a pedestrian environment.

B. Use limitations and conditions.

1) General requirements.

a) All development plans, excluding those for a single home on an existing lot of record, must be drawn by a professional engineer and must be submitted to the City for review and approval before any work may commence.

2) Architectural requirements.

a) The mass and spatial relationships should emulate traditional villages and local character. New buildings shall feature design and materials consistent with those found in North Georgia from 1890 thru the 1930s and must be in keeping with the 2007 Master Plan. They shall be compatible in size, scale, mass and roof pitch, with buildings and architectural styles prevalent in the area. The City may require the applicant to involve the services of a certified architect to verify and ensure architectural integrity and materials. All designs are subject to review and approval by the Administrator.

b) All building facades, including those facing a roadway, shall be of architectural treatments of glass and brick in keeping with the traditional architecture of downtown Ball Ground. Buildings may include additional combinations of stone, architectural block, Stucco and wood. Exterior building materials shall not be concrete masonry units, aluminum siding, vinyl siding or corrugated steel (exceptions: Mechanical penthouses and roof screens).

c) All ground level windows facing streets shall be clear, unpainted glass to allow view of store interiors and display windows. Mirrored glass with a reflection of greater than 20 percent and glass curtain walls shall be prohibited.

d) Areas of 150 linear feet or more of uninterrupted single finishes for all walls visible from the roadway or parking areas shall be broken up using trellises, arcades, false windows, archways, landscaping, storefront, or recessed panels reminiscent of window, door or colonnade openings.

e) Building design shall include a minimum one-foot deep cornice, extending along the entire front of the building and the sides of the building at least ten feet from the front of the building.

f) Building entry areas of single business buildings and the principal entry of a multi-business building shall be articulated and express greater architectural detail than other portions of the building.

g) Building design shall include a minimum three-foot high contrasting base (water table) extending along the entire front of the building.

h) To the extent any rear or side of any building is directly visible from any public street or residence, architectural treatment shall continue through the rear or side.

i) Windows shall be raised a minimum of three feet above the floor line. Window design will be in keeping with the architectural design of the building.

j) No more than 50 percent of a window pane may be covered by signage.

3) Site and landscape requirements.

a) All on-site utilities shall be located underground.

b) No more than 50 percent of the total on-premises parking area may be located within the front yard.

c) All free-standing signage must be monument style, with a distinctive base, middle and top. The sign shall be of compatible design with building architecture.

d) In addition to the requirements of the buffer ordinance, property frontages along all public rights-of-way shall feature an additional ten shrubs per 100 lineal feet of roadway.

e) Vehicular areas visible from Ball Ground/Canton Highway shall provide low screen walls with complimentary landscaping to help shield views.

f) Shared driveways, rear access and inter-parcel access are highly encouraged to limit curb cuts along the highway.

History

The history line the source prints at the end of the section.

(Ord. of 4-13-2023(2))