107.03.09. Provisions for flood damage reduction.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. General standards. In all areas of special flood hazard the following provisions shall apply:
1) New construction of principal buildings (residential or nonresidential), including manufactured homes, shall not be allowed within the limits of the future-conditions floodplain, unless all requirements of subsections 107.03.08.C, D, and E above have been met.
2) New construction or substantial improvements of existing structures shall be anchored to prevent flotation, collapse or lateral movement of the structure.
3) New construction or substantial improvements of existing structures shall be constructed with materials and utility equipment resistant to flood damage.
4) New construction or substantial improvements of existing structures shall be constructed by methods and practices that minimize flood damage.
5) Elevated buildings.
a. All new construction and substantial improvements of existing structures that include any fully enclosed area located below the lowest floor formed by foundation and other exterior walls shall be designed so as to be an unfinished and flood resistant enclosure. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater.
b. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria:
i. Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding;
ii. The bottom of all openings shall be no higher than one foot above grade; and iii. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwater in both directions.
c. So as not to violate the "lowest floor" criteria of this section, the unfinished and flood-resistant enclosure shall solely be used for parking of vehicles, limited storage of maintenance equipment used in connection with the premises, or entry to the elevated area.
d. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms.
6) All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be designed and/or located three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher, so as to prevent water from entering or accumulating within the components during conditions of flooding.
7) Manufactured homes shall be anchored to prevent flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces.
8) All proposed development shall include adequate drainage and stormwater management facilities per the requirements of this UDC to reduce exposure to flood hazards.
9) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system.
10) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters.
11) On-site waste disposal systems shall be located and constructed to avoid impairment to them, or contamination from them, during flooding.
12) Other public utilities such as gas and electric systems shall be located and constructed to avoid impairment to them, or public safety hazards from them, during flooding.
13) Any alteration, repair, reconstruction or improvement to a structure which is not compliant with the provisions of this section, shall be undertaken only if the non-conformity is not furthered, extended or replaced.
14) If the proposed development is located in multiple flood zones or multiple base flood elevations cross the proposed site, the higher or more restrictive base flood elevation or future-condition elevation and development standards shall take precedence.
15) When only a portion of a proposed structure is located within a flood zone or the future conditions floodplain, the entire structure shall meet the requirements of this section.
16) Subdivision proposals and other proposed new development, including manufactured home parks or subdivisions, shall be reasonably safe from flooding:
a. All such proposals shall be consistent with the need to minimize flood damage within the flood-prone area;
b. All public utilities and facilities, such as sewer, gas, electrical, and water systems shall be located and constructed to minimize or eliminate flood damage; and
c. Adequate drainage shall be provided to reduce exposure to flood hazards.
B. Building standards, future conditions-floodplain. The following provisions, in addition to those in section
107.03.09. A above shall apply to structures and buildings within the future-conditions floodplain:
1) Residential buildings.
a. New construction. New construction of principal buildings, including manufactured homes, shall not be allowed within the limits of the future-conditions floodplain unless all requirements of subsections 107.03.08.C, D, and E above have been met. In addition:
i. If all of the requirements of subsections 107.03.08.C, D, and E above have been met, all new construction shall have the lowest floor, including basement, elevated no lower than three feet above the base flood elevation or one-foot above the future-conditions flood elevation, whichever is higher.
ii. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to equalize the hydrologic flood forces on exterior walls and to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of subsection 107.03.09.A.5.
b. Substantial improvements. Substantial improvements of principal buildings, including manufactured homes, shall not be allowed within the limits of the future-conditions floodplain unless all requirements of subsections 107.03.08.C, D, and E above have been met. In addition:
i. If all of the requirements of subsections 107.03.08.C, D, and E above have been met, all substantial improvements shall have the lowest floor, including basement, elevated no lower than three feet above the base flood elevation or one-foot above the future-conditions flood elevation, whichever is higher.
ii. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to equalize the hydrologic flood forces on exterior walls and to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of subsection 107.03.09.A.5.
2) Nonresidential buildings.
a. New construction. New construction of principal buildings, including manufactured homes shall not be allowed within the limits of the future-conditions floodplain unless all requirements of subsections 107.03.08.C, D, and E above have been met. If all of the requirements of subsections 107.03.08.C, D, and E above have been met, all new construction shall have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation or at least as high as the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls shall be provided in accordance with standards of subsection 107.03.09.A.5. In addition:
i. New construction that has met all of the requirements of subsections 107.03.08.C, D, and E above may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to one foot above the base flood elevation, or at least as high as the future-conditions flood elevation, whichever is higher, with walls substantially impermeable to the passage of water and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy.
ii. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the floodplain manager using the FEMA floodproofing certificate along with the design and operation/maintenance plan.
b. Substantial improvements. Substantial improvement of principal buildings, including manufactured homes shall not be allowed within the limits of the future-conditions floodplain unless all requirements of subsections 107.03.08.C, D, and E above have been met. If all of the requirements of subsections 107.03.08.C, D, and E above have been met, all substantial improvements shall have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation or at least as high as the future-conditions flood elevation, whichever is higher.
Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls shall be provided in accordance with standards of subsection 107.03.09.A.5. In addition:
i. Substantial improvements that have met all of the requirements of subsections 107.03.08.C, D, and E above may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to one foot above the base flood elevation, or at least as high as the future-conditions flood elevation, whichever is higher, with walls substantially impermeable to the passage of water and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy.
ii. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the floodplain manager using the FEMA floodproofing certificate along with the design and operation/maintenance plan.
3) Standards for accessory structures and facilities.Accessory structures and facilities (i.e., barns, sheds, gazebos, detached garages, parking lots, recreational facilities and other similar nonhabitable structures and facilities) which are permitted to be located within the limits of the floodplain shall be constructed of flood-resistant materials and designed to pass all floodwater in accordance with subsection 107.03.09A.5 and be anchored to prevent flotation, collapse or lateral movement of the structure.
4) Standards for recreational vehicles. All recreational vehicles placed on sites must either:
a. Be on the site for fewer than 180 consecutive days and be fully licensed and ready for highway use, (a recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached structures or additions); or
b. The recreational vehicle must meet all the requirements for residential buildings—substantial improvements under section 107.03.09 (see subsection B), including the anchoring and elevation requirements.
5) Standards for manufactured homes.
a. New and substantially improved manufactured homes shall not be allowed to be placed within the limits of the future-conditions floodplain unless all requirements of subsections 107.03.08.C, D, and E above have been met. If all of the requirements of subsections 107.03.08.C, D, and E above have been met, all new construction and substantial improvements shall have the lowest floor, including basement, elevated no lower than three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls shall be provided in accordance with standards of subsection 107.03.09A.5.
b. Manufactured homes placed and/or substantially improved in an existing manufactured home park or subdivision shall be elevated so that either:
i. The lowest floor of the manufactured home is elevated no lower than three feet above the level of the base flood elevation, or one foot above the future-conditions flood elevation, whichever is higher; or
ii. The manufactured home chassis is elevated and supported by reinforced piers (or other foundation elements of at least an equivalent strength) of no less than 36 inches in height above grade.
c. All manufactured homes must be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement in accordance with standards of subsection 107.03.09.A.7.
C. Building standards, adjacent to future-conditions floodplain. The following provisions shall apply to structures and buildings authorized adjacent to the future-conditions floodplain:
1) Residential buildings. For new construction or substantial improvement of any principal residential building or manufactured home, the elevation of the lowest floor, including basement and access to the building, shall be at least three feet above the base flood elevation or one foot above the futureconditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls shall be provided in accordance with standards of subsection 107.03.09.A.5.
2) Nonresidential buildings. For new construction or substantial improvement of any principal nonresidential building, the elevation of the lowest floor, including basement and access to the building, shall be at least one foot above the level of the base flood elevation or at least as high as the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls shall be provided in accordance with standards of subsection 107.03.09.A.5. Non-residential buildings may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to one foot above the base flood elevation, or at least as high as the future-conditions flood elevation, whichever is higher, with walls substantially impermeable to the passage of water and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the floodplain manager using the FEMA floodproofing certificate along with the design and operation/maintenance plan.
D. Building standards, residential single-lot developments on streams without established base flood elevations and/or floodway (A-zones).
1) For a residential single-lot development not part of a subdivision that has areas of special flood hazard, where streams exist but no base flood data have been provided (A-zones), the floodplain manager shall review and reasonably utilize any available scientific or historic flood elevation data, base flood elevation and floodway data, or future-conditions flood elevation data available from a federal, state, local or other source, in order to administer the provisions and standards of this section.
2) If data are not available from any of these sources, the following provisions shall apply:
a. No encroachments, including structures or fill material, shall be located within an area equal to twice the width of the stream or 50 feet from the top of the bank of the stream, whichever is greater.
b. In special flood hazard areas without base flood or future-conditions flood elevation data, new construction and substantial improvements shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three feet above the highest adjacent grade at the building site. Flood openings sufficient to facilitate automatic equalization of hydrostatic flood forces shall be provided for flood prone enclosures in accordance with subsection 107.03.09.A.5.
3) The applicant may be required to submit a flood study prepared by a professional engineer registered with the State of Georgia.
E. Building standards, areas of shallow flooding (AO-zones). Areas of special flood hazard may include designated "AO" shallow flooding areas. These areas have base flood depths of one to three feet above ground, with no clearly defined channel. In these areas the following provisions shall apply:
1) New and substantial improvements of residential and nonresidential structures shall have the lowest floor, including basement, elevated to no lower than one-foot above the flood depth number in feet specified on the FIRM, above the highest adjacent grade.
a. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least three feet above the highest adjacent grade.
b. Openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of subsection 107.03.09.A.5.
2) New and substantial improvements of a nonresidential structure may be floodproofed in lieu of elevation.
a. The structure, together with attendant utility and sanitary facilities, must be designed to be water tight to the specified FIRM flood level plus one-foot above the highest adjacent grade, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy.
b. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice, and shall provide such certificate to the floodplain manager using the FEMA floodproofing certificate along with the design and operation/maintenance plan.
3) Drainage paths shall be provided to guide floodwater around and away from any proposed structure.
F. Standards for subdivisions.
1) All subdivision proposals shall identify the special flood hazard area and areas of future-conditions flood hazards therein and provide base flood elevation data and future-conditions flood elevation data.
2) All residential lots in a subdivision proposal shall have sufficient buildable area outside of the future-conditions floodplain such that encroachments into the future-conditions floodplain for residential structures will not be required.
3) All subdivision plans shall state the minimum L.F.E. (lowest floor elevation) of proposed structures. See also the elevation requirements in section 107.03.07.B.
4) All subdivision proposals shall be consistent with the need to minimize flood damage.
5) All subdivision proposals shall have public utilities and facilities such as water, sanitary sewer, gas, and electrical systems located and constructed to minimize or eliminate infiltration of flood waters, and discharges from the systems into flood waters.
6) All subdivision proposals shall include adequate drainage and stormwater management facilities per the requirements of City of Canton to reduce potential exposure to flood hazards.
History
(Ord. No. 2019-1121-03, 11-21-2019)