Ball Ground · Zoning Ordinance
Appendix A - ZONING / Division 105 - SUPPLEMENTARY DISTRICT REGULATIONS
Sec. 105.16. Development standards.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. The requirements regarding lot size, building site and building placement on the lot for each zone district shall be met as indicated in the charts of this section.
B. Flexibility of standards for historic preservation.
1) For those properties located within the boundaries of the official Ball Ground National Register Historic District that have existing, "contributing" historic structures on them, the requirements of the Development Standards Charts, except for those involving density, may be given flexibility in order to save and/or protect the historic, "contributing" structure and/or lot.
2) Staff may grant flexibility for these standards, but only after the applicant has properly and overwhelmingly demonstrated that the flexibility is necessary to protect and/or improve the historic structure and/or lot.
3) The applicant shall provide clear documentation by a registered/certified architect, registered/certified landscape architect, registered/certified historic preservationist, [and a] registered/certified engineer stating how development standard flexibility will accomplish the historic preservation.
4) Staff decisions can be appealed to the Board of Zoning Appeals or to the City Council.
C. Residential Development Standards Chart.
District Min.
Site Area (ac) Min. Lot Size Per Unit (sq ft) Max.
Density (units per ac) Min. Lot Width Per Unit (ft.)
Max.
Bldg.
Height (ft.)
Max Imperv.
Surface (%) Front Setback (Arterial) (ft.)
Front Setback (Other) (ft.)
Side Setback (ft.)
Rear Setback (ft.)
AG - 10 AC 0.1 250 45 20 100 100 100 100
R80 - 2 AC 0.5 150 35 30 40 40 40 40
R40 - 40,000 1.089 130 35 30 30 30 15 25 R30 - 30,000 1.452 100 35 30 30 25 10 25 R20 - 20,000 2.178 80 35 30 30 25 10 25 R15 - 15,000 2.904 75 35 30 30 204 10 20
RZL 5 4,356 6 40 35 50 30 204
103 20 RM41
- 2 AC6 6 1006 35 - 405 205 105 255
CC-C - - 10 - 50 - 0—20'
Build-to 0—20' Build-to
- -
CC-T1
- 4,356 10 35 35 75 20 10 10 10
- 1,150 10 20 40 601
* 305 155 105 District Min.
Site Area (ac) Min. Lot Size Per Unit (sq ft) Max.
Density (units per ac) Min. Lot Width Per Unit (ft.)
Max.
Bldg.
Height (ft.)
Max Imperv.
Surface (%) Front Setback (Arterial) (ft.)
Front Setback (Other) (ft.)
Side Setback (ft.)
Rear Setback (ft.)
CC-R - 6,000 7 40 35 60 30 15 10 10
TND2
- 7,260 6 35 35 60 30 10-25 Build-to 10 25 2 1,150 10 20 40 - 305 20—25 Buildto5 105 255 2 2 AC6 10 1006 40 - 405 25—30 Buildto5 155 255
1. CC-T:
• 1st Row: Single-family, detached.
• 2nd Row: Duplexes, triplexes, quadplexes and townhomes (*lot coverage applies to development and not individual residential lots).
2. TND:
• 1st Row: Single-family, detached.
• 2nd Row: Duplexes, triplexes, quadplexes and townhomes.
• 3rd Row: Multi-family apartment buildings.
3. RZL:
• The side setback must be allocated to one side.
4. R15 and RZL:
• The front setback may be reduced to ten feet if homes have rear entry garages.
5. RM4, CC-C, CC-T and TND:
• Setbacks are not required between units internal to a common development of attached housing. Setbacks shall apply to the exterior boundaries of these developments when abutting adjacent, unrelated properties and rights-of-way.
6. TND:
• The minimum lot size and width for an attached residential building in RM4 and TND zoning districts applies to the overall development and not an individual dwelling unit.
Note 1: Regardless of height, no building may be taller than three stories.
Note 2: For properties with abutting driveway access easements, building setback lines shall be measured from the edge of the easement line inward to the property; or inward from the property line; or inward from the edge of [the] roadway, whichever distance is greatest.
D. Commercial, Industrial and Mixed Use Development Standards Chart.
District Min. Site Area (sq. ft.)
Min. Lot Width (ft.)
Max Bldg.
Height (ft.)
Max Impervious Surface (%) Front Setback (Arterial) (ft.)
Front Setback (Other) (ft.)
Side Setback (ft.)
Rear Setback (ft.)
CC-T 15,000 50 40 60* 20-30'
Build-to 15 10 15
CC-C - - 50 - 0-20'
Build-to 0-20' Build-to
- -
TND 2 AC 100 50 - 50 15-30'
Build-to 15 25 NC 10,000 50 35 50 35 15 15 25 GC 20,000 75 40 75 35 20 15 30
BGH 20,000 75 40 75 35 20 15 30
LI 20,000 100 75 75 35 25 25 40
HI 5 AC 250 75 75 100 100 100 100
* Lot coverage applies to development and not individual residential lots.
Note 1: For properties with abutting driveway access easements, building setback lines shall be measured from the edge of the easement line inward to the property; or inward from the property line; or inward from the edge of [the] roadway, whichever distance is greatest.
History
(Ord. of 4-13-2023(3))
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.