All preowned manufactured homes shall comply with the following before being issued a certificate of occupancy by the building inspector:
(a) HUD Code. Every pre-owned manufactured home located in the jurisdiction shall be in compliance with the Federal Manufactured Housing Construction and Safety Standards Act, 42 U.S.C. §§ 5401—5445 (the HUD Code) and shall not have been altered in such a way that the home no longer meets the HUD Code.
(b) Interior condition. Every floor, interior wall, and ceiling of a pre-owned manufactured home shall be in sound condition. Doors and windows shall be operable, watertight and in good working condition. The floor system shall be in sound condition and free of warping, holes, water damage, or deterioration.
(c) Exterior condition. The exterior of all pre-owned manufactured homes shall be free of loose or rotting boards or timbers and any other conditions that might permit rain or moisture to the interior portions of the walls or to occupied spaces. The exterior siding shall be free of rot and rust. Roofs shall be structurally sound and have no obvious defects that might permit rain or cause moisture to collect on the interior portion of the home.
(d) Sanitary facilities. Every plumbing fixture, water, and waste pipe of a pre-owned manufactured home shall be in a sanitary working condition when properly connected and shall be free from leaks and obstructions. Each home shall contain a Pt. IV, Art. I, § 1.10.D BYRON CODE
kitchen sink. Each bathroom shall contain a lavatory and water closet. At least one bathroom shall contain a tub and/or shower facilities. Each of these fixtures shall be checked upon being connected to ensure they are in good working condition.
(e) Heating systems. The heating shall be safe and in working condition. Unvented heaters shall be prohibited.
(f) Electrical systems. Electrical systems (switches, receptacles, fixtures, etc.) shall be properly installed and wired and shall be in working condition. Distribution panels shall be in compliance with the approved listing, complete with required breakers, with all unused openings covered with solid covers approved and listed for that purpose. The home shall be subject to an electrical continuity test to assure that all metallic parts are properly bonded.
(g) Hot water supply. Each home shall contain a water heater in safe and working condition.
(h) Egress windows. Each bedroom of a manufactured home shall have at least one operable window of sufficient size to allow egress if necessary.
(i) Ventilation. The kitchen in the home shall have at least one operating window or other ventilation device.
(j) Smoke detectors. Each pre-owned manufactured home shall contain one operable battery-powered smoke detector in each bedroom and in the kitchen, which must be installed in accordance with the manufacturer's recommendations.
(k) Carbon monoxide detectors. Each pre-owned manufactured home, equipped with any gas operated appliances shall contain one operable battery powered carbon monoxide detector in each bedroom and in the kitchen, which must be installed in accordance with the manufacturer's recommendations.
History
(Ord. No. 2023-12, Exh. A, 4-8-2024)