All uses allowed in the underlying zoning districts are permitted in the groundwater recharge area protection district. The following are additional requirements for specific uses: a. All above-ground chemical or petroleum storage tanks, having a minimum volume of 660 gallons, shall meet the requirements of US EPA rules for oil pollution prevention, 40 CFR 112.1, including a secondary containment for 110 percent of the volume of such tanks or 110 percent of the volume of the largest tank in a cluster of tanks. Such tanks used for agricultural purposes are exempt, provided they comply with all federal requirements. Enforcement of the Standard Fire Prevention Code by a local government means that the government already has a regulation in place that meet this criterion. b. New dwellings served by septic tank and absorption field systems shall be on lots having the following minimum size as identified in Table 1: (1) One hundred fifty percent of the subdivision minimum lot size of Table 1 if the lot is within a high pollution susceptibility area; (2) One hundred twenty-five percent of the subdivision minimum lot size of Table 1 if the lot is within a medium pollution susceptibility area; (3) One hundred ten percent of the subdivision minimum lot size of Table 1 if the lot is within a low pollution susceptibility area. c. New mobile home parks served by septic tanks and absorption field systems shall be on lots having the following minimum size as identified in Table 2: (1) One hundred fifty percent of the subdivision minimum lot size of Table 2 if the lot is within a high pollution susceptibility area; (2) One hundred twenty-five percent of the subdivision minimum lot size of Table 2 if the lot is within a medium pollution susceptibility area; (3) One hundred ten percent of the subdivision minimum lot size of Table 2 if the lot is within a low pollution susceptibility area. d. All multifamily development located within a high pollution susceptibility groundwater recharge area shall be required to have the following minimum lot sizes: where individual on-site sewage systems are installed in conjunction with public water systems the minimum lot size for a multi-family structure shall be 10,890 square feet per unit; where individual on-site sewage systems are installed in conjunction with an individual water system the minimum lot size shall be 21,780 square feet per unit. All multi-family developments shall be approved by the Banks County Board of Health. If there are conflicts between provisions of these regulations, the stricter shall apply. e. All new wastewater treatment basins shall have an impermeable liner in areas having high pollution susceptibility except for the construction of mining settling basins. f. All new agricultural waste impoundment sites shall be lined if they are within: A high pollution susceptibility area; A medium pollution susceptibility area and exceed 15 acre-feet in size; and A low pollution susceptibility area and exceed 50 acre-feet in size. As a minimum, the liner shall be constructed of compacted clay having a thickness of one foot and a vertical hydraulic conductivity of less than 5×10-7 cm/sec or other criteria established by the U.S. Soil Conservation Service.