a. Required. For all subdivisions developed with five (5) or more dwelling units, a minimum of twenty (20) percent of units must meet the following “visitability” requirements. b. Visitability Requirements i. The home must have a minimum of one (1) no-step entrance into the home that leads from the driveway or public way to an entrance with a minimum 32-inch (width) clear opening to the home. . il. The home must have at least one bathroom on the same level as the no-step entrance that has a minimum 32-inch clear doorway and path to fixtures that allows ingress and egress by a wheelchair-bound individual. The wheelchair-bound individual must be able to open and shut the bathroom door. iii. The bathroom wall must be reinforced for grab-bars wood blocking in place to support grab bars as needed. iv. All exterior and interior doors shall be three feet in width and doors shall provide a minimum 32-inch clear opening. yi, When located on the same level as the no-step entrance, hallways and passageways shall be a minimum of 42 inches wide. Vi. Electrical wall outlets/receptacles shall be a minimum of fifteen (15) inches above finished floor when measure from the finished floor to center of the outlet. Vil. Wall switches controlling light fixtures and fans shall be a minimum of forty-eight (48) inches above finished floor when measured from finished floor to center of switch.