A. Where adequate access for firefighting equipment or where water supply for firefighting are not available, in the opinion of the community development director as may be informed by the fire safety services manager, an approved automatic fire sprinkler system in compliance with the applicable state plumbing code shall be required and installed for all occupied buildings prior to occupancy of said buildings. This provision shall not apply to gazebos, storage sheds or other detached accessory structures not intended for occupancy. B. Adjacent to residences or structures to be occupied, in areas of high risk of forest fires as determined by the fire safety services manager, there shall be required a clear zone of no less than 20 feet on all sides of said residences or structures, or to the property line, whichever is nearer. 1) Within the clear zone, all brush, flammable vegetation or combustible growth shall be removed. 2) This provision shall not apply to single specimens of trees, ornamental shrubbery or similar plants used as ground cover, provided that they do not form a continuous means of rapidly transmitting fire from the native growth to a residence or structure to be occupied. C. In areas of high risk of forest fires as determined by the fire safety services manager, the following provisions may be made a condition of development or permit approval: 1) Roofs shall be covered with noncombustible materials, such as clay or concrete shake or tile. 2) Exterior walls shall be surfaced with noncombustible or fire-resistant materials. 3) Chimneys shall be provided with approved spark arresters.