All required open space shall meet the following design criteria, as applicable: (a) Water bodies, retention areas, detention basins and wetlands basins, may constitute up to 40 percent of required open space, provided that retention facilities are designed to provide safe access to water, i.e. an observation deck, fishing pier, etc. Retention or detention areas shall be given a natural character and shall be constructed of natural materials. Terracing, berming, and contouring are required in order to naturalize and enhance the aesthetics of the basin. (b) Unless otherwise approved by the engineering director, side slopes to detention/retention facilities shall provide at least three feet of horizontal run for each foot of vertical rise. (c) Designated open space within residential development, single and multi, should be of a suitable size, location, dimension, topography and general character, and have proper road and/or pedestrian access to be usable open space. Open space provided pursuant to this requirement shall be accessible to all residents of the development and shall measure at least 30 feet across its narrowest dimension. (d) Not more than 20 percent of required open space may be used to meet the active recreational facilities requirement identified in article VI, division 7. The land area of the open space used for active recreational facilities, however, does not count toward the minimum land area required pursuant to the active recreation land minimums in section 114-645(b) and (c). All passive park land may be counted towards required open space.