A. The following standards apply to all façades facing any street.

1. The total area of all windows on an individual story in any residential building must not be less than 10%, nor greater

than 50%, of the total façade area for that story. The total area of all windows in any building with primarily non-residential uses must not be less than 40% of the total

façade area of the ground floor, nor less than 30% of the total façade area for each upper story. Total façade area includes the area of garages and doors.

2. Doors and windows that operate as horizontal sliders are prohibited.

3. Individual windows must be vertically shaped, with a height greater than width.

4. Windows must have true or simulated divided lites or be one-over-one lites.

5. Transom windows are permitted, but do not need to be vertically shaped, have

divided lites, or include a sill.

6. Window panes must be recessed a minimum of 1 inch from the face of the façade where no trim is provided, or a minimum of 1.5 inches from the face of the trim where trim is provided.