Bethlehem · Zoning Ordinance
Chapter 89 - UNIFIED DEVELOPMENT CODE / Article III - RESTRICTIONS ON PARTICULAR USES / Division 1 - RESTRICTIONS THAT APPLY IN GENERAL
Sec. 89-130. Standards for pre-owned manufactured homes.
About this text
- As posted on the city's website, retrieved 2026-11-11
These standards are applicable to any pre-owned manufactured home that is proposed to be moved into or relocated within the town. Mobile homes, which are defined as manufactured homes that do not conform to the Federal Manufactured Housing Construction and Safety Standards Act (the HUD Code), are not allowed to be moved into or relocated within the town.
(a) Pre-owned manufactured home; defined. A pre-owned manufactured home is a manufactured home, as defined in this Development Code, which has been placed, used or occupied as a residence subsequent to its original purchase as a new unit from a manufacturer or dealer.
(b) Required certification. All pre-owned manufactured homes moved into or relocated within the Town of Bethlehem must bear an approval seal (label) of either HUD or the Georgia Department of Community Affairs and shall not have been altered in such a way that the home no longer meets the HUD code.
(c) Reserved.
(d) Required inspection. Any pre-owned manufactured home being moved into or relocated within the town must pass inspection by a qualified HUD-certified inspector acceptable to the Town Council.
(1) This inspection will cover, but not be limited to:
a. Sanitary facilities.
1. Every plumbing fixture, water, and waste pipe shall be in a sanitary working condition free from leaks or obstructions.
2. Both cold and hot water must be supplied.
3. Water heating facilities must be in safe working condition.
b. Exterior condition.
1. Every habitable room shall have at least one window that can be opened facing directly to the outdoors.
2. The exterior of the home shall be free of loose or rotting boards or timbers and any other conditions that might admit rain or moister to the interior portions of the walls or to the occupied spaces.
3. The exterior siding shall be free of rot and rust and must be uniform in appearance.
4. Roofs shall be structurally sound and have no obvious defects that might admit rain or cause moisture to collect on the interior portion of the home.
c. Safety of operating systems(electrical, heating, etc.), including:
1. Heating facilities must operate in a safe working condition. Where a central heating system is not provided, each manufactured home shall be provided with facilities whereby a heating appliance may be connected.
2. Unvented fuel burning heaters shall be prohibited except for gas heaters listed for unvented use and the total input rating of the unvented heaters is less than 30 BTU per house per cubic foot of room content.
3. Unvented fuel burning heaters shall be prohibited in bedrooms.
4. Distribution panels shall be in compliance with the approved listing, complete with required breakers or fuses, with all unused openings covered with blank covers approved and listed for that purpose. Connections shall be checked for tightness. Panels shall be accessible.
5. Electrical systems (switches, receptacles, fixtures, etc.) shall be properly installed, wired and shall be in working condition. The home shall be subjected to an electrical continuity test(s) to assure that all metallic parts are properly bonded.
d. The presence of operable smoke detectors.
e. Interior condition.
1. Every floor, interior wall and ceiling shall be in sound condition.
2. Doors and windowsshall be operable, watertight and in good working condition.
3. The floorsystem shall be in sound condition and free of warping, holes, extensive water damage or deterioration.
f. Timing of inspection.
1. For a manufactured home to be relocated within the town, the inspection shall be conducted prior to moving the home from the original site.
2. For a manufactured home being moved into the town, either:
i. The inspection shall be conducted prior to moving the home from the original site; or ii. With the owner's written approval and acceptance of all liability, the inspection may be conducted at the new home site prior to connecting the manufactured home to a water supply, to a sanitary waste disposal system, and to permanent power.
Read this code where it is posted (city website) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.