Bogart · Zoning Ordinance
Article 6 - Parking and Loading / Division II - TRUCK LOADING / 612 - Improvement of truck loading areas.
Sec. 612.01. Surface and curbing of truck loading areas.
About this text
- As posted on the city's website, retrieved 2026-11-14
a. In areas used for loading docks, for the parking of commercial trucks and other commercial equipment, and for the storage of intermodal containers, the following surface is required:
(1) A 8-inch graded aggregate base, overlaid with a 2-inch Type B binder and a 1½- inch Type E asphaltic concrete wearing surface.; or,
(2) A 10-inch graded aggregate base, overlaid with a 12-inch course of 3,000 P.S.I.
concrete.
b. Curb and gutter meeting County or City specifications for public streets shall be installed around the periphery of every paved loading area containing 5 or more spaces, and extend along both sides of every access drive between the paved parking lot or loading area and the street or another parking lot or loading area, as applicable.
Read this code where it is posted (city website) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.