Bogart · Zoning Ordinance
Article 3 - Restrictions on Particular Uses / Division II - RESTRICTIONS ON CERTAIN PRINCIPAL USES
Sec. 329.06. Qualified manufactured home.
About this text
- As posted on the city's website, retrieved 2026-11-14
A manufactured home shall be considered a “qualified manufactured home” under the following conditions and provisions:
a. Ownership.
(1) The manufactured home must be permanently affixed on real property and one or more persons with an ownership interest in the manufactured home also must have an ownership interest in such real property.
(2) The owner of the manufactured home and the holders of all security interests therein must execute and file a Certificate of Permanent Location in accordance with State Law (O.C.G.A. 8-2-180 et seq.):
(a) With the Clerk of Superior Court for recordation in the real estate records of the County;
(b) A certified copy with the commissioner of motor vehicle safety; and
(c) A certified copy with the the City of Bogart Code Enforcement Director upon application for a permit to place the manufactured home on the property.
(3) The Certificate of Permanent Location shall be in a form prescribed by the commissioner of motor vehicle safety (or the Oconee County Tax Commissioner if so authorized) and shall include:
(a) The name and address of the owner of the home;
(b) The names and addresses of the holders of any security interest in and of any lien upon the home;
(c) The title number assigned to the home;
(d) A description of the real estate on which the home is or is to be located, including the name of the owner and a reference by deed book and page number to the chain of title of such real property; and
(e) Any other data the commissioner of motor vehicle safety prescribes.
(4) Upon filing a Certificate of Permanent Location, the certificate of title to the manufactured home issued under the Georgia Motor Vehicle Certificate of Title Act shall be surrendered by the owner to the commissioner of motor vehicle safety.
b. Compatibility standards.
(1) Orientation. If the manufactured home is located within 200 feet of a public street or road, it shall be oriented on the lot so that its main entrance door faces the street or road and the unit is approximately parallel to the street or road (within 10 degrees). “Parallel” shall be determined in relation to the street right-of-way line along a straight street section and in relation to a line tangent to the street rightof-way line along a curved street section.
(2) Moving apparatus. The running lights, moving hitch, wheels and axle shall be removed upon installation.
(3) Foundation. The manufactured home shall be properly installed on a poured concrete or permanent foundation.
(4) Exterior finish. The exterior siding of the manufactured home shall consist of horizontal wood or hardboard lap siding material, painted aluminum lap siding, or vinyl lap siding meeting the standards of the Vinyl Siding Institute.
(5) Skirting. The entire perimeter area between the bottom of the structure and the ground of each manufactured home shall be skirted or underpinned with acceptable materials, installed on a concrete footing, that completely encloses the perimeter of the undercarriage (except for proper ventilation and access openings). The skirting must be non-load bearing curtain walls and have no contact with the manufactured home for the purpose of structural support. Acceptable skirting materials must harmonize with the architectural style of the home, but are limited to the following:
(a) Brick or stone, or brick or stone veneer covering concrete block;
(b) Stucco finished concrete poured in place or concrete block; or
(c) Siding material that is the same as the exterior finish of the manufactured home.
(6) Roof pitch and materials. The manufactured home shall have a pitched roof with a slope of at least four feet in height for each 12 feet in width (4:12). Roof materials shall be wood shake, tile, or asphalt shingle material.
(7) Steps and landings. Permanent steps and landings shall be constructed at all exterior doors as necessary. A permanent, covered porch or landing measuring at least three feet in width and five feet in length shall be constructed at the front or main entrance to the manufactured home. A permanent porch or landing measuring at least three feet in width and three feet in length shall be constructed at all other entrances to the manufactured home.
(8) Additional architectural features. The manufactured home shall contain eaves with a minimum projection of six inches and at least two additional architectural features (as specified below) that will provide equal compatibility with surrounding residences and land uses, as approved by the Planning Director. Specified additional architectural features are:
(a) Recessed main entry or covered porch;
(b) Bay windows;
(c) Dormers;
(d) Window shutters;
(e) Attached garage;
(f) Gables; and
(g) Offsets on building face or roof (minimum 12 inches);
Read this code where it is posted (city website) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.