--- title: Bogart Zoning Ordinance, Sec. 1133.03. Building standards for streams without established base flood elevation and/or collection: local-codes id: local-code:bogart/zoning/1133.03 cite_as: Bogart, Ga., Zoning Ordinance ยง 1133.03 canonical_url: https://georgiacommons.org/code/local/bogart/zoning/1133.03 md_url: https://georgiacommons.org/code/local/bogart/zoning/1133.03.md text_url: https://georgiacommons.org/code/local/bogart/zoning/1133.03/text source_url: https://cityofbogart.com/assets/banners/11_stormwater----08.12.2024.pdf date: 2026-11-14 status: active jurisdiction: city:bogart jurisdiction_name: Bogart place_fips: "1309068" corpus_version: local-codes-bogart-4cae533395d4 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/bogart/zoning/~article-11/~division-iv.md previous: https://georgiacommons.org/code/local/bogart/zoning/1133.02.md next: https://georgiacommons.org/code/local/bogart/zoning/1133.04.md index: https://georgiacommons.org/code/local/bogart.md branch: zoning edition: As posted on the city's website, retrieved 2026-11-14 edition_date_kind: retrieved source_publisher: city website version_id: local-code:bogart/zoning/1133.03@2026-11-14-757c334a96 --- # Bogart Zoning Ordinance, Sec. 1133.03. Building standards for streams without established base flood elevation and/or > As posted on the city's website, retrieved 2026-11-14 Part of: Article 11 - Erosion Control and Stormwater Management / Division IV - FLOOD DAMAGE PREVENTION / 1133 - Provisions for flood hazard reduction. floodways (A zones). a. Located within the areas of special flood hazard, where streams exist but where no base flood elevation and floodway data has been provided or otherwise obtained from any official source, the following provisions apply: (1) When base flood elevation and floodway data has not been provided or cannot be obtained from any official source, then the Code Enforcement Director shall obtain, review and reasonably utilize any scientific or historic base flood elevation data available from a federal, state or other source, whether public or private, in order to administer the provisions of this Section. (2) If base flood elevation data can be determined under Sec. 1133.03.a, the provisions of Sec. 1133.02 shall apply. If such data are not available, then: (a) No encroachments, including fill material or structures, shall be located within an area equal to the width of the stream or 20 feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge. (b) In special flood hazard areas without base flood elevation data, new construction or substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than 3 feet above the highest adjacent grade at the building site. Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with the standards for elevated buildings, above. i. All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be elevated no less than three feet above the highest adjacent grade at the building site. b. Located within the areas of special flood hazard, where base flood data has been provided without floodways, the following provisions apply: (1) When floodway data has not been provided or cannot be obtained from any official source, then the Code Enforcement Director shall obtain, review and reasonably utilize any scientific or historic floodway data available from a federal, state or other source, whether public or private, in order to administer the provisions of this Section. (2) In addition to Sec. 1133.02, the following shall apply: (a) No encroachments, including fill material or structures, shall be located within an area equal to the width of the stream or twenty (20) feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge. (b) No encroachments, including fill material or structures, shall be located within the remaining area of special flood hazard area beyond the limits of the area delineated in 1133.03.b(2)(a) unless certification by a registered professional engineer is provided demonstrating that such encroachment, when combined with all other existing and anticipated development, shall not result in more than a one (1) foot increase in flood levels at any point in the community during the occurrence of the base flood discharge.