--- title: Banks County Zoning Ordinance, SECTION 507. UNLIMITED AREA BUILDINGS collection: local-codes id: local-code:banks-county/zoning/507 cite_as: Banks County, Ga., Zoning Ordinance ยง 507 canonical_url: https://georgiacommons.org/code/local/banks-county/zoning/507 md_url: https://georgiacommons.org/code/local/banks-county/zoning/507.md text_url: https://georgiacommons.org/code/local/banks-county/zoning/507/text source_url: https://library.municode.com/ga/banks_county/codes/code_of_ordinances date: 2024-11-12 status: active jurisdiction: county:banks jurisdiction_name: Banks County county_fips: "13011" corpus_version: local-codes-banks-county-6adf4de56829 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/banks-county/zoning/~appendix-a/~chapter-5.md previous: https://georgiacommons.org/code/local/banks-county/zoning/506.md next: https://georgiacommons.org/code/local/banks-county/zoning/508.md index: https://georgiacommons.org/code/local/banks-county.md branch: zoning edition: As published by Municode, current through 2024-11-12 edition_date_kind: current_through source_publisher: Municode version_id: local-code:banks-county/zoning/507@2024-11-12-98b77dab82 --- # Banks County Zoning Ordinance, SECTION 507. UNLIMITED AREA BUILDINGS > As published by Municode, current through 2024-11-12 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - ZONING / Chapter 5 - GENERAL BUILDING HEIGHTS AND AREAS 507.1 Unsprinklered, one-story. The area of a one-story, Group F-2 or S-2 building shall not be limited when the building is surrounded and adjoined by public ways or yards not less than 60 feet (18 288 mm) in width. 507.2 Sprinklered, one-story. The area of a one-story, Group A-4, B, F, M or S building shall not be limited when the building is provided with an automatic sprinkler system throughout in accordance with Section 903.3.1.1, and is surrounded and adjoined by public ways or yards not less than 60 feet (18 288 mm) in width. Exceptions: 1. Buildings and structures of Types I and II construction for rack storage facilities, which do not have access by the public shall not be limited in height provided that such buildings conform to the requirements of Section 507.1 and NFPA 231C. 2. The automatic sprinkler system shall not be required in areas occupied for indoor participant sports, such as tennis, skating, swimming and equestrian activities, in occupancies in Group A-4, provided that: 2.1. Exit doors directly to the outside are provided for occupants of the participant sports areas, and 2.2. The building is equipped with a fire alarm system with manual fire alarm boxes installed in accordance with Section 907. 507.3 Two-story. The area of a two-story, Group B, F, M or S building shall not be limited when the building is provided with an automatic sprinkler system in accordance with Section 903.3.1.1 throughout, and is surrounded and adjoined by public ways or yards not less than 60 feet (18 288 mm) in width. 507.4 Reduced open space. The permanent open space of 60 feet (18 288 mm) required in Sections 507.1, 507.2 and 507.3 shall be permitted to be reduced to not less than 40 feet (12 192 mm) provided the following requirements are met: 1. The reduced open space shall not be allowed for more than 75 percent of the perimeter of the building. 2. The exterior wall facing the reduced open space shall have a minimum fire-resistance rating of 3 hours. 3. Openings in the exterior wall, facing the reduced open space, shall have opening protectives with a fire-resistance rating of 3 hours. 507.5 High-hazard use groups. Groups H-2, H-3 and H-4 fire areas shall be permitted in unlimited area buildings having occupancies in Use Groups F and S, in accordance with the limitations of this section. Fire areas located at the perimeter of the unlimited area building shall not exceed 10 percent of the area of the building nor the area limitations specified in Table 503 as modified by Section 506.2, based upon the percentage of the perimeter of the fire area that fronts on a street or other unoccupied space. Other fire areas shall not exceed 25 percent of the area limitations specified in Table 503. Fire-resistance rating requirements of fire barrier assemblies shall be in accordance with Table 302.3.3. 507.6 Aircraft paint hangar. The area of a one-story, Group H-2 aircraft paint hangar shall not be limited where such aircraft paint hangar complies with the provisions of Section 412.4 and is entirely surrounded by public ways or yards not less in width than one and one-half times the height of the building. 507.7 Group E buildings. The area of a one-story Group E building of Type II, IIIA or IV construction shall not be limited when the following criteria are met: 1. Each classroom shall have not less than two means of egress, with one of the means of egress being a direct exit to the outside of the building complying with Section 1005. 2. The building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. 3. The building is surrounded and adjoined by public ways or yards not less than 60 feet (18 288 mm) in width. 507.8 Motion picture theaters. In buildings of Type I or II construction, the area of one-story motion picture theaters shall not be limited when the building is provided with an automatic sprinkler system throughout in accordance with Section 903.3.1.1 and is surrounded and adjoined by public ways or yards not less than 60 feet (18 288 mm) in width.