A. Any wall that exceeds a height of four feet along any portion of the wall shall require a separate wall permit. B. Walls exceeding 30 inches in height shall be required to have a guardrail. For guardrail design use the requirements as shown in the Deck Construction Guide as shown in the International Residential Code. Special consideration will be given to forego the guardrail requirement if one of the following criteria are met: 1) Wall is a double tier wall, with upper wall being no more than five foot from lower wall. Railings will be required to limit access to lower tier. 2) Walls no more than 40 inches in height if a non-walkable surface is in place. Non-walkable minimum is five foot of ground cover that does not require maintenance and a constant planting of at least 30 inches in height. 3) Walls no more than 48 inches tall that are the bottom of a slope over 3:1. C. An engineer's letter approving the structural safety of any wall exceeding four feet in height must be provided prior to receiving a certificate of occupancy. (Ord. No. 2018-0920-02, 9-20-2018; Ord. No. 2022-0317-01, 3-17-2022) 107.09.00 Soil erosion, sedimentation and pollution control.*