A. Purpose

1. Overall Purpose This district is intended to:

a. Enhance the quality and compatibility of development in Downtown Braselton.

b. Create a sense of place that is aesthetically appealing, walkable, and environmentally responsible.

c. Preserve historical structures.

d. Encourage appropriate economic development through infill development, redevelopment of underutilized property, and adaptive reuse of existing buildings.

e. Encourage a balance of uses for living, working, shopping, and playing that are accessible within a convenient walking distance.

f. Establish consistent and harmonious design standards for public improvements and private development to create a unified and distinctive visual quality for downtown.

2. Tier 1: Downtown Core (D-1) and Tier 3:

Downtown Mixed-Use (D-3) Purpose This subdistrict is intended to provide for the adaptive reuse, infill, and redevelopment of sites to form a central core of mixed uses for Downtown Braselton that conforms to consistent and harmonious design standards for public improvements and private property development so as to unify the distinctive visual quality of the Historic Downtown.

3. Tier 2: Downtown Edge (D-2) Purpose This subdistrict is intended to provide development guidelines for parcels developed with newer buildings adjacent to the downtown core and provides for a transition between the buildings in the inner core and surrounding areas.

B. Miscellaneous Provisions

1. Pre-Application Meeting Before submitting an application for a building permit, development permit, or preliminary plat approval, an applicant must schedule a pre-application meeting with the Planning Director to discuss the procedures, standards, and regulations required for approval. This requirement may be waived at the discretion of the Planning Director.

2. Escrow in Lieu of Improvements At the option of the Town, the developer may be required to pay funds into an escrow account in lieu of making public improvements required in this Development Code. Such escrow account must be established only for the purpose of coordination of such public improvements with a public improvement project that is part of an approved Capital Improvements Program. The amount of the escrow fund must be established by the Planning Director based on the projected construction cost of the improvements, based on the most recent edition of Georgia Department of Transportation “Item Means Summary” or other comparable standardized cost estimation procedure.

C. Building Types Within the Downtown Overlay District, building types are used to regulate the design of buildings. Each building type is described below and is determined by the Planning Director. Graphic depictions of building types are for façade illustrative purposes only.

These building types are for zoning purposes only, and not linked to the Building Code.

Freestanding parking decks are not considered to be a building type. Building types are allowed as shown in the table below.

Each building type is only permitted in a Tier in accordance with a use that per Section 5.2 is either permitted by right or granted through a special use approval by the Town Council.

Tier Building Type 1 2 3 Detached house X P X Carriage house X P X Cottage court X P X Duplex X P X Row house P P P Walk-up flat P P P Conventional multifamily X X X Commercial house X P X Storefront P P P Mixed use building P P P General building P P P Civic building P P P P = Permitted X = Prohibited

1. Detached house. A building type that accommodates one primary dwelling on an individual lot with yards on all sides. A detached house is not intended for nonresidential uses.

2. Carriage house. A small, self-contained accessory dwelling with no more than 800 gross square feet and no more than one bedroom, located on the same lot as a detached house, duplex, or row house but physically separated, for use as a complete, independent living facility, with provisions for cooking, sanitation, and sleeping.

3. Cottage court. A building type designed to accommodate 5 to 10 detached dwellings organized around a shared internal courtyard. Dwellings cannot be vertically mixed.

4. Duplex. A building type that accommodates two dwellings arranged either horizontally or vertically. Not intended for nonresidential uses.

5. Row house. A building type that accommodates 3 to 6 dwellings where each dwelling is separated by a common side wall. Dwellings may not be vertically mixed.

6. Walk-up flat. A building type that accommodates 3 to 8 dwellings vertically and horizontally integrated.

7. Conventional multifamily. A building type that accommodates 9 or more dwellings vertically and horizontally integrated.

8. Commercial house. Accommodates nonresidential uses in a building type that resembles a detached house. Not intended for residential uses.

9. Storefront. A single-story building type that typically accommodates single-use retail or commercial activity. Not intended for residential uses.

10. Mixed use building. A multi-story building type that typically accommodates ground floor retail, office, or commercial uses with upper-story residential or office uses. Not intended for ground floor dwellings.

11. General building. A multi-story building type that typically accommodates nonresidential uses such as industrial, hotel, or office uses on all stories.

12. Civic building. A building type that accommodates civic uses. Not intended for commercial, retail, office, or residential uses.

D. Development Standards

1. Lot Standards Lots Tier1 Tier 2 Tier 3

A. Minimum lot area none none none

B. Minimum lot width (row houses) see R-3 standards for townhouses see R-3 standards for townhouses see R-3 standards for townhouses

C. Minimum lot width (all other lots) none none none

2. Building Placement Tier Required Yards 1 2 3

A. Front (minimum) Detached house, cottage court, duplex, commercial house n/a 5 feet n/a Row house, walk-up flat, conventional multifamily 5 feet 5 feet 5 feet All other building types none none none

B. Front (maximum) Detached house, cottage court, duplex, commercial house n/a 60 feet n/a Row house, walk-up flat, conventional multifamily 10 feet 60 feet 10 feet All other building types 5 feet 60 feet 5 feet

C. Side (minimum) Detached house, cottage court, duplex, commercial house n/a 5 feet n/a Row house, walk-up flat, conventional multifamily 5 feet 5 feet 5 feet All other building types none none none

D. Side Street (minimum) Detached house, cottage court, duplex, commercial house n/a 5 feet n/a Row house, walk-up flat, conventional multifamily 5 feet 5 feet 5 feet All other building types none none none

E. Rear (minimum, all building types) none 5 feet none

3. Maximum Street-Facing Façade Length Building Type Max. Length per Building Detached house none Carriage house none Cottage court none Duplex none Row house none Walk-up flat none Conventional multifamily 200 feet Commercial house 100 feet Storefront 200 feet Mixed use building 200 feet General building 200 feet Civic building none

4. Other Standards Tier 1 Tier 2 Tier 3 Max. building height 65 feet or 5 stories, whichever is less 35 feet 65 feet or 5 stories, whichever is less Max. building footprint 10,000 sq. ft. 10,000 sq. ft. 10,000 sq. ft.

Max. lot coverage 80% of gross lot area 80% of gross lot area 80% of gross lot area Max. residential density 12 dwellings per

gross acre* 8 dwellings per gross acre 12 dwellings per gross acre* *There is no maximum residential density on lots of record legally existing as of April 9, 2024 that are less than 1 acre in size

5. Other Regulations

a. Street-facing garages are not permitted for single-family detached dwellings.

b. Minimum floor area per dwelling: none

c. No multifamily residential development or mixed-use development with multifamily dwellings may have more than 150 dwellings.

E. Design Standards

1. Dwellings with street-facing garages are prohibited. This prohibition does not apply to garages that face the street but are located in a rear yard.

2. At least 80% of all single-family, duplex, and row house dwellings within a development must face a public street, private street designed to public street standards, or open space. Alleys may not be used to satisfy this requirement. Cottage court dwellings that face a courtyard meeting the requirements of Sec. 6.10D are exempt from this requirement.

3. No more than 25% of required parking shall be permitted in any one yard situated between the principal building and a public street.

4. All principal buildings must be oriented to face either an accessible open space or the street of greatest intensity based on traffic volume, number of lanes, and/or pedestrian activity, as determined by the Planning Director.

5. The primary pedestrian access to all individual ground level or upper story dwellings, tenant spaces, and other uses must either be directly accessible and visible from the sidewalk adjacent to the façade facade or must provide a pedestrian connection with a minimum width of four feet to the sidewalk.

6. Buildings may also be oriented to face a courtyard or mews and individual uses may have pedestrian entrances that open directly to a courtyard or mews.

7. All buildings except single-family detached dwellings and row house dwellings must have a minimum floor-to-floor height of 9 feet on the ground floor.

8. No drive-through service window or associated element or driveway may be located between a building and any adjacent street.

9. Facades for residential uses must have windows with transparent glass no less than 10 percent of the façade of the facade as measured per floor.

10. Facades for all other uses must have storefronts and glazed with transparent glass no less than 50 percent of the area of the ground floor façade and no less than 20 percent of the area of upper floor facades. Ground floor fenestration is measured as a percentage of the area between two and eight feet above the average grade façade base of the facade.

11. Pedestrian entrances may be counted towards fenestration requirements.

F. Revision to Approved Concept Plan

1. Minor revision. The Planning Director is authorized to approve minor revisions to an approved concept plan in any D-1, D-2, or D-3 district that, in their opinion, are substantially in accord with approved plans and conditions. These changes may include minor adjustments to locations or dimensions of streets, rights-of-way, easements, buildings, parking, or infrastructure.

2. Major revision. Any requested revision to an approved concept plan in any D-1, D-2, or D-3 district that does not meet the requirements of a minor revision or which includes a change in proposed uses, increase in number of dwellings or square footage, decrease in lot size, or any other substantial change that is not consistent with the approved concept plan must follow the procedures in ARTICLE 14 for a rezoning.

Meetings that refer to this section

Found 2: meetings of this government whose minutes or machine transcripts name this section, or an ordinance in its history line, newest first. Found by rule from those records' own words. A reference is a pointer to another record, not a statement that the section applies or was changed.

Read this code where it is posted (city website (Revize)) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:braselton/zoning/4.8@2026-11-11-3608164919

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Braselton Zoning Ordinance, 4.8. Downtown Overlay District | Georgia Commons