3.2. Height and Area Measurements

About this text

  • As posted on the city's website, retrieved 2026-11-11

A. Building Height Building height is measured as the vertical distance measured from the average finished grade to the highest point of the coping of a low slope roof or the average height between the eaves and ridge of a pitched roof.

B. Building Height Exceptions Chimneys, spires, belfries, cupolas, domes, monuments, water towers, silos, chimneys, smokestacks, elevators, antennae, solar

panels, conveyors, flagpoles, masts, steeples, and wind turbines may not exceed the

maximum allowed height by more than 5 feet without securing a variance from the Zoning Board of Appeals (see Sec. 14.7). This

provision does not apply to telecommunications facilities (see ARTICLE 12).

C. Lot Coverage Lot coverage is measured as the percentage of the total area of a lot that is occupied by all principal and accessory structures (as

measured within the outside of the exterior walls of the ground floor), impervious parking areas, driveways, walkways, steps, terraces, uncovered patios and decks, swimming pools, and any similar features. The Planning

Director may establish rules for how partially pervious materials are counted toward lot coverage.

D. Sign Height Sign height is measured as the vertical distance from the adjacent ground elevation or the height of the crown of the adjacent street that the sign faces (whichever is higher) to the highest point of a sign, including the sign structure.

E. Sign Area

1. For wall signs, awning signs, and canopy signs and consisting of freestanding letters or logos, sign area is calculated as the total area of the smallest single rectangle,

circle, or square that fully encloses all the letters and images.

2. For signs on a background, the entire area of the background is calculated as sign

area, including any material or color forming the sign face and the background used to differentiate the sign from the

structure on which it is mounted. For ground signs, entrance signs, projecting signs, and sandwich board signs, sign area includes the face of the structure that the message is affixed to, not including any supports, base, apron, bracing, or other structural members.

3. The sign area for double-faced signs is computed as the area of the largest side.

F. Telecommunications Tower Height Telecommunications tower height is measured as the distance measured from the ground level existing prior to the beginning of any improvements to the highest point on the tower structure or appurtenance.

G. Lane or Median Width The width of vehicular lanes and medians is measured from edge of pavement.

Read this code where it is posted (city website (Revize)) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.