--- title: Bishop Zoning Ordinance, Section 1001. Plan and Design Standards for Off-Street Parking collection: local-codes id: local-code:bishop/zoning/1001 cite_as: Bishop, Ga., Zoning Ordinance § 1001 canonical_url: https://georgiacommons.org/code/local/bishop/zoning/1001 md_url: https://georgiacommons.org/code/local/bishop/zoning/1001.md text_url: https://georgiacommons.org/code/local/bishop/zoning/1001/text source_url: https://drive.google.com/file/d/1KFSgm5iE7xaBa4uKAPKkaIkeub17Rise/view?usp=sharing date: 2026-11-14 status: active jurisdiction: city:bishop jurisdiction_name: Bishop place_fips: "1308200" corpus_version: local-codes-bishop-a62d63d73e8a publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/bishop/zoning/~article-xii.md previous: https://georgiacommons.org/code/local/bishop/zoning/1000.md next: https://georgiacommons.org/code/local/bishop/zoning/1002.md index: https://georgiacommons.org/code/local/bishop.md branch: zoning edition: As posted on the city's website, retrieved 2026-11-14 edition_date_kind: retrieved source_publisher: city website (Google Drive link) version_id: local-code:bishop/zoning/1001@2026-11-14-6f1ea35590 --- # Bishop Zoning Ordinance, Section 1001. Plan and Design Standards for Off-Street Parking > As posted on the city's website, retrieved 2026-11-14 > Read by OCR from a scanned page: a character, a name, or a number may be misread. Part of: Article XII - ZONING DISTRICT DESCRIPTIONS AND USE PROVISIONS The following specifications set forth the required plan and design standards for off-street parking in the Town of Bishop, Georgia: hs Required area for each parking space. Each automobile parking space shall not be less than nine (9) feet wide and nineteen (19) feet deep. Adequate interior driveways shall connect each parking space with a public right-of-way. A maximum of one foot six inches of the required nineteen feet may overhang a grassed area. This overhang cannot be over a sidewalk or right-of-way and must be arranged in such a way as to allow adequate front-to-front parking. Interior Driveways. a. Interior driveways when used with 90-degree-angle parking shall be not less than twenty-four (24) feet wide; when used with 60 degree-angle parking, not less than twelve (12) feet wide with one-way traffic; when used with parallel parking or where no parking exists, not less than ten (10) feet for one-way traffic and not less than twenty (20) feet for two-way traffic. Interior driveways that are not associated with designated automobile parking spaces shall be not less than 20 feet wide for two-way traffic, and 12 feet wide for one-way traffic. All driveway dimensions are measured from edge-of-pavement to edge-of-pavement, and do not include any curbs and gutters within the minimum widths required. Adequate fire apparatus access and circulation within each development shall conform to the requirements of the Oconee County Fire Marshall and Public Works Department, based on applicable AASHTO standards and requirements of the NFPA and International Fire Code. Improvements of Off-Street Parking Lots_. All off-street parking lots shall meet the following standards (except for single-family residential areas): a. They shall be graded to insure proper drainage, surfaced with asphalt at least two inches (2") thick installed on a four inch (4") crusher run stone base applied on a properly prepared subgrade; or surfaced with concrete, five inches (5") thick of 3500 psi concrete applied on a stabilized subgrade consisting of at least one hundred fifty pounds (150 Ibs.) of stone per square yard mixed in four inches (4") deep and compacted. If Oconee County standards are different, the more stringent standards shall apply. The surface shall be maintained in good condition free of weeds, dust, trash, and debris. b. If the off-street parking facilities are to be used at night, they shall be properly illuminated for the safety of pedestrians and vehicles and for policing. Illumination devices such as, but not limited to, flood or spot lights shall be so placed and so shielded as to prevent the rays or illumination there from being cast into neighboring dwellings and approaching vehicles. A lighting plan and details shall be submitted to the Planning Director showing light templates (lighting footprints) for the proposed fixtures for review and verification of compliance with this provision. c. If located adjacent to any residential or office zoning district or if located adjacent to a public street, the last ten (10) feet adjoining such district or street shall be planted with a buffer per paragraph e. below. d. A Landscape Planting and Maintenance Plan including provisions for watering, maintenance and replacements is to be submitted to the Planning Director and approved prior to the issuance of a building permit. Installation of plant materials shall have been completed or bonded prior to the issuance of a certificate of occupancy. If bonded, such plant materials shall be installed within 30 days of the bond date. é. For buffers adjacent to public streets or rights-of-way, plant materials shall consist of at least one tree for each twenty-five (25) linear feet.of buffer and an evergreen hedge 3' tall when planted. For purposes of this section, such tree may be any shade tree native to this region that has a single trunk and which will reach at least thirty five (35) feet in height and (35) thirty five feet in spread at maturity and which, when planted, is a minimum height of ten (10) feet. For planted buffers adjacent to residential and office use or zoning districts, the evergreen hedge height shall be a minimum of 6' at the time of planting. f. An average of at least one tree, as defined in Paragraph e. above, occupying a planting space of at least ninety (90) square feet each shall be furnished for each ten (10) cars on the interior and for each five (5) cars on the perimeter of the parking lot. The perimeter of the parking lot includes the outside perimeter and any parking spaces adjacent to a building. g. Each parking space shall be clearly demarcated by a painted stripe no less than three (3) inches wide running the length of each of the longer sides of the space or by curbing or by other acceptable method which clearly marks and delineates the parking space within the parking lot. h. For vehicular use areas which do not include designated automobile parking spaces such as mini storage warehouses, truck loading and unloading spaces, impoundment yards, and the driveways and turning areas associated therewith, the required shade tree planting shall be one shade tree as defined in paragraph e. above for each 1,500 sf of such areas. A planting area of ninety (90) square feet shall be provided for each shade tree and the trees shall be generally spaced in a uniform pattern to provide shade, screening and reduced storm water runoff. These shade trees shall be in addition to the buffer plantings required by this ordinance. 4. Location of Required Off-Street Parking Spaces on Other Property. If the required automobile off-street parking cannot be reasonably provided on the same lot with the principal use or building, such required spaces may be provided on other property lying not more than four hundred (400) feet from the main entrance to the principal use. In this situation, the applicant shall submit with his application for a building permit an instrument duly executed and acknowledged which accepts as a condition for the issuance of a building permit the permanent availability of such off-street parking spaces to serve his principal use. 3. Sharing of Required Off-Street Parking Spaces. One-half of the off-street parking spaces required by a use whose peak attendance will be at night may be shared with a use that will be closed at night or on Sunday. 6. Exemptions to off-street parking requirements for incidental, occasional or temporary Uses. In A-1, agricultural zones, the Mayor and Council or the Planning Commission, acting as Council's designee, may grant exemption from certain requirements of this article for buildings or uses which are only subject to incidental, occasional or temporary parking needs, such as churches, cemeteries, recreation facilities, or other buildings and uses where parking is not required on a regular or daily basis. Said exemptions may: a. Allow substitution of gravel or similar hard surface material in lieu of asphalt or concrete; and b. waive the requirement for striping on the interior of the lot; and &. waive the requirements for lighting. Provided, however, that the minimum area and number of parking spaces and driveways required by this Ordinance shall be met and provided that said required parking area and drives shall be properly graded, surfaced and maintained so as to provide safe vehicular and pedestrian access and to prevent erosion, siltation and movement of mud, soil or debris and excessive or detrimental storm water runoff onto public or private lands. Prior to issuance of a waiver under this exemption, the applicant for building permit, subdivision plat or zoning amendment shall first submit for Planning Commission approval, the appropriate site development plan(s) required by the Zoning and/or Subdivision Ordinance. Said plan shall show the proposed layout, dimensions, grading, and access for the parking area for which exemption(s) are sought and shall indicate all requested exemptions and proposed improvements. ce Front yard setbacks as required in Article XIII do not apply to parking lots. Parking lots may be built to within five (5) feet of the right-of-way line in the front yard.