Sec. 1122. Finished grading.

About this text

  • As posted on the city's website, retrieved 2026-11-14

a. All unpaved lot areas, except those preserved in an appropriate natural condition, should be fine graded to provide smooth even surfaces conforming to the elevations specified below. All debris should be removed prior to fine grading.

b. Minimum protective slope. All walls and foundations of buildings and any water-supply well should be provided with protective slopes to assure immediate drainage and diversion of surface water away from these structures and off the site.

c. The finish grading should:

(1) Provide a minimum fall of 6 inches away from the structure in 10 feet, except as restricted by side lot lines or other major considerations, without regard to soil type or ground frost conditions. The horizontal length of such slopes may be reduced as necessary at building corners and side yards.

(2) Provide at least 6 inches in 25 feet (2% gradient) in all other unpaved areas, subject to ground frost, expansive soils, or collapsible soils, or at least 3 inches in 25 feet (1% gradient) in unpaved areas not subject to such conditions.

(3) If minimum slopes cannot be attained, paved gutters or other drainage structures may be installed as required by the inspection office.

(4) All unpaved areas should slope continuously at the above gradients to lower elevations off site, or to a drainage structure on the lot.

(5) Drainage swales or valleys formed by intersecting slopes should have adequate depth, width and longitudinal gradient to carry away the maximum predictable volume of storm water runoff based on a one hundred year return frequency. In no instance shall swales be positioned over sewage infiltration fields.

(a) Gradients of unpaved swales should not be less than required above for other unpaved areas.

(b) Surface erosion protection should be in place to prevent accumulation of water in critical drainage swales.

(6) Where catch basins or inlets are installed, other than at required basements areaways, finish grade elevations of adjoining areas should provide for emergency surface overflow so that, in event of failure of catch basins or inlets, buildings and window wells (or areaways) will be protected against flooding.

(7) Areaways for basement windows, entrances, and garage entrances should be provided with effective drainage facilities. Catchment areas should be as small as possible and must be protected from overflow of stormwater from adjacent areas.

(8) Roof drainage should discharge at least 5 feet away from building walls when expansive, collapsible or erodable soils are present.

d. Height and steepness of slopes and maximum gradients of unpayed drainage channels should be such as can be satisfactorily maintained without erosion or land slippage and should provide reasonable access to and around the structure.

Read this code where it is posted (city website) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:bogart/zoning/article-11-division-iii-1122@2026-11-14-8598e0e557

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Bogart Zoning Ordinance, Sec. 1122 (Article 11, Division III). Finished grading | Georgia Commons