Bryan County · Zoning Ordinance
Part II - CODE / Part B - LAND DEVELOPMENT / Chapter 114 / Article VI - SITE DEVELOPMENT STANDARDS / Division 9 - LIGHTING
Sec. 114-676. General standards.
About this text
- As published by Municode, current through 2026-01-13
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
All exterior lighting, excluding streetlights, shall comply with the following standards. Lighting fixtures shall be full cut-off fixtures with the light source fully shielded, with the following exceptions:
(a) Luminaires. All luminaires shall have a cutoff at 90 degrees or less and comply with the standards in Exhibit 676.
(b) Motion sensor lighting. Sensor activated lighting may be unshielded provided it is located in such a manner as to prevent direct glare and lighting into properties of others or into a public right-of-way, and provided the light is set to only go on when activated and to go off within five minutes after activation has ceased, and the light shall not be triggered by activity off the property.
(c) Non-essential and security lighting. All non-essential exterior commercial and residential lighting is encouraged to be turned off after business hours and/or when not in use. Lights on a timer are encouraged. Sensor activated lights are encouraged to replace existing lighting that is desired for security purposes.
(d) Floodlamps and area lights. All floodlamps and area lights shall be aimed downward at least 45 degrees and no portion of the light bulb shall extend below the bottom edge of an external shield. Any floodlamp or area light emitting 1,000 or more lumens shall be aimed downward at least 60 degrees. The light source of floodlamps and area lights shall not be visible from adjacent properties or the public right-of-way. Flood lights with directional shielding and photocells with timers that allow a flood light to go on at dusk and off by eleven p.m. are encouraged.
(e) Canopy lights service stations. The average lighting level for new and existing service stations shall be no greater than three lumens per square foot under the canopy. All lighting shall be recessed to ensure that no light source is visible from or causes glare on public rights-of-way or adjacent property
(f) Towers. All radio, communication and navigation towers that require lights shall have dual lighting capabilities. For daytime, the white strobe light may be used, and for nighttime lights shall be used in compliance with FAA standards and allow for the minimum impact to avian species.
Exhibit 676: Standards for Luminaires with Total Cutoffs Standard Maximum Permitted Average Maintained Illumination* Maximum Permitted Height of Light Source** Commercial and Industrial Districts
2.00 lumens per square foot
3.00 lumens per square foot 30 feet 40 feet *Measured at the property line **Measured from the ground to light source.
(g) Temporary lighting. Temporary lighting that conforms to the requirements of this UDO shall be allowed. Non-conforming temporary exterior lighting may be permitted by the community development director only after considering (1) the public and/or private benefits which will result from the temporary lighting; (2) any annoyance or safety problems that may result from the use of the temporary lighting; and (3) the duration of the temporary non-complying lighting. The applicant shall submit a detailed description of the proposed temporary noncomplying lighting to the community development director in compliance with the temporary use permit application process.
(h) Outdoor sports field/outdoor performance area lighting.
(1) These standards shall not apply to properties subject to state or federal safe lighting standards.
(2) Because of their unique requirements for nighttime visibility and their limited hours of operation, ball fields, playing fields and tennis courts are exempted from the exterior lighting standards of paragraphs (a), (b) and (c) of this section. These outdoor recreational uses must meet all other requirements of this UDO.
Example of Luminaire with Total Cutoffs
(3) The outdoor recreational uses specified above shall not exceed a maximum permitted post height of 80 feet.
(4) The outdoor recreational uses specified above may exceed a total cutoff angle of 90 degrees, provided that the luminaire is shielded to prevent light and glare spillover to adjacent right-of-way or residential property. The maximum permitted illumination at the property line shall not exceed two lumens per square foot.
(i) Lighting of outdoor display areas.
(1) Outdoor display areas shall have a maximum point of illuminance of 20 lumens per square foot.
(2) All light fixtures shall meet the IESNA definition of Cutoff Fixtures. Forward throw fixtures (type IV light distribution, as defined by the IESNA) are required within 25 feet of any public street right-of way.
History
(Ord. No. 06-2020, § 3, 12-8-2020)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.