(a) District standards. Subject to the provisions of this section, buildings and structures shall not exceed the maximum heights established in the applicable zoning district's development standards. (b) Measurement. The height of a building is the vertical distance measured from the mean elevation of finished grade at the front building line or the base flood elevation to the highest point of a flat roof or parapet, the deck line of a mansard roof, or the midpoint between the ridge and the eave for a pitched roof (see building height definition for more detail). When a roof plane with the tallest ridge has dormers, height shall be based on the primary roof plane, with the dormers having no impact on height measurement unless they are higher than the highest ridge. (c) Institutional structures. The following buildings, where authorized in a zoning district, may be constructed to any height subject to Fire and Building Codes and the requirement that any portion of a structure exceeding the maximum height of the district is set back from each property line at least one foot for every one foot that that portion of the building exceeds the maximum height of the applicable zoning district: (1) Government offices; (2) Schools; (3) Libraries; and (4) Hospitals larger than 10,000 square feet of floor area. (d) Exceptions. The maximum height regulations shall not apply to: (1) Belfries, cupolas, domes, monuments, water towers, transmission towers, steeples, chimneys, smokestacks, radio towers, masts and aerials, conveyors, and fire towers. (2) Bulkheads, elevator penthouses, water tanks, cooling towers, scenery lofts and similar structures provided that such structures shall cover not more than 25 percent of the total roof area of the building on which such structure is located. (3) Heating and air conditioning equipment, solar collectors and similar equipment, fixtures and devices are exempt, provided that they are set back from the edge of the roof a minimum distance of one foot for every foot the feature extends above the roof surface. Screen or parapet walls shall be constructed to the height of any fixture taller than three feet in height that would be visible from a street or residential property abutting the property. (e) Additional rules for specific structures. (1) Towers and antennas, where allowed, are subject to the provisions of chapter 113 of the Bryan County Code. (2) Fences in the RR, R, and PD zoning districts may not exceed eight feet in height and may not exceed ten feet in height for all other districts. Additionally, in the RR, R, and PD zoning districts, the maximum height of a fence in the front yard shall be four feet. (f) Height transitions. The following provisions for height transitions are measured from property lines of parcels where multi-family, mixed-use or non-residential structures abut an arterial connector or collector road, or A-5, RR or R-15 zoning district. (1) In all districts, balconies that are located above the second story shall be setback at least 100 feet from affected property lines. (2) In a R-M district, portions of the building exceeding 35 feet shall be set back at least 100 feet from affected property lines. (3) In C-1, I-1 and I-2 districts, portions of the building exceeding 35 feet shall be setback an additional two feet from the required building setback for each foot of height in excess of 35 feet as illustrated in Exhibit 610c.