(1) For access around buildings and for maintenance of building and lot improvements, an area generally at least 4 feet wide with a gradient away from the building no steeper than 1 in 10 (10% gradient), should be provided. (2) Where considered necessary by the inspection office, precautionary measures should be taken to stabilize the soil (e.g., retaining walls, sodding or planting). e. Suitable drainage structures, such as paved gutters, drain inlets and subsurface drain lines, should be installed, where necessary, to protect against dampness, flooding, erosion or other damage by surface water or ground water. (1) Drainage structures should be properly connected to adequate outlets that are protected by recorded permanent easements, if required. (2) Perimeter foundation drains are necessary on all houses with basements or potentially habitable living space below finish exterior earth grade or in other situations where water and/or soil conditions warrant their use. Outlets must not permit backflow into subsurface drains.