Bogart · Zoning Ordinance
Article 3 - Restrictions on Particular Uses / Division II - RESTRICTIONS ON CERTAIN PRINCIPAL USES / 343 - Utility substations and solar energy systems.
Sec. 343.07. Solar energy system, ground mounted.
About this text
- As posted on the city's website, retrieved 2026-11-14
a. Placement.
(1) A ground-mounted solar energy system shall not be located within the required front yard of a lot but shall be located in the side or rear yards only. Side and rear setbacks shall meet the setbacks for principal buildings for the district in which they are located.
(2) If located in a floodplain or an area of known localized flooding, all panels, electrical wiring, automatic transfer switches, inverters, etc. shall be located above the base flood elevation.
(3) Panels and ground mounts shall be installed per manufacturer's specifications.
b. Maximum area coverage.
For residential properties, a ground-mounted solar energy system shall not exceed 25% of the footprint of the principal building served. For non-residential properties, a solar energy system shall not exceed 50% of the footprint of the principal building served.
c. Height.
The maximum height of a ground-mounted solar energy system shall not exceed 20 feet in height above the ground.
d. Permitting.
A building permit is required for any ground-mounted solar energy system and for the installation of any thermal solar energy system.
Read this code where it is posted (city website) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.