A. Height restrictions. In addition to the height requirements identified in this UDC, all signs shall be subject to the height limitation of the district in which the sign is located, and, in event of conflict, the most stringent standard shall apply. B. Location restrictions. 1) Unless otherwise provided in this UDC, all signs shall be located on private property and in no case on public property or within the public right-of-way, private right-of-way, ingress and egress easements, driveway and maneuvering areas, or within utility easements, except with respect to swinging or projecting signs in the downtown district that meet the standards of section 103.05.10.B.3. 2) No freestanding sign may be located within 30 feet of the intersection of street right-of-way lines extended parallel or at a location that would cause an obstruction to vision of vehicular or pedestrian traffic. 3) No sign shall interfere with road or highway visibility or obstruct or otherwise interfere with the safe and orderly movement of traffic. 4) No sign shall be located on any building, structure, fence or other property belonging to another person without the consent of the owner, and as allowed under the provisions of this section. 5) All signs shall be located in such a way that they maintain horizontal and vertical clearance from all overhead utilities in accordance with National Electrical Code specification. In no case shall any sign be installed within five feet horizontally or vertically from an overhead utility line or utility guy wire. C. Setbacks. 1) Unless otherwise provided for herein, all signs shall be located outside public or private rights-of-way or at least ten feet from the back of the curb or edge of pavement of the adjacent street, whichever is greater. 2) Signs located on a corner lot shall be no closer than 30 feet from the intersection of street right-of-way lines and shall be set back outside of the public or private right-of-way, or 15 feet from the back of the curb or edge of pavement of the adjacent street, whichever is greater. D. Construction and inspection. 1) No sign shall be erected or maintained unless it is structurally safe, clean, and in good repair. 2) Except as otherwise provided in this UDC, all signs for which a permit is required shall be constructed and maintained in conformance with applicable building and electrical codes. 3) All illuminated signs shall be constructed and maintained in accordance with the requirements of the latest adopted version of the National Electrical Code. 4) All signs, together with their supports, braces, guys and anchors shall be kept in good repair and, unless constructed of galvanized or non-corroding metal, shall be given a protective coating as necessary to maintain a clean appearance and safe condition. 5) In the case of a sign with a translucent face, the material shall be a pan-molded background with embossed copy. In the case of a sign with copy less than six inches, or a sign face smaller than two feet by four feet, a pan face with flat copy may be used. In the case of a sign face larger than 100 square feet and exceeding 40 feet in height, a sign face made of flexible, reinforced material stretched over a supporting frame may be used. 6) All signs of plastic material, including copy, facing or display surface, must be in accordance with ASTM D 635 Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position. 7) All edges and backs of signs, with the exception of wall signs comprised of individual channel letters, shall be fully encased in metal or other noncombustible material. 8) All components of an illuminated sign shall be U.L. listed, or the equivalent thereof, with an identification label that shows the manufacturer of such sign. 9) Every sign may be inspected by the building official from time to time so as to determine continuing compliance with this UDC. E. Illumination. 1) No sign shall give off light which glares, blinds, or has any other such adverse effect on traffic. 2) The light from all illuminated signs shall be established in such a way that adjacent properties and roadways are not adversely affected and that the light shall not be of any intensity or brightness which will interfere with the peace, comfort, convenience and general welfare of residents or occupants of adjacent properties and roadways. 3) No illuminated sign shall be constructed or maintained within 75 feet of the property line of any single-family dwelling. 4) No series, lines or rows of electric lights shall be allowed. Bare bulb illumination and illumination of flashing or moving lights shall also be prohibited. 5) No colored lights shall be used at any location or in any manner as to be confused with, or construed as, traffic control devices. 6) Neither direct nor reflected light from primary light sources shall create a hazard to the motoring public. 7) An externally-illuminated sign, where allowed, shall have concealed wiring and controls, and shall have shielded and screened external light sources. 8) An internally-illuminated sign, where allowed, shall completely shield the source of light from direct view. F. Maintenance. 1) The owner of any sign shall be responsible for ensuring that the sign is inspected annually and in good condition. 2) Every sign, including those specifically exempt from this section with respect to permits and permit fees, shall be maintained in good structural condition at all times. 3) All signs shall be neatly painted, including all metal parts and supports thereof that are not galvanized or of rust resistant material. 4) The director shall have the authority to inspect all signs and to issue a citation or order the repainting, repair, alteration, or removal or a sign which shall constitute a hazard to public safety, health or general welfare by reason of inadequate maintenance, dilapidation, or obsolescence. 5) No sign face shall be obscured by landscaping or vegetation.