--- title: Bogart Zoning Ordinance, Sec. 1223.02. Aquifer protection site plan requirements collection: local-codes id: local-code:bogart/zoning/1223.02 cite_as: Bogart, Ga., Zoning Ordinance ยง 1223.02 canonical_url: https://georgiacommons.org/code/local/bogart/zoning/1223.02 md_url: https://georgiacommons.org/code/local/bogart/zoning/1223.02.md text_url: https://georgiacommons.org/code/local/bogart/zoning/1223.02/text source_url: https://cityofbogart.com/assets/banners/12_procedures---08.12.2024.pdf date: 2026-11-14 status: active jurisdiction: city:bogart jurisdiction_name: Bogart place_fips: "1309068" corpus_version: local-codes-bogart-4cae533395d4 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/bogart/zoning/~article-12/~division-iv.md previous: https://georgiacommons.org/code/local/bogart/zoning/1223.01.md next: https://georgiacommons.org/code/local/bogart/zoning/1223.03.md index: https://georgiacommons.org/code/local/bogart.md branch: zoning edition: As posted on the city's website, retrieved 2026-11-14 edition_date_kind: retrieved source_publisher: city website version_id: local-code:bogart/zoning/1223.02@2026-11-14-b82e9dd781 --- # Bogart Zoning Ordinance, Sec. 1223.02. Aquifer protection site plan requirements > As posted on the city's website, retrieved 2026-11-14 Part of: Article 12 - Procedures and Permits / Division IV - OTHER PERMITS Applications for a building permit or a development permit within the Aquifer Recharge Area shall include an aquifer protection site plan, with the exception of certain exempted activities identified in Sec. 1223.04. a. A map shall be drawn to a scale of 1" = 50' or other appropriate scale as determined by City of Bogart, showing all planned improvements including the width, depth, and length of all existing and proposed structures, roads, water courses, and drainage ways; water, wastewater, and storm water facilities; and utility installations. b. Location, dimensions and area of all impervious surfaces, both existing and proposed, on the site. c. The orientation and distance from the boundaries of the proposed site to the nearest bank of an affected perennial stream or water body. d. Location and detailed design of any spill and leak collection systems designed for the purpose of containing accidentally released hazardous or toxic materials. e. Location of all potable water supply wells within 200 feet of the site, and all proposed onsite wells. f. Calculations of the amount of cut and fill proposed and cross-sectional drawings showing existing and proposed grades in areas of fill or excavation. Elevations, horizontal scale, and vertical scale must be shown on cross-sectional drawings.