--- title: Canton Zoning Ordinance, 107.03.04. Administration collection: local-codes id: local-code:canton/zoning/107.03.04 cite_as: Canton, Ga., Zoning Ordinance ยง 107.03.04 canonical_url: https://georgiacommons.org/code/local/canton/zoning/107.03.04 md_url: https://georgiacommons.org/code/local/canton/zoning/107.03.04.md text_url: https://georgiacommons.org/code/local/canton/zoning/107.03.04/text source_url: https://library.municode.com/ga/canton date: 2026-11-11 status: active jurisdiction: city:canton jurisdiction_name: Canton place_fips: "1312988" corpus_version: local-codes-canton-bb716bdc4821 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/canton/zoning/~part-iii/~chapter-107.md previous: https://georgiacommons.org/code/local/canton/zoning/107.03.03.md next: https://georgiacommons.org/code/local/canton/zoning/107.03.05.md index: https://georgiacommons.org/code/local/canton.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:canton/zoning/107.03.04@2026-11-11-d476dcb493 --- # Canton Zoning Ordinance, 107.03.04. Administration > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part III - DEVELOPMENT CODE / Chapter 107 - TABLE OF CONTENTS A. The city engineer is hereby designated the floodplain manager. This designation authorizes the city engineer to administer and implement the provisions of this section. B. The duties of the city engineer shall include, but shall not be limited to, the following: 1) Review all development applications and permits to assure that the requirements of this section have been satisfied and to determine whether proposed building sites will be reasonably safe from flooding; 2) Require that copies of all necessary permits from governmental agencies from which approval is required by federal or state law, including, but not limited to, section 404 of the Federal Water Pollution Control Act Amendments of 1972, 33 U.S.C. 1334, be provided and maintained on file; 3) When base flood elevation data or floodway data have not been provided, then the floodplain manager shall require the applicant to obtain, review and reasonably utilize any base flood elevation and floodway data available from a federal, state or other sources in order to meet the provisions of sections 107.03.08 and 107.03.09; 4) Review and record the actual elevation in relation to mean sea level(or highest adjacent grade) of the lowest floor, including basement, of all new or substantially improved structures; 5) Review and record the actual elevation, in relation to mean sea level to which any substantially improved structures have been floodproofed; 6) When floodproofing is utilized for a nonresidential structure, the floodplain manager shall obtain certification of design criteria from a registered professional engineer or architect; 7) Notify affected adjacent communities and the Georgia Department of Natural Resource (GA DNR) prior to any alteration or relocation of a watercourse and submit evidence of such notification to the Federal Emergency Management Agency (FEMA); 8) Where interpretation is needed as to the exact location of boundaries of the areas of special flood hazard (e.g., where there appears to be a conflict between a mapped boundary and actual field conditions) the floodplain manager shall make the necessary interpretation. a. Any person contesting the location of the boundary shall be given a reasonable opportunity to appeal the interpretation as provided in this section. b. Where floodplain elevations have been defined, the floodplain shall be determined based on flood elevations rather than the area graphically delineated on the floodplain maps. 9) All records pertaining to the provisions of this section shall be maintained in the office of the city engineer and shall be open for public inspection. 10) Coordinate all FIRM revisions with the GA DNR and FEMA; and 11) Review variance applications and make recommendations to the board of construction adjustments and appeals. ## History (Ord. No. 2019-1121-03, 11-21-2019)