a. All catch basins and storm sewer structures shall be designed and constructed in compliance with Georgia D.O.T. Specifications and shall be Georgia D.O.T. Standard 1033D, 1034D, or 1019.

b. The use of a Standard 1019 shall be excluded from turnarounds and the low point of sag vertical curves draining more than 300 feet of gutter. Drainage calculations and design data are required for the use of a Standard 1019.

c. All drainage structures shall be constructed of reinforced precast concrete, 4 foot diameter or larger.

d. All 1033D and 1034D drainage structures shall require a reinforced precast “Round to Square” adapter for additional throat support.

e. All junction boxes shall include precast adapters and heavy duty traffic rated ring and covers. All junction boxes shall include approved steps, spaced 12 inches on center vertically, to allow safe access by maintenance personnel.

f. All storm sewer structures shall be reinforced precast or poured in place reinforced concrete. Masonry structures are not allowed unless authorized in writing by the City Engineer/ Public Works Director.

g. No length of pipe shall exceed 200 feet without intermediate structures.

h. In certain instances where rolled or “Hollywood” curb is utilized, the City Engineer/ Public Works Director may require the use of 1033F and 1034F catch basins.

i. All structures shall have poured inverts to minimize accumulation of water and sediment in the structure.

j. All structure covers shall be cast to read “City of Bogart Storm Sewer, Dump No Waste – Drains to Stream”.