A. Concrete curb and gutter shall be required for all paved streets. B. Residential subdivision curb and gutter may be either vertical faced or rollback. 1) Residential subdivision vertical faced and rollback curbing shall have a typical minimum section of six inches by 24 inches by 12 inches. 2) The concrete shall have a minimum compressive strength of 3,000 PSI at 28 days. 3) Vertical faced curb and gutter shall be used at all subdivision entrances, deceleration lanes and downhill culs-de-sac. 4) See standard detail 207 "Curb and Gutter Cross Sections." C. Non-residential subdivision curb and gutter may be either vertical faced or rollback. 1) Non-residential subdivision vertical faced curbing shall have a typical minimum section of six inches by 24 inches by 12 inches. 2) Non-residential subdivision rollover curbing shall have a typical minimum section of six inches by 24 inches by nine inches. 3) The concrete shall have a minimum strength of 3,000 PSI at 28 days. 4) See standard detail 207 "Curb and Gutter Cross Sections." D. Parallel curb lines shall be at the same elevation on each side of the street at the same station except for intersections and approved super-elevated sections. E. One-half-inch expansion joints or pre-molded bituminous expansion joint material shall be provided at all structures and radius points and at intervals not to exceed 500 feet in the remainder of the curb and gutter. Provide construction joints at intervals not to exceed 20 feet. F. Cracks in the concrete are permissible provided that there is no vertical or horizontal displacement. The development inspector shall determine when cracked curb shall be replaced by the developer. G. Graded aggregate base shall be placed under the curb and gutter for all roadways.