Braselton · Zoning Ordinance
Article 4 - DISTRICT-SPECIFIC STANDARDS
4.4. Residential Multi-Family District R-M
About this text
- As posted on the city's website, retrieved 2026-11-11
A. Purpose: This district is intended to provide moderate density residential and multifamily residential development, along with other ancillary uses compatible with a residential environment.
B. Lot Standards Lots Single-Family Dwelling with Alley Single-Family Dwelling with Garage in Rear Yard Townhouse, Stacked Duplex, or Live-Work All Other Dwellings 1 Minimum lot area 7,500 sq. ft. 8,000 sq. ft. 2,000 sq. ft. 10 acres
2. Minimum lot width 50 feet 60 feet 30 feet 100 feet
C. Building Placement Minimum Yards Single-Family Dwelling with Alley Single-Family Dwelling with Garage in Rear Yard Townhouse, Stacked Duplex, or Live-Work Multifamily & Townhouse Community
1. Front (arterial or collector street) 40 feet 40 feet 10 feet 40 feet
2. Front (local street) 10 feet 10 feet 10 feet 30 feet
3. Side (if driveway provided on that side of lot) n/a 20 feet n/a 25 feet
4. Side (all other instances) 5 feet 5 feet 10 feet a 25 feet
5. Side Street (principal dwelling) 10 feet 10 feet 10 feet 30 feet
6. Side Street (garage) 10 feet 35 feet 22 feet 30 feet
7. Rear (principal dwelling) 40 feet 25 feet 22 feet 25 feet
8. Rear (garage) 22 feet 5 feet 22 feet 25 feet
9. Rear (swimming pools and accessory buildings except garages) 10 feet 10 feet 10 feet 30 feet a 0 feet between dwellings For additional garage setbacks, see Sec. 6.7C.4
D. Other Regulations
1. Minimum floor area per dwelling:
a. 800 square feet per studio or one-bedroom dwelling for multifamily
b. 1,200 square feet per two- or more bedroom dwelling for multifamily
c. 1,800 square feet for one-story single-family dwellings
d. 2,200 square feet for multi-story single-family dwellings
2. Maximum height: 50 feet or 4 stories, whichever is less
3. Maximum density: 8 dwellings per gross acre
4. Minimum open space: 40% of gross site area (see Sec. 6.10)
5. For curb cut regulations, refer to Sec. 9.6.
6. For additional regulations, refer to Sec. 6.7.
A. Purpose The intent of this district is to provide larger scale, truly unique developments that other districts cannot accommodate. This district provides more flexibility with regard to design and allows for truly mixed-use developments rather than conventional residential
subdivisions with a commercial component.
B. Approved Plans
1. Each PUD district constitutes a separate zoning district. The land uses, concept
plan, development summary, and all other information, plats, plans, or architectural elevations approved by Town Council
establish the regulations and minimum requirements for the PUD district and constitute the zoning conditions that apply to the district, regardless of changes in property ownership.
2. Where approved uses conflict with the use table in Sec. 5.2, an approved plan by the Mayor and Council determines which uses
are permitted and prohibited.
C. Standards – Minimum Standards to be zoned Planned Unit Development (PUD) or for a
Major Revision to an existing PUD as noted.
1. Minimum district size for new PUDs: 20 acres
2. Minimum open space for new PUDs: 30% of site area
3. Maximum single-family detached dwelling density (new PUD or Major Revision): 4
dwellings per gross acre
4. Maximum townhouse or townhouse community density (new PUD or Major Revision): 8 dwellings per gross acre
5. Maximum multi-family dwelling density (new PUD or Major Revision): 8 dwellings per gross acre
6. Maximum building footprint for any building with a non-residential use (new PUD or Major Revision): 30,000 square
feet
7. For any accessory structure or swimming pool on the same lot as a single-family
detached dwelling, the minimum rear yard is the same as the minimum side yard for that same lot, as established in the
approved PUD legislation or approved plat.
D. Design Standards – The standards in paragraph D. shall be adhered to, unless in conflict with an approved site/concept plan and building elevations by Town Council
(approval either by new PUD zoning, PUD Major Revision, or other approval).
1. The number of non-multifamily dwellings with street-facing garages must not exceed 10% of all non-multifamily dwellings in any phase of the development or the overall
development. This requirement does not apply to garages that face the street but are located in a rear yard.
2. No vehicular parking area, including those used for vehicular sales, leasing, or
storage, may be located between any building and an adjacent street without an intervening building.
3. A continuous pedestrian network must be provided and must provide access to all
lots, buildings, and open spaces within the Planned Unit District.
4. All principal buildings must be oriented to face either an accessible open space or
the street of greatest intensity based on traffic volume, number of lanes, and/or
pedestrian activity, as determined by the Planning Director.
5. The primary pedestrian access to all individual ground level dwellings, tenant spaces, and other uses must either be
directly accessible and visible from the sidewalk adjacent to the primary façade or must provide a pedestrian connection with a minimum width of four feet to the
sidewalk.
6. Buildings may also be oriented to face a courtyard or mews. Individual uses may
have pedestrian entrances that open directly to a courtyard or mews.
7. All buildings except single-family detached dwellings and townhouse dwellings must
have a minimum floor-to-floor height of 9 feet on the ground floor.
8. No drive-through service window or associated element or driveway may be located between a building and any adjacent street.
9. Residential facades must have windows with transparent glass no less than 10
percent of the area of the façade as measured per floor.
10. Facades for all other uses must have storefronts and glazed with transparent
glass no less than 50 percent of the area of the ground floor façade and no less than 20 percent of the area of upper floor
facades. Ground floor fenestration is measured as a percentage of the area between two and eight feet above the average grade at the base of the façade.
11. Pedestrian entrances may be counted towards fenestration requirements.
E. Mix of Uses and Concurrency
1. Each Planned Unit Development district created after April 8, 2024 must include primary uses from at least two different use groups.
2. At least 25% of the total gross floor area within every Planned Unit Development
district must be exclusively devoted to residential uses and at least 25% of the total gross floor area within every Planned Unit Development district must be
exclusively devoted to non-residential uses.
3. For any Planned Unit Development district that includes multifamily residential, for both new and existing PUDs, at least 50% of the total gross ground floor area within that Planned Unit District must be
exclusively devoted to non-residential uses and must be the ground floor area of
conditioned air space (i.e. the ground floor area for improved outdoor space may not
be included).
4. Residential uses may not exceed 65% of the total gross ground floor area of all multifamily buildings for both new and
existing PUDs. The 35% (or more) of ground floor area devoted to nonresidential uses must be the ground floor area of conditioned air space (i.e. the
ground floor area for improved outdoor space may not be included).
5. No more than 10% of the total proposed number of dwellings in any Planned Unit
Development district may be issued a certificate of occupancy until such time as at least 10% of the total proposed gross floor area dedicated to non-residential
uses has been issued a certificate of completion.
6. No more than 25% of the total proposed number of dwellings in any Planned Unit
Development district may be issued a certificate of occupancy until such time as at least 25% of the total proposed gross floor area dedicated to non-residential
uses has been issued a certificate of completion.
7. No more than 50% of the total proposed number of dwellings in any Planned Unit
Development district may be issued a certificate of occupancy until such time as at least 50% of the total proposed gross floor area dedicated to non-residential
uses has been issued a certificate of completion.
8. No certificate(s) of occupancy or certificate(s) of completion may be issued for more than 10% of the total gross floor area dedicated to non-residential uses
until such time as a certificate of occupancy has been issued for at least 10% of the total proposed number of dwellings.
9. No certificate(s) of occupancy or certificate(s) of completion may be issued for more than 25% of the total gross floor area dedicated to non-residential uses
until such time as a certificate of occupancy has been issued for at least 25% of the total proposed number of dwellings.
10. No certificate(s) of occupancy or certificate(s) of completion may be issued for more than 50% of the total gross floor area dedicated to non-residential uses
until such time as a certificate of occupancy has been issued for at least 50% of the total proposed number of dwellings.
F. Revision to Approved PUD
1. Any proposal for a change or revision to an approved PUD project must first be reviewed by the Planning Director to determine if such a change or revision constitutes a minor revision or major revision. If the proposal meets the criteria set forth below in
paragraph (2) for a major revision, then the applicant must apply to amend the P.U.D.
and follow the procedures for a rezoning outlined in Article 14. Any proposed change to a PUD adopted without site plans shall be considered a major revision. If the proposal does not meet the criteria set forth below in paragraph (2), then the minor change or
minor revision may be authorized by agreement between the Planning Director and the Applicant.
2. The following criteria constitute a major change or major revision requiring an
application for amendment to a P.U.D.:
a.Will the proposal, in comparison to the currently approved P.U.D. zoning
application and/or the evidence presented during the zoning process, increase the potential for an adverse impact to adjacent properties, nearby properties, infrastructure, or traffic flow?
b.Will the proposal, in comparison to the currently approved P.U.D. zoning
application and/or the evidence presented during the zoning process, concentrate impacts differently to adjacent properties, nearby properties, infrastructure, or traffic flow?
c. Will the proposal, in comparison to the currently approved P.U.D. zoning
application and/or the evidence presented during the zoning process, change building/structure design, change architectural themes, change materials, changes square footages, or change building placement to an extent that the proposal does not reflect or resemble the original intent of the approved P.U.D.?
d. Will the proposal, in comparison to the currently approved P.U.D. zoning
application and/or the evidence presented during the zoning process, increase dwelling units, reduce minimum lot sizes, reduce minimum building setbacks, increase building height, or increase building square footages to an extent that it does not reflect or resemble the original intent of the approved P.U.D.?
e. Will the proposal, in comparison to the currently approved P.U.D. zoning
application and/or the evidence presented during the zoning process, alter the currently approved P.U.D. site plan to an extent that it does not reflect or resemble the original intent of the
approved P.U.D.?
f. Will the proposal increase, concentrate, or alter interior traffic within the project or exterior traffic flow around the project to an extent that the proposal does not
reflect or resemble the original intent of the approved P.U.D.?
g. Will the proposal require an amount of earthwork to an extent that the proposal does not reflect or resemble the original intent of the approved P.U.D.?
h. Will the proposal cause significant regulation conflict(s) with the approved P.U.D. that will result in a site plan that does not reflect or resemble the original intent of the approved P.U.D.?
Read this code where it is posted (city website (Revize)) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.