The City of Byron finds that adequate and appropriate lighting for all construction, development, and re-development promotes safety and aesthetics within the city. (a) All new construction, development, and re-development shall be required to install and maintain exterior lighting, including, but not limited to, parking lots. (b) Outdoor lighting of all types shall be directed so as not to reflect glare into residential dwellings or districts and shall be so situated as not to reflect into any public right-of-way. (c) Flashing or running lights within public view are prohibited, provided that this prohibition shall not apply to temporary holiday displays. (d) All exterior lighting should be architecturally compatible with the building style, material, and color selections. Architectural and shoebox style cutoff fixtures shall be used in all parking areas as opposed to cobra type light fixtures and directional floodlights. Exterior lighting of the building and site should be designed so that light Pt. IV, Art. I, § 1.12 BYRON CODE is not directed off the site, and the light source is shielded from direct offsite viewing. All outdoor light fixtures should be fully shielded or be designed or provided with light angle cut-offs, so as to eliminate uplighting, spill light, and glare. Exterior architectural, display, and decorative lighting visible from the designated corridors shall be generated from a concealed light source with low-level fixtures. Any lighting fixture used to illuminate parking areas, access drives or loading areas shall be of such design, so as to minimize the amount of ambient lighting perceptible from adjacent properties. In no case should any lighting impair the vision of motorists. Entrances into developments from the designated corridors may be lighted for traffic safety reasons, provided such lighting does not exceed the applicable lumens requirements specified below. Excessive illumination of signage, buildings, or site features should be avoided. Roof lighting and down-lighting washing the building walls are strongly discouraged. (e) Fixture mounting height should be appropriate for the project and the setting. The overall height of all lighting within parking lots should not exceed 30 feet in height from finish grade to the top of the light fixture. Lower mounting heights are encouraged where sites are located adjacent to residential areas or other sensitive land uses. Use of low, bollard-type fixtures that are three to four feet in height, are encouraged as pedestrian area lighting. (f) Light fixtures. All light fixtures should be a cutoff luminaire whose source is completely concealed with opaque housing and should not be visible from any street. This provision includes lights on mounted poles, as well as architectural display and decorative lighting visible from the corridor. Fixtures should be mounted in such a manner that the cone of light is not directed at any property line of the site. Only incandescent, fluorescent, metal halide, mercury vapor or color corrected highpressure sodium light may be used. The same type of lighting must be utilized for all fixtures and light sources on the site. (g) Illumination levels. All site lighting should be designed so that the level of illumination measured in lumens at any one point meets the standards below. The planning commission shall have the discretion to allow limited flexibility as to variations in the minimum and average levels if the proposed levels are below the following standards. The planning commission shall not allow flexibility for proposed levels which exceed the maximum levels unless such levels strictly conform to the recommended levels within the IESNA Lighting Handbook. Lighting underneath canopies for service stations or similar uses shall be restricted to no more than two 320-watt recessed lighting fixtures (including lenses) mounted flush with the bottom of the canopy on each side of a gasoline pump or other design that meets the standards of this chapter. Lighting for canopies for service stations and other similar uses shall not exceed an average of 129 lumen as measured at the ground level at the inside of the outside edge of the canopy. Lighting for ATM machines shall be recessed and mounted flush with the actual canopy above the ATM machine and shall comply with the latest requirements identified within the IESNA Lighting Handbook or established by federal regulations. Decorative lighting may be used only at service entrances to buildings and shall not be used to draw attention to the building or provide general building or site lighting. Wall packs on the exterior of a building shall be shielded (full cut-off type bulb or light source not visible from offsite) to direct light downward and be of low wattage (100 watts or lower). Illumination of all monument signage shall be by an externally located steady light source, which is shielded and directed solely at the sign. The intensity of the light shall not exceed 215 lumens at any one point on the sign face. Colored lamps are not permitted. (h) Electrical streetlighting. (1) Electrical streetlighting shall be installed in all subdivisions. (2) Adequate streetlighting shall be determined and approved by the city planner during the approval of a preliminary plat. One copy of the approved streetlighting plan shall be forwarded to the electrical utility company servicing the subdivision. (3) The developer shall provide adequate lighting at street intersections, and dead-end streets including cul-de-sac, and all at-grade cart paths crossing with collectors or arterial. (4) As a minimum, luminaires are to be mounted at least 16 feet above grade. As a maximum, luminaires are to be mounted not more than 28 feet above grade. Adjustment in spacing and luminaire height may be made due to street curves, topography and natural foliage and type of equipment. A design within the range of the minimum and maximum shall be considered for approval that produces the effective horizontal illumination of 2.15 lumens. (5) Poles, fixtures, and all related materials must be available standard stock items through the electric utility company servicing the subdivision or must be approved by the city planner. (6) The developer shall pay the cost of installing the streetlights to any newly built subdivision. (7) The city will accept monthly charges for streetlight units on public property after negotiation and contract with the utility company following satisfactory implementation of subsections (1) through (6) above. (i) Submittal requirements. As a part of the conceptual site plan submittal, the applicant shall be required to provide the following information to the city planner for review and distribution to the planning commission for consideration: (1) Schematic architectural elevations for all buildings or a set of design guidelines that include the unifying elements that are to be incorporated within the overall project (including each outparcel); Pt. IV, Art. I, § 1.13 BYRON CODE (2) Identification of primary physical characteristics of each building including predominant color(s), exterior materials, and architectural features; (3) Primary landscape theme (general, not specific); (4) Proposed building heights; (5) Proposed lighting plan (general); (6) Other elements which may be relevant to a specific development and how they are compatible with the adjacent sites; and (7) Signage program (general). a. Color samples shall be submitted to the planning commission as a part of the conceptual site plan review process and shall be kept on file once approved. Colored renderings may be required but shall not be a substitute for this requirement. In addition to listing the color(s), the design guidelines shall also describe how and where the color will be used. It is recognized that the same color on a different material may not match exactly. b. A lighting plan shall be required for all non-single-family residential developments of one acre or more in size. When required, lighting plans shall illustrate all proposed lighting on a site and buildings. The plan should illustrate areas of night illumination and the amount of light at various places measured in lumens. When required, the lighting plan shall consist of either lumens (connecting points of equal light illumination levels, similar to a topographic contour) or a photometric grid with individual spot readings). No lighting plan shall be approved which will result in direct light that exceeds the requirements or is otherwise inconsistent with the provisions of this section. (j) Requirements following project completion. The present owner and all subsequent owners of the property shall maintain all appearance features, lighting, and landscaping approved by the planning commission. Changes beyond the owner's control shall be restored by the owner, unless otherwise provided. Any modifications to any element of the site plan, building design or lighting initially approved by the planning commission will require subsequent review and approval by the planning commission. (Ord. No. 2023-12, Exh. A, 4-8-2024) Sec. 2. Nonconforming use.