--- title: Bremen Zoning Ordinance, Sec. 120-33. Required information for engineered construction plans collection: local-codes id: local-code:bremen/zoning/120-33 cite_as: Bremen, Ga., Zoning Ordinance § 120-33 canonical_url: https://georgiacommons.org/code/local/bremen/zoning/120-33 md_url: https://georgiacommons.org/code/local/bremen/zoning/120-33.md text_url: https://georgiacommons.org/code/local/bremen/zoning/120-33/text source_url: https://library.municode.com/ga/bremen date: 2025-10-13 status: active jurisdiction: city:bremen jurisdiction_name: Bremen place_fips: "1310132" corpus_version: local-codes-bremen-716bcd8c1e6f publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/bremen/zoning/~part-iii/~chapter-120/~article-ii.md previous: https://georgiacommons.org/code/local/bremen/zoning/120-32.md next: https://georgiacommons.org/code/local/bremen/zoning/120-34.md index: https://georgiacommons.org/code/local/bremen.md branch: zoning edition: As published by Municode, current through 2025-10-13 edition_date_kind: current_through source_publisher: Municode version_id: local-code:bremen/zoning/120-33@2025-10-13-bbf58fc4d0 --- # Bremen Zoning Ordinance, Sec. 120-33. Required information for engineered construction plans > As published by Municode, current through 2025-10-13 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part III - LAND DEVELOPMENT CODE / Chapter 120 - SUBDIVISION AND PLATTING REGULATIONS / Article II - PLATTING PROCEDURE The following information must be shown on the engineered construction plans to demonstrate compliance with applicable land development requirements: (1) Required site plan and profiles shall be drawn at a horizontal scale of 20 or 50 feet to one inch, and the vertical scale at ten feet to one inch. (2) Information required on site plan: a. Street right-of-way, street names, lot lines, and easements. b. Topography at intervals of two or five feet contour. c. Pavement widths, spot elevations, approximate street gradients and outline construction specifications. d. Spot elevations and slope ratios for any heavy grading. e. Proposed public or semipublic sites for parks, churches, and other community facilities, if any. f. Generalized storm drainage plan including catch basin locations, tentative sewer and culvert sizes, spot elevations of key system elements, final disposition of surface water, and outline construction specifications. g. Sanitary sewer system plan including line locations, depths, and sizes, manholes, elevations of key system elements, location or method of final wastewater disposal, and outline of construction specifications. h. Water system plan including line location, sizing, fire hydrants and ties into the existing city water distribution system. i. Sequence and geographic limits of construction phases proposed for large-scale development. j. Other data necessary to demonstrate that the subdivision can meet the requirements of an acceptable subdivision plat of record. k. Sidewalk locations and handicapped crossing ramps GDOT specification 9031W, when installing. l. Buffer zones and/or a buffer zone improvements plan. (3) Full size sheet shall be 24 by 36 inches. A cover sheet shall be required and shall include the name of the subdivision, subdivider, the engineer preparing the plans, with appropriate addresses for each, a vicinity map and index map. Each sheet will contain a numeric and graphic scale, date, and north arrow. Three half size and two full size sets shall be required. (4) All plans shall be clearly and legibly drawn using generally accepted techniques and conventions, with the preferred method being AutoCAD drawing or a compatible version thereof. (5) Engineering specifications shall accompany the plans to describe the installation, materials, cleaning and testing of the proposed improvements. The engineering specifications shall meet or exceed those minimum design standards set forth herein. The developer's engineer shall consider site specific conditions in their design. a. Name and address of all owners of record and of the subdividers. b. Name of the registered professional engineer responsible for the preparation of the plans. c. Exact boundary lines of the subdivision by bearings and distances and any proposed limits of construction. d. All names of proposed and existing streets in the vicinity and proposed streets must not closely resemble existing streets within the city limits. e. The location of the subdivision and developments in its immediate vicinity, including: 1. Land lot and district numbers and lines. 2. City and county names and boundary limits. 3. Names of owners of record of adjoining land. 4. Location, widths, name of owners and purpose of any existing easements. f. Location of existing buildings and other structures on the tract and any significant natural features, including trees that should be preserved. g. Scaled layout of the lots and blocks with letter or number designations. h. Labeling of all existing and proposed utilities and drainage easements is mandatory. ## History (Code 1996, § 82-85(c), (d); Ord. of 3-8-1999, pt. II, art. 9)