--- title: Barrow County Zoning Ordinance, Sec. 89-1318. Requirements for development plans collection: local-codes id: local-code:barrow-county/zoning/89-1318 cite_as: Barrow County, Ga., Zoning Ordinance § 89-1318 canonical_url: https://georgiacommons.org/code/local/barrow-county/zoning/89-1318 md_url: https://georgiacommons.org/code/local/barrow-county/zoning/89-1318.md text_url: https://georgiacommons.org/code/local/barrow-county/zoning/89-1318/text source_url: https://library.municode.com/ga/barrow_county/codes/code_of_ordinances date: 2026-11-23 status: active jurisdiction: county:barrow jurisdiction_name: Barrow County county_fips: "13013" corpus_version: local-codes-barrow-county-4325bd144603 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/barrow-county/zoning/~part-ii/~chapter-89/~article-xii.md previous: https://georgiacommons.org/code/local/barrow-county/zoning/89-1317.md next: https://georgiacommons.org/code/local/barrow-county/zoning/89-1319.md index: https://georgiacommons.org/code/local/barrow-county.md branch: zoning edition: As published by Municode, retrieved 2026-11-23 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:barrow-county/zoning/89-1318@2026-11-23-3d40415dd2 --- # Barrow County Zoning Ordinance, Sec. 89-1318. Requirements for development plans > As published by Municode, retrieved 2026-11-23 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 89 - UNIFIED DEVELOPMENT CODE / Article XII - PROCEDURES AND PERMITS (a) Generally. (1) Persons seeking to undertake land-disturbing activity (as defined in this Development Code) shall not commence or proceed until development plans are approved and a development permit is issued by the planning and community development department. The process for approval of a development permit is presented in the development permit section (section 89-1318), below. (2) The development plans for a project shall conform in all respects with the requirements of this Development Code, and shall include each of the plans in this section as appropriate to the project. These include: a. Erosion and sedimentation control plan; b. Grading plan; c. Floodplain management plan; d. Stormwater management plan; e. Street improvement plan; f. Street widening construction data; g. Landscaping, buffer and tree conservation plans; and h. Public utility plans. (3) Standard plans and specifications referred to in this section are the minimum acceptable standards. Additional information may be required by the county as needed for a complete understanding of the development proposed. (4) All development plans and supporting studies shall be prepared by or under the supervision of a professional engineer registered in the state, except that the landscaping, buffer and tree conservation plans are to be prepared by or under the supervision of a landscape architect registered in the state. (b) Erosion and sedimentation control plan. (1) Plans must be prepared to meet the erosion and sedimentation control requirements of the land development activities article of this Development Code. Conformance with the minimum requirements may be attained through the use of design criteria in the current issue of the �Manual for Erosion and Sediment Control in Georgia�; or through the use of alternate design criteria that conform to sound conservation and engineering practices. The erosion and sedimentation control plan shall consider the interrelationship of the soil types, geological and hydrological characteristics, topography, watershed, vegetation, proposed permanent structures including roadways, constructed waterways, sediment control and stormwater management facilities, local ordinances and state laws. (2) Data required for erosion and sedimentation control plan. a. Narrative or notes, and other information: Notes or narrative to be located on the erosion and sedimentation control plan in general notes or in erosion and sediment control notes. b. Description of existing land use at project site and description of proposed project. c. Name, address, and phone number of the property owner and the developer. d. Name and phone number of 24-hour local contact who is responsible for erosion and sediment controls. e. Size of project, or phase under construction, in acres. f. Activity schedule showing anticipated starting and completion dates for the project. Include the statement in bold letters that "the installation of erosion and sediment control measures shall occur prior to or concurrent with land-disturbing activities". g. Stormwater and sedimentation management systems storage capacity, hydrologic study, and calculations, including off-site drainage areas. h. Vegetative plan for all temporary and permanent vegetative practices, including species, planting dates, and seeding, fertilizer, lime and mulching rates. The vegetative plan should show options for year-round seeding. i. Detail drawings for all structural practices. Specifications may follow guidelines set forth in the �Manual for Erosion and Sediment Control in Georgia�. j. Maintenance statement to read as follows: "Erosion and sediment control measures will be maintained at all times. If full implementation of the approved plan does not provide for effective erosion and sediment control, additional erosion and sediment control measures shall be implemented to control or treat the sediment source". (3) Maps, drawings and supportive computations shall bear the signature/seal of a registered or certified professional in engineering, architecture, landscape architecture, land surveying or erosion and sediment control. After December 31, 2006, all persons involved in land development design, review, permitting, construction, monitoring, or inspection or any land-disturbing activity shall meet the education and training certification requirements as developed by the commission pursuant to O.C.G.A. § 12-7-20. The certified plans shall contain: a. Graphic scale and north point or arrow indicating magnetic north. b. Vicinity map showing location of project and existing streets. c. Boundary line survey. d. Delineation of disturbed areas within project boundary. e. Existing and planned contours, with contour lines drawn with an interval in accordance with the following: Map Scale Ground Slope Contour Interval, ft. 1 inch =100 ft. or larger scale Flat 0—2% Every 1 foot Rolling 2—8% Every 2 feet Steep 8% + Every 10 feet f. Spot elevations: 1. For sites smaller than one acre in size, show the direction of drainage and spot elevations at all breaks in grade and along drainage channels or swales at selected points not more than 100 feet apart. 2. For sites of one acre and larger with slopes of less than two percent, show contours at intervals of not more than two feet and spot elevations at all breaks in grade along drainage channels and swales at selected points not more than 100 feet apart. g. Adjacent areas and features such as streams, lakes, residential areas, etc. which might be affected should be indicated on the plan. h. The limits of the 100-year floodplain. i. Proposed structures or additions to existing structures and paved areas. j. The 25-foot horizontal stream buffer adjacent to state waters and the specified width in MRPA areas, or other stream buffer as required under the environmental protection article of this Development Code. k. The specified horizontal stream buffer along designated trout streams, where applicable. l. Location of erosion and sediment control measures using coding symbols from the �Manual for Erosion and Sediment Control in Georgia�, Chapter 6. (4) Maintenance of all soil erosion and sedimentation control practices, whether temporary or permanent, shall be at all times the responsibility of the property owner. (c) Grading plan. (1) Grading plans shall identify existing and proposed topographic contour lines at the interval required for erosion and sedimentation control plans, above. (2) Grading plans shall outline any area that is required to remain undisturbed, such as a natural buffer, tree protection area or greenway (see the buffers and tree conservation article and the environmental protection article of this Development Code) and shall identify and describe the protective fencing or staking to be placed surrounding such area. (3) If the property contains any area of special flood hazard (the 100-year floodplain), grading plans in and around the floodplain shall be designed in conformance to all requirements relating to flood damage prevention under the land development activities article of this Development Code. (d) Stormwater management plan. A stormwater management permit is required for all developments, except for those specifically exempted in this Development Code. (1) Submission of plan. a. Review and approval. In order to obtain a stormwater management permit, a stormwater management site plan showing the design of the development shall be provided to the department of engineering for review and approval. b. Effect on permits. A development permit, building permit or land disturbance permit shall not be issued without an approved stormwater management site plan. (2) General standards. All drainage facilities shall be included in a surface drainage plan and shall be so designed to serve the entire drainage area. No increase in peak discharge to existing streams or stormwater sewers shall be permitted unless calculations are submitted and approved showing that such increase will not adversely affect upstream or downstream conditions. (3) Requirements for proposed improvements. The location and size of all proposed stormwater improvements shall be designed in accordance with and meet all standards relating to stormwater management of the current edition of the "Georgia Stormwater Management Manual." (4) Stormwater management site plan requirements. The stormwater management plan shall include the information listed below, as more specifically detailed in the current edition of the "Georgia Stormwater Management Manual." a. Existing conditions hydrologic analysis. 1. A topographic map of existing site conditions (minimum two-foot contour interval) with the basin boundaries indicated. 2. Acreage, soil types and land cover of areas for each subbasin affected by the project. 3. All perennial and intermittent streams and other surface water features. 4. All existing stormwater conveyances and structural control facilities. 5. Direction of flow and exits from the site. 6. Analysis of runoff provided by off-site areas upstream of the project site. 7. Methodologies, assumptions, site parameters and supporting design calculations used in analyzing the existing conditions site hydrology. a. Post-development hydrologic analysis. 1. A topographic map of developed site conditions (two-foot contour interval required) with the post-development basin boundaries indicated. 2. Total area of post-development impervious surfaces and other land cover areas for each sub-basin affected by the project. 3. Unified stormwater sizing criteria runoff calculations for water quality, channel protection, overbank flooding protection and extreme flood protection for each sub-basin. 4. Location and boundaries of proposed natural feature protection areas, such as natural buffers and tree protection areas (see the general development standards article of this Development Code), and primary and secondary conservation areas (see the resource conservation article of this Development Code). 5. Documentation and calculations for any applicable site design credits that are proposed to be utilized. 6. Methodologies, assumptions, site parameters and supporting design calculations used in analyzing the existing conditions site hydrology. b. Stormwater management system. 1. Drawing or sketch of the stormwater management system including the location of nonstructural site design features and the placement of existing and proposed structural stormwater controls. This drawing is to show design water surface elevations, storage volumes available from zero to maximum head, location of inlet and outlets, location of bypass and discharge systems, and all orifice/restrictor sizes. 2. Narrative describing that appropriate and effective structural stormwater controls have been selected. 3. Cross-section and profile drawings and design details for each of the structural stormwater controls in the system. This is to include supporting calculations showing that the facility is designed according to the applicable design criteria. 4. Hydrologic and hydraulic analysis of the stormwater management system for all applicable design storms (including stage-storage or outlet rating curves, and inflow and outflow hydrographs). 5. Documentation and supporting calculations showing that the stormwater management system adequately meets the unified stormwater sizing criteria. 6. Drawings, design calculations and elevations for all existing and proposed stormwater conveyance elements including stormwater drains, pipes, culverts, catch basins, channels, swales and areas of overland flow. c. Downstream analysis. Supporting calculations for a downstream peak flow analysis using the ten-percent rule necessary to show safe passage of postdevelopment design flows downstream. d. Operations and maintenance plan. Description of maintenance tasks, responsible parties for maintenance, funding, access and safety issues. e. Evidence of acquisition of applicable local and non-local permits. Such evidence shall include a copy of the Notice of Intent (NOI) form submitted to DNR under General Permit No. GAR100000 (relating to authorization under NPDES for stormwater discharges associated with construction activity). f. Waiver requests (if any). Waivers from the provisions of the current edition of the "Georgia Stormwater Management Manual" will be considered by the public works department on a case-by-case basis. Waivers may be granted only when a requirement is shown to be impractical or having no benefit on adequate stormwater management of the site, or for an alternative approach that will have greater benefit and practicality than that otherwise required. (e) Street improvement plan. (1) Plans must include centerline profiles and typical street sections of all proposed streets. Profiles shall be drawn on standard plan and profile sheet with plan section showing street layout, pavement and right-of-way width, curvature, and required drainage facilities. Typical street sections shall be provided for street widenings. (2) Where sanitary or storm sewers are to be installed within a street, the grade, size, location and bedding class of pipe, location and invert elevation of manholes shall be indicated on the road profile. (3) Centerline profile covering roadways that are extensions of existing roadways shall include: elevations at 50-foot intervals for such distance as may be adequate to provide continuity consistent with the standards required by these regulations for street improvements, but not less than 200 feet. (4) All elevations shall be coordinated and tied into U.S. Coast and Geodetic Survey or department of transportation benchmarks where feasible, or into reference monuments established by the Federal Emergency Management Agency. (5) A street striping and signage plan, showing improvements in accordance with the "Manual on Uniform Traffic Control Devices", latest edition as published by the Federal Highway Administration, shall be prepared for any street newly constructed or widened to four or more lanes. (6) Profile covering roadways that are extensions of existing roadways shall include: elevations at 50-foot intervals for such distance as may be adequate to provide continuity consistent with the standards required by these regulations for street improvements, but not less than 200 feet. (f) Landscaping, buffer and tree conservation plans. All proposed site landscaping and buffers as required by this Development Code for parking lot landscape areas, trees and street-side screening; in buffers; and trees to be retained or planted as required by the tree conservation provisions of this Development Code, shall be illustrated on plans as described in this subsection. The plans may be consolidated as one plan if the information can be clearly shown. (1) Site landscaping plan. a. Scale at one inch = 20 feet to 50 feet, as needed to clearly show illustrate the proposed plantings. Multiple sheets keyed to an index sheet may be used. b. Caption: 1. The name of the development and its acreage (or square footage if less than an acre). 2. Name, address, telephone and fax numbers of the property owner and subdivider or developer. 3. Name, address, telephone and fax numbers of the applicant. 4. Name, address, telephone and fax numbers of the individual or company responsible for the design. The name, registration number and seal of the professional under whom the plan was prepared shall be stamped on the plan and signed. 5. Date of survey, north point and graphic scale, source of datum, date of plan drawing, and revision dates, as appropriate. c. The location and size of all underground or aboveground utilities on the site, including the limits of any public or private utility easements and stormwater detention areas. d. The location of all existing and proposed parking areas, sidewalks and other paved or impervious surfaces. e. The outline of all existing and proposed buildings and structures. f. The boundaries of all natural buffers, greenways and other areas required to remain undisturbed. g. The boundaries of each required landscape strip. h. A planting plan showing the location, size and common name of proposed plant materials. i. The location, size and common name of all existing plant materials to be retained that contribute to meeting the minimum requirements of this Development Code for landscape strips or parking lot landscaping. (2) Buffer plan. A buffer plan shall be prepared for any natural or structural buffer required in accordance with the specifications and standards contained in this Development Code. The buffer plan shall show: a. Caption, as required under subsection (f)(1)b. for site landscaping plans. b. The boundaries of each required buffer area. c. The location and size of all underground or aboveground utilities on the site, including the limits of any public or private utility easements and stormwater detention areas. d. For each natural buffer, the plan must show: 1. Methods to be employed to protect the critical root zones of the trees in the buffer from disturbance during construction, including fencing details, erosion control, signage, etc., consistent with the protection of existing trees section of the buffers and tree conservation article of this Development Code. 2. Proposed supplemental plantings required to maintain the opaque visual screen required. e. For each structural buffer, the plan must show: 1. All grading and construction details for earthen berms, walls and fences that are proposed as part of the visual screen. 2. A planting plan showing the location, size and type of proposed plant materials. 3. The location, size and common name of all existing plant materials to be retained that contribute to meeting the minimum requirements of this Development Code for buffers. 4. Typical cross-sections of the buffer illustrating the improvements proposed and typical location of vegetation. At least one cross-section shall be provided for each buffer. (3) Landscaping plan. The landscaping plan shall be submitted to the Planning and Community Development Department prior to any grading, bulldozing, or other removal of existing vegetation that may affect the health of existing tree coverage. a. Landscaping plan; preparation. 1. The landscaping plan shall be provided for any development in accordance with Article VIII Division 3 and shall be related to the site plan for the project. 2. For subdivisions, the landscaping plan shall be drawn on a copy of the preliminary subdivision plat, to which the information required by this subsection will be added. b. The landscaping plan shall meet all requirements of article VIII division 3 and include the following basics: 1. Drawings at scale at one inch = 20 feet to 50 feet, as needed to clearly illustrate the proposed plantings. Multiple sheets keyed to an index sheet may be used. 2. Caption, as required under section 89-1318 (f)(1)b. for site landscaping plans. 3. The location and size of all underground or aboveground utilities on the site, including the limits of any public or private utility easements and stormwater detention areas. Off-site easements that may be affected by tree plantings must also be shown. 4. The location of all existing and proposed parking areas, sidewalks and other paved or impervious surfaces. 5. The outline of all existing and proposed buildings and structures. 6. The boundaries of all natural buffers, greenways and other areas required to remain undisturbed. 7. The boundaries of each required landscape strip. 8. Identification of all trees that will be retained upon the site. 9. Location of tree protection area fencing. 10. Location and species of trees and other landscaping to be planted. 11. Irrigation. i. The landscaping plan is to include a note indicating the type of irrigation to be used. If hand watering is the type to be used, the plan must show the location of water faucets or quick couplers that will be used for this purpose. ii. If an irrigation system is provided, a separate irrigation plan is to be submitted showing the location of lines and heads, the spray radius for each head, all valves (control, shut off, drainage, etc.), timer and rain sensor location. The name and telephone number of a responsible 24-hour emergency contact shall be prominently displayed on the plan. 12. During-construction activities: i. Methods to be employed to protect the critical root zones of the trees in the buffer from disturbance during construction, including fencing details, erosion control, signage, etc., consistent with article VIII division 3 of this Development Code. ii. Staging areas for parking, materials storage, concrete washout, and debris burn and tub grinding. 13. Additional information. Additional information that the planning and community development director may require to provide a full understanding of conditions on the site and the elements of the proposed tree conservation plan or during-construction activities. 14. Notes. Each landscaping plan shall include notes clearly printed on each plan sheet, as shown in Figure 12.8. (g) Public utility plans. (1) Domestic water supply plan. If connection to a public water system is proposed or required, the domestic water supply plan shall depict all water system improvements, water mains, fire hydrants, valves and other appurtenances, and other information as may be required by the providing water jurisdiction. (2) Sewage disposal plan. a. If a connection to a public system is proposed, sewage disposal plans are to include: Sanitary sewerage plans, including profiles of all mains and outfalls, lift station and force main details, typical manhole construction details, and other information as may be required by the providing sanitary sewer jurisdiction. b. For projects approved to be served by on-site sewage disposal systems, location of septic tank, extent of drain field and attendant structures, location and results of percolation tests, and other information shall be shown as required by the county health department. (Ord. of 10-13-2020) Figure 12.8 Tree Conservation Plan Notes