Part II - CODE OF ORDINANCES / Chapter 27 - ZONING / Article IX - LANDSCAPING AND SITE FEATURES / Division 4 - OUTDOOR LIGHTING

Sec. 27-983. Lighting plans.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) General. Outdoor lighting plans demonstrating compliance with applicable regulations of this division are required with the submittal of a site plan unless no new outdoor lighting is proposed on the site, in which case a note shall be placed on the face of the site plan indicating that no new outdoor lighting will be installed. Applicants have two options for the format of required outdoor lighting plans:

(1) Submit a lighting plan that complies with the fixture height lighting plan requirements of section 27-983(b); or

Figure 9-2. Shielded Light Fixtures

(2) Submit a photometric plan demonstrating that compliance will be achieved using taller fixture heights, in accordance with section 27-983(c).

(b) Option 1: Fixture height standard lighting plan. Option 1 (Fixture Height Standard Lighting Plans) establishes maximum light fixture heights but does not require submittal of a detailed photometric plan.

(1) Information required. Fixture height standard lighting plans shall include at least the following:

a. A scale drawing of the site with all outdoor lighting locations shown;

b. Fixture specifications, including catalog cut-sheets or generic standards;

c. Pole type and height of fixture;

d. Lamp type and size; and

e. Fixture mounting and orientation.

(2) Maximum fixture heights. Allowable heights of light fixtures shall be measured from the light-emitting surface to finished grade at the base of the pole. Maximum allowed light fixture heights are based on the (ground-level) horizontal distance between the light fixture and any R zoning district or public right-of-way, as established in table 9-2:

TABLE 9-2 — MAXIMUM LIGHT FIXTURE HEIGHTS

Distance from R-Zoned Lot or Public ROW (feet) Max. Fixture Height (feet) 0 - 50 16

50.01 - 250 20 More than 250 35

(c) Option 2: Photometric study. Under option two (photometric study lighting plan) no maximum fixture heights are established, but applicants are required to submit a photometric study in sufficient detail to demonstrate that all applicable outdoor lighting regulations will be met. The photometric study shall include at least the following:

(1) A scale drawing of the site with all outdoor lighting locations shown;

(2) Fixture specifications, including catalog cut-sheets or generic standards;

(3) Lamp type and size;

(4) Fixture mounting heights, mounting orientation, and tilt angles if applicable; and

(5) A representative point-by-point illumination array for the site showing property lines and demonstrating compliance with applicable light trespass limits.

History

The history line the source prints at the end of the section.

(Ord. No. RZ-2018-11-06, § I, Exh. A(27.273), 11-27-2018)