--- title: Canton Zoning Ordinance, 107.03.07. Permit procedures and requirements collection: local-codes id: local-code:canton/zoning/107.03.07 cite_as: Canton, Ga., Zoning Ordinance ยง 107.03.07 canonical_url: https://georgiacommons.org/code/local/canton/zoning/107.03.07 md_url: https://georgiacommons.org/code/local/canton/zoning/107.03.07.md text_url: https://georgiacommons.org/code/local/canton/zoning/107.03.07/text source_url: https://library.municode.com/ga/canton date: 2026-11-11 status: active jurisdiction: city:canton jurisdiction_name: Canton place_fips: "1312988" corpus_version: local-codes-canton-bb716bdc4821 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/canton/zoning/~part-iii/~chapter-107.md previous: https://georgiacommons.org/code/local/canton/zoning/107.03.06.md next: https://georgiacommons.org/code/local/canton/zoning/107.03.08.md index: https://georgiacommons.org/code/local/canton.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:canton/zoning/107.03.07@2026-11-11-10f67c16d9 --- # Canton Zoning Ordinance, 107.03.07. Permit procedures and requirements > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part III - DEVELOPMENT CODE / Chapter 107 - TABLE OF CONTENTS A. Permit application requirements. 1) No permit will be approved for any development activities that do not meet the requirements, restrictions and criteria of this section. 2) Unless specifically excluded by this section, any landowner or developer desiring a permit for a development activity shall submit to the city a permit application on a form provided by the city for that purpose. B. Floodplain management plan requirements. An application for a development project with any area of special flood hazard located on the site will be required to include a floodplain management/flood damage prevention plan. This plan shall include the following items: 1) Site plan drawn to scale, which includes, but is not limited to: a. Existing and proposed elevations of the area in question and the nature, location and dimensions of existing and/or proposed structures, earthen fill placement, amount and location of excavation material, and storage of materials or equipment; b. For all proposed structures, spot ground elevations at building corners and 20-foot or smaller intervals along the foundation footprint, or one-foot contour elevations throughout the building site; c. Proposed locations of water supply, sanitary sewer, and utilities; d. Proposed locations of drainage and stormwater management facilities; e. Proposed grading plan; f. Base flood elevations and future-conditions flood elevations; g. Boundaries of the base flood floodplain and future-conditions floodplain; h. If applicable, the location of the floodway; and i. Certification of the above by a registered professional engineer or surveyor. 2) Building and foundation design detail, including, but not limited to: a. Elevation in relation to mean sea level (or highest adjacent grade) of the lowest floor, including basement, of all proposed structures; b. Elevation in relation to mean sea level to which any non-residential structure will be floodproofed; c. Certification that any proposed non-residential floodproofed structure meets the criteria in section 107.03.09.B.2; d. For enclosures below the base flood elevation, location and total net area of foundation openings as required in section 107.03.09.A.5; e. Design plans certified by a registered professional engineer or architect for all proposed structure(s). 3) Description of the extent to which any watercourse will be altered or relocated as a result of the proposed development. 4) Hard copies and digital files of computer models, if any, copies of work maps, comparison of pre- and post-development conditions base flood elevations, future-conditions flood elevations, flood protection elevations, special flood hazard areas and regulatory floodway widths, flood profiles and all other computations and other information similar to that presented in the FIS. 5) Copies of all applicable state and federal permits necessary for proposed development. 6) All appropriate certifications required under this section. a. The approved floodplain management/flood damage prevention plan shall contain certification by the applicant that all development activities will be done according to the plan or previously approved revisions. b. Any and all development permits and/or use and occupancy certificates or permits may be revoked at any time if the construction and development activities are not in strict accordance with approved plans. c. Floodplain management, flood damage prevention plan engineer's certification: "I certify that this plan was prepared by me or under my direct supervision and that all applicable federal, state, and local codes and ordinances have been met. The proposed improvements shown hereon have been designed to prevent fold damage and any adverse effects to adjacent property owners. ___________________________________________________________________ Ga. Registered Professional Engineer Date" C. Construction stage submittal requirements. 1) For all new construction and substantial improvements on sites which require a floodplain management/ flood damage prevention plan, the permit holder shall provide to the floodplain manager a certified as-built elevation certificate or floodproofing certificate for nonresidential construction including the lowest floor elevation or floodproofing level immediately after the lowest floor or floodproofing is completed. 2) A final elevation certificate shall be provided after completion of construction including final grading of the site. a. Any lowest-floor certification made relative to mean sea level shall be prepared by or under the direct supervision of a registered land surveyor or professional engineer and certified by same. b. When floodproofing is utilized for non-residential structures, said certification shall be prepared by or under the direct supervision of a professional engineer or architect and certified by same using the FEMA floodproofing certificate. 3) The floodplain manager shall review the above referenced certification data submitted. a. Deficiencies detected by such review shall be corrected by the permit holder immediately and prior to further work being allowed to proceed. b. Any work undertaken prior to approval of these certifications shall be at the permit holder's risk. 4) Failure to submit certification or failure to make the corrections required hereby shall be cause to issue a stop work order for the project. ## History (Ord. No. 2019-1121-03, 11-21-2019)