Civic buildings, which may be occupied only by allowed public and civic uses, are allowed in all X districts, subject to compliance with the lot and building regulations of table 3-7 (see also figure 3-2). TABLE 3-7 — CIVIC BUILDINGS Regulation MX1 MX2 CX EX a. Lot Minimum Lot Area (square feet) 6,000 6,000 6,000 6,000 Minimum Lot Width & Frontage (feet) 50 50 50 50 Maximum Impervious Coverage (%) 55 55 65 80 b. Building Siting Minimum Principal Building Setbacks (feet) Front Street 5[1] 5[1] 5[1] 30[1] Side Street 5[1] 5[1] 5[1] 15[1] Interior Side 10 10 10 10 Rear 30 30 30 30 c. Maximum Building Height Principal Building (feet) 45 45 45 45 Accessory Building (feet) 20[2] 20[2] 20[2] 20[2] TABLE 3-7 — CIVIC BUILDINGS Regulation MX1 MX2 CX EX d. Parking and Garages Permitted Location of In-Building Parking Anywhere below grade and in above-grade floors if set back at least 20 ft. from front facade Permitted Location of Surface Parking Rear yard and side yard (behind principal building setback) [1] Street-facing garage entries must be set back at least 20 feet from the back of the sidewalk or from the street right-of-way, whichever results in a greater setback. [2] Or height of principal building, whichever is less.