(a) Every property upon which a principal building or use will be located shall meet or exceed the requirements shown on Table 4.1 for the zoning district in which the lot is situated.
(b) Maximum density.
(1) The total number of dwelling units in a residential subdivision or development shall not exceed the gross area of the subdivision or development property multiplied by the maximum density shown on Table
4.1. Residential densities are shown on the table as the number of dwelling units per acre.
(2) The maximum nonresidential density figures shown on Table 4.1 are used to determine the amount of gross floor area for nonresidential uses that can be constructed on a lot. Maximum floor area is determined by multiplying the floor area ratio (FAR) times the area of the lot in square feet. For instance, a one-acre lot at 0.5 FAR could accommodate 21,780 square feet of floor area (43,560 square feet of lot area × 0.5 FAR).
(3) Minimum lot width. Each minimum lot width shown on Table 4.1 shall be achieved at the minimum front setback line for a principal building on the lot, measured as described under the definition of "lot width".
For a lot having the majority of its frontage on a cul-de-sac, the minimum lot width shall be achieved at the minimum required front setback line or at a line parallel to said setback line at no more than twice the minimum front setback distance from the street.
(4) Authority of health department. Nothing contained in this article shall be construed as preventing the county health department, after study of the conditions existing in a proposed subdivision, from requiring that all or any portion of the area of such subdivision shall not be built upon or that the minimum lot sizes set forth in this Development Code are inadequate and must be increased to ensure the protection of the public health.
Table 4.1: Density, Lot Area, Width, Setbacks and Building Heights by Zoning District District Use Well and Septic
Tank Public Infrastructure Min.
Lot Width (feet) Building Setback (feet)***** Max.
Building Height (feet) Max.
Density Min.
Lot Size Max.
Density Min.
Lot Size Front Side Rear AG All uses 1 du/5 acres 5 acres 1 du/5 acres 5 acres 150 50 40 40 50 AR All uses 1 du/2 acres 2 acres 1 du/2 acres 2 acres 150 50 40 40 50 R-1 Single-Family Detached 1 du/1.3 acres 1.3 acres 1 du/acre 25,500 100 35 30 40 50 R-2 Single-Family Detached
N/A N/A 2.3
du/acre 10,000 75 30 30 40 45 Duplex N/A N/A 2.3 du/acre 10,000 75 30 30** 40 45 Townhouse Subdivision
N/A N/A 2.3
du/acre 2 acre Site 20 30*** 30** 40 45 R-3 Single-Family Detached
N/A N/A 2.9
du/acre 10,000 60 30 30 40 40 Duplex (per du) N/A N/A 2.9 du/acre 10,000 60 30 30** 40 40 Townhouse Subdivision
N/A N/A 8
du/acre 2 acre Site 20 30*** 30** 40 40 Townhouse Condominium or Apartment
N/A N/A 12
du/acre 2 acre Site 150 (Site) 30 30 40 50 MH Manufactured Home Subdivision
N/A N/A 3.5
du/acre 10,000 50 30 30 40 35 Manufactured Home Park
N/A N/A 5
du/acre 5 acre Site 100 (Site) 30 30 40 25 AC All uses 0.2
FAR
1 acre 0.25
FAR
1 acre 150 30 30 30 35 O-I All uses 0.2
FAR
40,000 0.25
FAR****
10,000 100 30 30 30 35 C-1 All uses 0.2
FAR
40,000 0.25
FAR
10,000 100 30 30 30 35 C-2 All uses 0.4
FAR
40,000 0.50
FAR
20,000 100 30 30 30 50 C-3 All uses 0.4
FAR
40,000 0.50
FAR
40,000 100 30 30 30 75 M-1 All uses 0.5
FAR
40,000 0.75
FAR
20,000 100 30 30 30 75 ** None required between attached principal buildings.
*** Rear vehicular access from an alley is required for all units; no parking allowed between the street and each unit.
**** A FAR of up to 0.5 and a building height of up to 50 feet may be allowed with special use approval.
***** The minimum principal building setback along an arterial road (including highways) shall be 100 feet from the right-of-way line. (See Section 89-404 (b)).