A. Purpose The regulations in this section are intended to permit reasonable uses of outdoor lighting for nighttime safety, utility, security, productivity, enjoyment, and commerce;
curtail and reverse the degradation of the nighttime visual environment and the night sky; preserve the dark night sky for
astronomy; minimize glare, obtrusive light, and artificial sky glow by limiting outdoor lighting that is misdirected, excessive, or unnecessary; conserve energy and resources;
and help to protect the natural environment from the damaging effects of night lighting from man-made sources.
B. Applicability All outdoor lighting fixtures in all districts must meet the requirements of this section.
C. Exempt Lighting The following lights and lighting systems are exempt from these requirements:
1. Interior lighting
2. Lighting for pools used at night
3. Underwater lighting used for the illumination of swimming pools and fountains
4. Temporary holiday lighting
5. Lighting required and regulated by the Federal Aviation Administration, or other federal or state agency
6. Emergency lighting used by police, fire, or medical personnel, or at their direction
7. All outdoor light fixtures producing light directly from the combustion of fossil fuels, such as natural gas
8. Security lighting controlled and activated by a motion sensor device for a duration of 10 minutes or less
D. Prohibited Lighting The following lighting systems are prohibited:
1. Aerial lasers
2. Searchlight style lights (Temporary searchlights may be turned on for 8 hours within a 24-hour period and for no more
than 3 consecutive days, once each calendar year.)
3. Other very intense lighting, defined as having a light source exceeding 200,000
lumens, or intensity in any direction of 2 million candelas or more
4. Mercury vapor lamps
E. Lighting Standards
1. The level of lighting may not exceed 0.5 footcandles at the property line of any
residential district.
2. All outdoor lighting fixtures other than those listed as exempt in subsection (C) of this section must meet the following
criteria:
a. All light fixtures must be fully shielded as defined by the Illuminating
Engineering Society of North America (IESNA) and must be installed and maintained so that the shielding is effective as described in this section for fully shielded fixtures.
3. For non-residential uses, any light fixture must direct the light towards the ground and be placed in such a manner that no
light emitting surface is visible from any residential area or public/private roadway, walkway, trail, or other public way when viewed at ground level. The exception is decorative lights of a type specifically required or approved by the Town of
Braselton.
4. Strip or tube lights that outline windows, doors, roof lines, awnings, or other building features are prohibited. String lights may be used for decorative purposes as long as they do not so bright as to distract or be a nuisance to vehicular and pedestrian
traffic or adjacent property owners. String lights must be low wattage and consist of individual bulb receptacles connected by electrical wires. String lights must use clear bulbs. that produce white light only.
String lights must provide constant illumination and may not blinks or travel.
F. Specific Uses All lighting not directly associated with the specific uses designated in this subsection must conform to the lighting standards
described elsewhere in this section.
1. Outdoor sports, recreation fields, or performance areas. Lighting of outdoor
recreational facilities (public or private), such as, but not limited to, outdoor athletic fields, courts, tracks, special event or show areas must meet the following
requirements:
i. Luminaires. Facilities must utilize luminaires with minimal uplight consistent with the illumination constraints of the design. Where fully shielded fixtures are not used, acceptable luminaires must include those which are provided with internal or external glare control louvers or lenses, are installed so as to minimize uplight and offsite light trespass and glare, and are installed and maintained so as to avoid aiming more than 2.5 times the mounting height.
ii. Illuminance. All lighting installations must be designed to achieve the
illuminance levels for the activity as recommended by the Illuminating Engineering Society of North America (IESNA RP-6).
iii. Off-site spill. The installation must also limit off-site spill (off the parcel containing the sports facility) to the
maximum extent possible consistent with the illumination constraints of the design.
iv. Curfew. Field lighting for these outdoor athletic facilities must be turned off within 30 minutes after the last event of the night.
v. Setback. All light poles must be set back the greater of 50 feet or one foot for every foot in height from any right-of-way or property line of any lot with an occupied dwelling.
2. Gas station or drive-in establishment canopies and parking decks.
i. The total light output of luminaires mounted on the lower surface, or recessed into the lower surface of the canopy, and any lighting within signage or illuminated panels must not exceed 50 foot-candles.
ii. The total light output of illuminated areas other than as detailed in
subsection 2(i) above must not exceed 15 foot-candles.
iii. Illuminance levels for the interior of parking decks, where interior
lighting is visible from outside the structure, must conform to the IESNA recommendation (RP-20).
iv. Lights must not be mounted on the top or sides of a canopy and the sides of a canopy must not be illuminated.
3. Security lighting. Security lighting is lighting that provides a level of illumination to clearly identify persons or objects and
creates a psychological deterrent to unwanted or unsafe activity in the area being protected.
i. Security lighting must be directed toward the targeted area, and not adjacent properties.
ii. Sensor activated lighting must be located in such a manner as to prevent direct glare and lighting into properties of others or into a public right-of-way, and the light must not be triggered by activity off the property.
4. Architectural accent lighting.
i. Fixtures used to accent architectural features, materials, colors, style of buildings, landscaping, or art must be located, aimed and shielded so that light is directed only on those features.
Such fixtures must be aimed or shielded to minimize light spill into the dark night sky in conformance with the luminaire standards.
ii. Lighting fixtures must not generate glare or direct light beyond the facade onto a neighboring property, streets, or into the night sky.
5. Parking lots serving non-residential uses.
i. The minimum illumination level for a parking lot is 0.5 foot-candles at grade level and the ratio of the average illumination to the minimum illumination must not exceed 4:1.
ii. Floodlights must be aimed or shielded to minimize uplight.
iii. Light poles used in parking lots may not exceed 35 feet in height.