In all areas of special flood hazard the following provisions are required:

(a) New residential construction and substantial improvements.

(1) Where base flood elevation data are available, new construction and/or substantial improvement of any residential structure or manufactured home shall have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate equalization of flood hydrostatic forces on both sides of exterior walls shall be provided in accordance with standards of subsection (c) of section 26-3.02.17.

(2) All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other services facilities shall be elevated at or above one foot above the base flood elevation.

(b) Nonresidential construction. New construction and/or the substantial improvement of any structure located in A1-30, AE, or AH zones, may be flood-proofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be water tight to one foot above the base flood elevation, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the official as set forth above and in section 26-3.01.16(g).

(c) Elevated buildings. All new construction or substantial improvements of existing structures that include any fully enclosed area located below the lowest floor formed by foundation and other exterior walls shall be designed so as to be an unfinished or flood resistant enclosure. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater.

(1) Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria:

a. Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding;

b. The bottom of all openings shall be no higher than one foot above grade;

and

c. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwater in both direction.

(2) So as not to violate the "lowest floor" criteria of this section, the unfinished or flood resistant enclosure shall only be used for parking of vehicles, limited storage of maintenance equipment used in connection with the premises, or entry to the elevated area; and

(3) The interior portion of such enclosed area shall not be partitioned or finished into separate rooms.

(d) Standards. Standards for manufactured homes and recreational vehicles where base flood elevation data are available.

(1) All manufactured homes placed, and/or substantially improved:

a. On individual lots or parcels;

b. In expansions to existing manufactured home parks or subdivisions;

c. In new and/or substantially improved manufactured home parks or subdivisions; or

d. On a site in an existing manufactured home park or subdivision where a manufactured home has incurred "substantial damage" as the result of a flood, must have the lowest floor including basement, elevated no lower than one foot above the base flood elevation.

(2) All manufactured homes placed and/or substantially improved in an existing manufactured home park or subdivision must be elevated so that:

a. The lowest floor of the manufactured home is elevated no lower than one foot above the level of the base flood elevation; or

b. The manufactured home chassis is elevated and supported by reinforced piers (or other foundation elements of at least an equivalent strength) of no less than 36 inches in height above grade;

c. All manufactured homes must be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement.

(3) All recreational vehicles placed on sites must either:

a. Be on site for fewer than 180 consecutive days;

b. Be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached structures or additions); or

c. The recreational vehicle must meet all the requirements of section 26-3.02.18(a) including the anchoring and elevation requirements of section 26-3.02.18(d)(2)c, above.

(e) Floodways. Located within areas of special flood hazard established in section 26-3.02.06 are areas designated as floodways. A floodway may be an extremely hazardous area due to velocity floodwaters, debris or erosion potential. In addition, the area must remain free of encroachment in order to allow for the discharge of the base flood without increased flood heights. Therefore, the following provisions shall apply:

(1) Encroachments are prohibited, including earthen fill, new construction, substantial improvements or other development within the regulatory floodway. Development may be permitted however, provided it is demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the encroachment shall not result in any increase in flood levels or floodway widths during a base flood discharge. A registered professional engineer must provide supporting technical data and certification thereof.

(2) Only if subsection (e)(1) above is satisfied, then any new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this section.

(Ord. No. 18-01, §§ 1, 2, 9-11-2018; Ord. No. 19-05, § 2, 8-13-2019) 26-3.02.18 Standards for areas of special flood hazard (Zones AE) with established base flood elevations without elevated floodways.

Located within the areas of special flood hazard established in section 26-3.02.06 where streams with base flood elevations are provided but no floodways have been designated (Zones AE), the following provisions apply.

(a) No encroachments, including fill material, new structures or substantial improvements shall be located within areas of special flood hazard, unless certification by a registered professional engineer is provided demonstrating that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one foot at any point within the community. The engineering certification should be supported by technical data that conforms to standard hydraulic engineering principles.

(b) New construction or substantial improvements of buildings shall be elevated or flood-proofed to elevations established in accordance with section 26-3.02.17.

(Ord. No. 18-01, §§ 1, 2, 9-11-2018; Ord. No. 19-05, § 2, 8-13-2019) 26-3.02.19 Standards for streams without established base flood elevation and/or floodways (A-Zones).

Located within the areas of special flood hazard established in section 26-3.02.06, where streams exist but where no base flood data has been provided (A-Zones), or where base flood data have been provided but a floodway has not been delineated, the following provisions apply:

(a) When base flood elevation data or floodway data have not been provided in accordance with section 26-3.02.06, then the flood plain administrator shall obtain, review, and reasonably utilize any scientific or historic base flood elevation and floodway data available from a federal, state, or other source, in order to administer the provisions of this section. ONLY if data are not available from these sources, then the following provisions (b) and (c) shall apply:

(b) No encroachments, including structures or fill material, shall be located within an area equal to the width of the stream or 20 feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge.

(c) In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three feet above the highest adjacent grade at the building site. Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of section 26-3.02.17(c).

(d) The flood plain administrator shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file.

History

The history line the source prints at the end of the section.

(Ord. No. 18-01, §§ 1, 2, 9-11-2018; Ord. No. 19-05, § 2, 8-13-2019)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:burke-county/zoning/26-3.02.17@2025-10-14-02a5af7c87

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Burke County Zoning Ordinance, 26-3.02.17. Specific standards | Georgia Commons